🇵🇱 Wojskowy Instytut Chemii i Radiometrii PL

PCA AP 073 • Warszawa, Poland • 4 calibration items

Metrology & calibration

Wojskowy Instytut Chemii i Radiometrii is a calibration laboratory accredited by PCA under number AP 073 (Warszawa, Poland). Its accreditation scope covers 4 calibration items in the following areas: Metrology & calibration. Calibrated items include: Personal dosimeters, Dosimetric instruments for gamma radiation measurement, Dosimetric instruments for X-ray radiation measurement. Most frequently used calibration principles: Internal procedure; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 073
  • Calibration items in scope: 4
  • Types of calibrated items: 3
  • Calibration principles used: 1
  • City: Warszawa, Poland
  • Valid until: 16-01-2029
Accreditation number
AP 073
Accreditation body
PCA
Address
Al. Gen. A. Chruściela "Montera" 105, 00-910 Warszawa
City
Warszawa, Poland
Division
Laboratorium Badawcze Radiometrów
Valid until
16-01-2029

What this laboratory calibrates (3)

Calibration principles (1)

Certificate information

Issue date
21.11.2025
Issue no.
16
Certificate date
02.12.2019
Accreditation cycle
18.12.2024 — 16.01.2029
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (4)

The measurement uncertainty value for CMC expressed as a percentage is the relative measurement uncertainty and refers to the percentage share in the measured value. The current limits of the measurement ranges and the corresponding CMC uncertainty values, which change with the activity of the radioactive sources used, are available on request from the accredited body.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Dosimetric instruments for gamma radiation measurement Calibration — Dosimetric quantities
air kerma rate (Cs-137) — 0,4 μGy/h to 100 Gy/h · CMC 2,4 % air kerma rate (Co-60) — 1,4 mGy/h to 40 Gy/h · CMC 2,4 % exposure rate (Cs-137) — 50 μR/h to 10 kR/h · CMC 4,6 % exposure rate (Co-60) — 0,2 R/h to 4,5 kR/h · CMC 4,6 % absorbed dose rate in air (Cs-137) — 0,4 μGy/h to 100 Gy/h · CMC 4,6 % absorbed dose rate in air (Co-60) — 1,4 mGy/h to 40 Gy/h · CMC 4,6 % ambient dose equivalent rate (Cs-137) — 0,5 μSv/h to 120 Sv/h · CMC 4,6 % ambient dose equivalent rate (Co-60) — 1,6 mSv/h to 120 Sv/h · CMC 4,6 % personal dose equivalent rate (Cs-137) — 0,5 μSv/h to 120 Sv/h · CMC 4,6 % personal dose equivalent rate (Co-60) — 1,6 mSv/h to 120 Sv/h · CMC 4,6 % air kerma (Cs-137) — 0,5 μGy to 100 Gy · CMC 2,4 % air kerma (Co-60) — 0,5 μGy to 100 Gy · CMC 2,4 % exposure (Cs-137) — 50 μR to 1000 R · CMC 4,6 % exposure (Co-60) — 50 μR to 1000 R · CMC 4,6 % absorbed dose (Cs-137) — 0,5 μGy to 100 Gy · CMC 4,6 % absorbed dose (Co-60) — 0,5 μGy to 100 Gy · CMC 4,6 % ambient dose equivalent (Cs-137) — 0,5 μSv to 100 Sv · CMC 4,6 % ambient dose equivalent (Co-60) — 0,5 μGy to 100 Gy · CMC 4,6 % personal dose equivalent (Cs-137) — 0,5 μSv to 100 Sv · CMC 4,6 % personal dose equivalent (Co-60) — 0,5 μGy to 100 Gy · CMC 4,6 %
Dosimetric quantities
Internal procedure; At permanent location (S) PW-1
2 Personal dosimeters Calibration — Dosimetric quantities
air kerma rate (Cs-137) — 0,4 μGy/h to 100 Gy/h · CMC 2,4 % air kerma rate (Co-60) — 1,4 mGy/h to 40 Gy/h · CMC 2,4 % exposure rate (Cs-137) — 50 μR/h to 10 kR/h · CMC 4,6 % exposure rate (Co-60) — 0,2 R/h to 4,5 kR/h · CMC 4,6 % absorbed dose rate in air (Cs-137) — 0,4 μGy/h to 100 Gy/h · CMC 4,6 % absorbed dose rate in air (Co-60) — 1,4 mGy/h to 40 Gy/h · CMC 4,6 % ambient dose equivalent rate (Cs-137) — 0,5 μSv/h to 120 Sv/h · CMC 4,6 % ambient dose equivalent rate (Co-60) — 1,6 mSv/h to 120 Sv/h · CMC 4,6 % personal dose equivalent rate (Cs-137) — 0,5 μSv/h to 120 Sv/h · CMC 4,6 % personal dose equivalent rate (Co-60) — 1,6 mSv/h to 120 Sv/h · CMC 4,6 % air kerma (Cs-137) — 0,5 μGy to 100 Gy · CMC 2,4 % air kerma (Co-60) — 0,5 μGy to 100 Gy · CMC 2,4 % exposure (Cs-137) — 50 μR to 1000 R · CMC 4,6 % exposure (Co-60) — 50 μR to 1000 R · CMC 4,6 % absorbed dose (Cs-137) — 0,5 μGy to 100 Gy · CMC 4,6 % absorbed dose (Co-60) — 0,5 μGy to 100 Gy · CMC 4,6 % ambient dose equivalent (Cs-137) — 0,5 μSv to 100 Sv · CMC 4,6 % ambient dose equivalent (Co-60) — 0,5 μGy to 100 Gy · CMC 4,6 % personal dose equivalent (Cs-137) — 0,5 μSv to 100 Sv · CMC 4,6 % personal dose equivalent (Co-60) — 0,5 μGy to 100 Gy · CMC 4,6 %
Dosimetric quantities
Internal procedure; At permanent location (S) PW-1, PP-2
3 Dosimetric instruments for X-ray radiation measurement Calibration — Dosimetric quantities
air kerma rate — 1 μGy/h to 14 mGy/h · CMC 2,4 % exposure rate — 0,1 μR/h to 1,6 mR/h · CMC 4,6 % absorbed dose rate in air — 1 μGy/h to 14 mGy/h · CMC 4,6 % ambient dose equivalent rate — 1,2 μSv/h to 17 mSv/h · CMC 4,6 % personal dose equivalent rate — 1,2 μSv/h to 17 mSv/h · CMC 4,6 % air kerma — 0,5 μGy to 10 Gy · CMC 2,4 % exposure — 0,5 μR to 1000 R · CMC 4,6 % absorbed dose — 0,5 μGy to 10 Gy · CMC 4,6 % ambient dose equivalent — 0,5 μSv to 10 Sv · CMC 4,6 % personal dose equivalent — 0,5 μSv to 10 Sv · CMC 4,6 %
Dosimetric quantities
Internal procedure; At permanent location (S) PW-1
4 Personal dosimeters Calibration — Dosimetric quantities
air kerma rate — 1 μGy/h to 14 mGy/h · CMC 2,4 % exposure rate — 0,1 μR/h to 1,6 mR/h · CMC 4,6 % absorbed dose rate in air — 1 μGy/h to 14 mGy/h · CMC 4,6 % ambient dose equivalent rate — 1,2 μSv/h to 17 mSv/h · CMC 4,6 % personal dose equivalent rate — 1,2 μSv/h to 17 mSv/h · CMC 4,6 % air kerma — 0,5 μGy to 10 Gy · CMC 2,4 % exposure — 0,5 μR to 1000 R · CMC 4,6 % absorbed dose — 0,5 μGy to 10 Gy · CMC 4,6 % ambient dose equivalent — 0,5 μSv to 10 Sv · CMC 4,6 % personal dose equivalent — 0,5 μSv to 10 Sv · CMC 4,6 %
Dosimetric quantities
Internal procedure; At permanent location (S) PW-1, PP-2