🇵🇱 Instytut Medycyny Pracy im. prof. dr med. Jerzego Nofera PL

PCA AP 075 • Łódź, Poland • 4 calibration items

Metrology & calibration

Instytut Medycyny Pracy im. prof. dr med. Jerzego Nofera is a calibration laboratory accredited by PCA under number AP 075 (Łódź, Poland). Its accreditation scope covers 4 calibration items in the following areas: Metrology & calibration. Calibrated items include: Dosimetric instruments for X and gamma radiation measurement, Ionising radiation dosimeters, Film dosimeters, Ionising radiation rate meters. Most frequently used calibration principles: Internal procedure; Mean X-ray energy range 15 keV to 62 keV for ra…, Internal procedure; 24 keV to 250 keV for N and W series radiation…, Internal procedure; Mean X-ray energy in the range 15 keV to 250 ke….

At a glance

  • Accreditation number: PCA AP 075
  • Calibration items in scope: 4
  • Types of calibrated items: 6
  • Calibration principles used: 3
  • City: Łódź, Poland
  • Valid until: 19-05-2029
Accreditation number
AP 075
Accreditation body
PCA
Address
ul. Św. Teresy od Dzieciątka Jezus 8, 91-348 Łódź
City
Łódź, Poland
Division
Laboratorium Wzorców Wtórnych
Valid until
19-05-2029

What this laboratory calibrates (6)

Calibration principles (3)

Certificate information

Issue date
28.04.2025
Issue no.
19
Certificate date
07.02.2025
Accreditation cycle
28.04.2025 — 19.05.2029
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (4)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The value expressed as a percentage is a relative measurement uncertainty and refers to a percentage contribution in the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Dosimetric instruments for X and gamma radiation measurement Calibration — DC voltage
X-ray tube high voltage (for total system filtration 2,5 mmAl to 4,5 mmAl, general diagnostic range) — 40 kV to 125 kV · CMC 3,2 % X-ray tube high voltage (for total system filtration 30 μmMo + 1mmBe, mammography range) — 23 kV to 35 kV · CMC 3,2 %
DC voltage
Internal procedure; Mean X-ray energy range 15 keV to 62 keV for radiation spectra used in X-ray diagnostics; At permanent location (S) ZRW-PW-02 w oparciu o PN-EN 61676:2003
2 Dosimetric instruments for X and gamma radiation measurement Calibration — Time (time interval)
X-ray exposure time — 10 ms to 4 s · CMC 2,2 %
Time (time interval)
Internal procedure; Mean X-ray energy range 15 keV to 62 keV for radiation spectra used in X-ray diagnostics; At permanent location (S) ZRW-PW-02 w oparciu o PN-EN 61676:2003
3 Dosimetric instruments for X and gamma radiation measurement
Ionising radiation rate meters
Ionising radiation dosimeters
Calibration — Dosimetric quantities
air kerma rate — 10 μGy/h to 10 Gy/h · CMC 5 % absorbed dose rate in air — 10 μGy/h to 10 Gy/h · CMC 5 % ambient dose equivalent rate — 10 μSv/h to 10 Sv/h · CMC 5 % directional dose equivalent rate — 10 μSv/h to 10 Sv/h · CMC 5 % exposure rate — 1 mR/h to 1000 R/h · CMC 5 % air kerma — 0,1 μGy to 10 Gy · CMC 5 % absorbed dose in air — 0,1 μGy to 10 Gy · CMC 5 % ambient dose equivalent — 0,1 μSv to 10 Sv · CMC 5 % directional dose equivalent — 0,1 μSv to 10 Sv · CMC 5 % exposure — 10 μR to 1000 R · CMC 5 %
Dosimetric quantities
Internal procedure; Mean X-ray energy in the range 15 keV to 250 keV; 15 keV to 93 keV for radiation spectra used in X-ray diagnostics; At permanent location (S) ZRW-PW-01 w oparciu o PN-EN 61267:2006
4 Film dosimeters
Personal dosimeters
Thermoluminescent dosimeters
Ionising radiation dosimeters
Calibration — Dosimetric quantities
air kerma — 0,1 μGy to 10 Gy · CMC 2,3 % absorbed dose in air — 0,1 μGy to 10 Gy · CMC 2,3 % ambient dose equivalent — 0,1 μSv to 10 Sv · CMC 2,3 % directional dose equivalent — 0,1 μSv to 10 Sv · CMC 2,3 %
Dosimetric quantities
Internal procedure; 24 keV to 250 keV for N and W series radiation spectra; At permanent location (S) ZRW-PW-01 w oparciu o PN-EN ISO 4037:2021-07

Reference standards (5)

PN-EN 61267:2006
PN-EN 61676:2003
PN-EN ISO 4037:2021-07
ZRW-PW-01
ZRW-PW-02

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20075