🇵🇱 Centralne Laboratorium Ochrony Radiologicznej PL
Metrology & calibration
Centralne Laboratorium Ochrony Radiologicznej is a calibration laboratory accredited by PCA under number AP 057 (Warszawa, Poland). Its accreditation scope covers 12 calibration items in the following areas: Metrology & calibration. Calibrated items include: Ionising radiation dosimeters, TLD dosimeters, Charcoal detectors, Dosimetric instruments for beta radiation measurement. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; Beta radiation measurement; At permanent locati…, Internal procedure; Gamma radiation measurement; At permanent locat….
At a glance
- Accreditation number: PCA AP 057
- Calibration items in scope: 12
- Types of calibrated items: 12
- Calibration principles used: 6
- City: Warszawa, Poland
- Valid until: 06-11-2027
- Accreditation number
- AP 057
- Accreditation body
- PCA
- Address
- ul. Konwaliowa 7, 03-194 Warszawa
- City
- Warszawa, Poland
- Division
- Calibration Laboratory for Dosimetric and Radon Instruments
- Valid until
- 06-11-2027
What this laboratory calibrates (12)
- Ionising radiation dosimeters — 4 calibration items
- TLD dosimeters — 4 calibration items
- Charcoal detectors — 1 calibration item
- Dosimetric instruments for beta radiation measurement — 1 calibration item
- Dosimetric instruments for gamma radiation measurement — 1 calibration item
- Dosimetric instruments for neutron radiation measurement — 1 calibration item
- Dosimetric instruments for X-radiation measurement — 1 calibration item
- Electrets — 1 calibration item
- Instruments for measuring potential alpha energy concentration — 1 calibration item
- Instruments for measuring radon activity concentration in air — 1 calibration item
- Meters and monitors for alpha/ beta surface contamination measurement — 1 calibration item
- Track detectors — 1 calibration item
Calibration principles (6)
- Internal procedure; At permanent location (S) — 7 calibration items
- Internal procedure; Beta radiation measurement; At permanent location (S) — 1 calibration item
- Internal procedure; Gamma radiation measurement; At permanent location (S) — 1 calibration item
- Internal procedure; Neutron radiation measurement — 1 calibration item
- Internal procedure; X-radiation for spectra N-40 to N-300; At permanent location (S) — 1 calibration item
- Internal procedure; X-radiation measurement for spectra N-40 to N-300; At permanent location (S) — 1 calibration item
Certificate information
- Issue date
- 11.09.2026
- Issue no.
- 22
- Certificate date
- 10.10.2019
- Accreditation cycle
- 16.10.2023 — 06.11.2027
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (12)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Dosimetric instruments for gamma radiation measurement | Calibration — Dosimetric quantities - air kerma rate; Cs-137, Co-60 — 1 µGy/h to 10 µGy/h · CMC 8,0 % - exposure rate; Cs-137, Co-60 — 0,1 mR/h to 1 mR/h · CMC 8,0 % - absorbed dose rate in air; Cs-137, Co-60 — 1 µGy/h to 10 µGy/h · CMC 8,0 % - dose equivalent rate; Cs-137, Co-60 — 1 µSv/h to 10 µSv/h · CMC 8,0 % - photon dose equivalent rate; Cs-137, Co-60 — 1 µSv/h to 10 µSv/h · CMC 8,0 % - ambient dose equivalent rate; Cs-137, Co-60 — 1 µSv/h to 10 µSv/h · CMC 8,0 % - personal dose equivalent rate; Cs-137, Co-60 — 1 µSv/h to 10 µSv/h · CMC 8,0 % - air kerma rate; Cs-137 — 0,01 mGy/h to 80 mGy/h · CMC 4,0 % - air kerma rate; Co-60 — 0,01 mGy/h to 4 mGy/h · CMC 5,0 % - air kerma rate; Am-241 — 15 µGy/h to 20 µGy/h · CMC 5,0 % - exposure rate; Cs-137 — 1 mR/h to 9000 mR/h · CMC 4,0 % - exposure rate; Co-60 — 1 mR/h to 500 mR/h · CMC 5,0 % - exposure rate; Am-241 — 2 mR/h to 2 mR/h · CMC 5,0 % - absorbed dose rate in air; Cs-137 — 0,01 mGy/h to 60 mGy/h · CMC 4,0 % - absorbed dose rate in air; Co-60 — 0,01 mGy/h to 5 mGy/h · CMC 5,0 % - absorbed dose rate in air; Am-241 — 15 µGy/h to 20 µGy/h · CMC 5,0 % - dose equivalent rate; Cs-137 — 0,01 mSv/h to 80 mSv/h · CMC 4,0 % - dose equivalent rate; Co-60 — 0,01 mSv/h to 5 mSv/h · CMC 5,0 % - dose equivalent rate; Am-241 — 15 µSv/h to 20 µSv/h · CMC 5,0 % - ambient dose equivalent rate; Cs-137 — 0,01 mSv/h to 95 mSv/h · CMC 4,0 % - ambient dose equivalent rate; Co-60 — 0,01 mSv/h to 5 mSv/h · CMC 5,0 % - ambient dose equivalent rate; Am-241 — 30 µSv/h to 40 µSv/h · CMC 5,0 % - personal dose equivalent rate; Cs-137 — 0,01 mSv/h to 95 mSv/h · CMC 4,0 % - personal dose equivalent rate; Co-60 — 0,01 mSv/h to 5 mSv/h · CMC 5,0 % - personal dose equivalent rate; Am-241 — 30 µSv/h to 40 µSv/h · CMC 5,0 % - air kerma; Cs-137 — 0,0003 mGy to 460 mGy · CMC 4,0 % - air kerma; Co-60 — 0,0002 mGy to 32 mGy · CMC 5,0 % - air kerma; Am-241 — 0,0004 mGy to 180 mGy · CMC 5,0 % - exposure; Cs-137 — 0,003 mR to 50000 mR · CMC 4,0 % - exposure; Co-60 — 0,002 mR to 4000 mR · CMC 5,0 % - exposure; Am-241 — 0,005 mR to 20 mR · CMC 5,0 % - absorbed dose in air; Cs-137 — 0,0003 mGy to 460 mGy · CMC 4,0 % - absorbed dose in air; Co-60 — 0,0002 mGy to 40 mGy · CMC 5,0 % - absorbed dose in air; Am-241 — 0,0004 mGy to 180 mGy · CMC 5,0 % - dose equivalent; Cs-137 — 0,0003 mSv to 460 mSv · CMC 4,0 % - dose equivalent; Co-60 — 0,0002 mSv to 40 mSv · CMC 5,0 % - dose equivalent; Am-241 — 0,0004 mSv to 180 mSv · CMC 5,0 % - ambient dose equivalent; Cs-137 — 0,0003 mSv to 550 mSv · CMC 4,0 % - ambient dose equivalent; Co-60 — 0,0002 mSv to 40 mSv · CMC 5,0 % - ambient dose equivalent; Am-241 — 0,7 µSv to 300 µSv · CMC 5,0 % - personal dose equivalent; Cs-137 — 0,0003 mSv to 550 mSv · CMC 4,0 % - personal dose equivalent; Co-60 — 0,0002 mSv to 40 mSv · CMC 5,0 % - personal dose equivalent; Am-241 — 0,8 µSv to 340 µSv · CMC 5,0 % Dosimetric quantities |
Internal procedure; At permanent location (S) | PW 1G | |
| 2 | TLD dosimeters Ionising radiation dosimeters |
Calibration — Dosimetric quantities - air kerma; Cs-137 — 0,0003 mGy to 460 mGy · CMC 4,0 % - air kerma; Co-60 — 0,0002 mGy to 32 mGy · CMC 5,0 % - air kerma; Am-241 — 0,0004 mGy to 180 mGy · CMC 5,0 % - exposure; Cs-137 — 0,003 mR to 50000 mR · CMC 4,0 % - exposure; Co-60 — 0,002 mR to 4000 mR · CMC 5,0 % - exposure; Am-241 — 0,005 mR to 20 mR · CMC 5,0 % - absorbed dose in air; Cs-137 — 0,0003 mGy to 460 mGy · CMC 4,0 % - absorbed dose in air; Co-60 — 0,0002 mGy to 40 mGy · CMC 5,0 % - absorbed dose in air; Am-241 — 0,0004 mGy to 180 mGy · CMC 5,0 % - dose equivalent; Cs-137 — 0,0003 mSv to 460 mSv · CMC 4,0 % - dose equivalent; Co-60 — 0,0002 mSv to 40 mSv · CMC 5,0 % - dose equivalent; Am-241 — 0,0004 mSv to 180 mSv · CMC 5,0 % - ambient dose equivalent; Cs-137 — 0,0003 mSv to 550 mSv · CMC 4,0 % - ambient dose equivalent; Co-60 — 0,0002 mSv to 40 mSv · CMC 5,0 % - ambient dose equivalent; Am-241 — 0,7 µSv to 300 µSv · CMC 5,0 % - personal dose equivalent; Cs-137 — 0,0003 mSv to 550 mSv · CMC 4,0 % - personal dose equivalent; Co-60 — 0,0002 mSv to 40 mSv · CMC 5,0 % - personal dose equivalent; Am-241 — 0,8 µSv to 340 µSv · CMC 5,0 % Dosimetric quantities |
Internal procedure; Gamma radiation measurement; At permanent location (S) | PW 1G | |
| 3 | Dosimetric instruments for X-radiation measurement | Calibration — Dosimetric quantities - air kerma rate — 0,003 mGy/h to 114 mGy/h · CMC 4,5 % - exposure rate — 0,3 mR/h to 11000 mR/h · CMC 4,5 % - absorbed dose rate in air — 0,003 mGy/h to 114 mGy/h · CMC 4,5 % - dose equivalent rate — 0,003 mSv/h to 114 mSv/h · CMC 4,5 % - ambient dose equivalent rate — 0,004 mSv/h to 180 mSv/h · CMC 4,5 % - personal dose equivalent rate — 0,004 mSv/h to 200 mSv/h · CMC 4,5 % - air kerma — 0,0001 mGy to 1000 mGy · CMC 4,5 % - exposure — 0,001 mR to 91000 mR · CMC 4,5 % - absorbed dose in air — 0,0001 mGy to 1000 mGy · CMC 4,5 % - dose equivalent — 0,0001 mSv to 1000 mSv · CMC 4,5 % - ambient dose equivalent — 0,0001 mSv to 1400 mSv · CMC 4,5 % - personal dose equivalent — 0,0001 mSv to 1600 mSv · CMC 4,5 % Dosimetric quantities |
Internal procedure; X-radiation for spectra N-40 to N-300; At permanent location (S) | PW 2X | |
| 4 | TLD dosimeters Ionising radiation dosimeters |
Calibration — Dosimetric quantities - air kerma — 0,0001 mGy to 1000 mGy · CMC 4,5 % - exposure — 0,001 mR to 91000 mR · CMC 4,5 % - absorbed dose in air — 0,0001 mGy to 1000 mGy · CMC 4,5 % - dose equivalent — 0,0001 mSv to 1000 mSv · CMC 4,5 % - ambient dose equivalent — 0,0001 mSv to 1400 mSv · CMC 4,5 % - personal dose equivalent — 0,0001 mSv to 1600 mSv · CMC 4,5 % Dosimetric quantities |
Internal procedure; X-radiation measurement for spectra N-40 to N-300; At permanent location (S) | PW 2X | |
| 5 | Dosimetric instruments for beta radiation measurement | Calibration — Dosimetric quantities - absorbed dose rate in air; Sr-90 — 14 mGy/h to 300 mGy/h · CMC 8,0 % - absorbed dose rate in air; Kr-85 — 60 mGy/h · CMC 8,0 % - directional dose equivalent rate; Sr-90 — 14 mSv/h to 300 mSv/h · CMC 8,0 % - directional dose equivalent rate; Kr-85 — 57 mSv/h · CMC 8,0 % - personal dose equivalent rate; Sr-90 — 14 mSv/h to 300 mSv/h · CMC 8,0 % - personal dose equivalent rate; Kr-85 — 57 mSv/h · CMC 8,0 % - absorbed dose in air; Sr-90 — 0,01 mGy to 5000 mGy · CMC 8,0 % - absorbed dose in air; Kr-85 — 0,01 mGy to 500 mGy · CMC 8,0 % - directional dose equivalent; Sr-90 — 0,01 mSv to 2500 mSv · CMC 8,0 % - directional dose equivalent; Kr-85 — 0,01 mSv to 250 mSv · CMC 8,0 % - personal dose equivalent; Sr-90 — 0,01 mSv to 2500 mSv · CMC 8,0 % - personal dose equivalent; Kr-85 — 0,01 mSv to 250 mSv · CMC 8,0 % Dosimetric quantities |
Internal procedure; At permanent location (S) | PW 6B | |
| 6 | TLD dosimeters Ionising radiation dosimeters |
Calibration — Dosimetric quantities - absorbed dose in air; Sr-90 — 0,01 mGy to 5000 mGy · CMC 8,0 % - absorbed dose in air; Kr-85 — 0,01 mGy to 500 mGy · CMC 8,0 % - directional dose equivalent; Sr-90 — 0,01 mSv to 2500 mSv · CMC 8,0 % - directional dose equivalent; Kr-85 — 0,01 mSv to 250 mSv · CMC 8,0 % - personal dose equivalent; Sr-90 — 0,01 mSv to 2500 mSv · CMC 8,0 % - personal dose equivalent; Kr-85 — 0,01 mSv to 250 mSv · CMC 8,0 % Dosimetric quantities |
Internal procedure; Beta radiation measurement; At permanent location (S) | PW 6B | |
| 7 | Dosimetric instruments for neutron radiation measurement | Calibration — Dosimetric quantities - ambient dose equivalent rate; ²⁴¹Am/Be — 10 µSv/h to 200 µSv/h · CMC 17,0 % - personal dose equivalent rate; ²⁴¹Am/Be — 10 µSv/h to 200 µSv/h · CMC 17,0 % - ambient dose equivalent; ²⁴¹Am/Be — 0,005 mSv to 20 mSv · CMC 17,0 % - personal dose equivalent; ²⁴¹Am/Be — 0,005 mSv to 20 mSv · CMC 17,0 % Dosimetric quantities |
Internal procedure; At permanent location (S) | PW 4N | |
| 8 | TLD dosimeters Ionising radiation dosimeters |
Calibration — Dosimetric quantities - ambient dose equivalent; ²⁴¹Am/Be — 0,005 mSv to 20 mSv · CMC 17,0 % - personal dose equivalent; ²⁴¹Am/Be — 0,005 mSv to 20 mSv · CMC 17,0 % Dosimetric quantities |
Internal procedure; Neutron radiation measurement | PW 4N | |
| 9 | Meters and monitors for alpha/ beta surface contamination measurement | Calibration — Surface emission of radiation Am-241 — 3,59 s⁻¹cm⁻² · CMC 8,0 % C-14 — 2,38 s⁻¹cm⁻² · CMC 8,0 % Cl-36 — 4,05 s⁻¹cm⁻² · CMC 7,0 % Sr-90 — 6,74 s⁻¹cm⁻² · CMC 7,0 % Surface emission of radiation |
Internal procedure; At permanent location (S) | PW 3S | |
| 10 | Instruments for measuring radon activity concentration in air | Calibration — Radon measurements Rn-222 — 50 Bq/m³ to 1 000 Bq/m³ · CMC 6,5 % Rn-222 — 1 kBq/m³ to 50 kBq/m³ · CMC 6,1 % Radon measurements |
Internal procedure; At permanent location (S) | PW 5R | |
| 11 | Instruments for measuring potential alpha energy concentration | Calibration — Radon measurements Rn-222 — 1 µJ/m³ to 250 µJ/m³ · CMC 6,0 % Radon measurements |
Internal procedure; At permanent location (S) | PW 5R | |
| 12 | Track detectors Charcoal detectors Electrets |
Calibration — Radon measurements Rn-222 — 6 kBq·h/m³ to 6 000 kBq·h/m³ · CMC 6,1 % Radon measurements |
Internal procedure; At permanent location (S) | PW 5R | |
Reference standards (6)
PW 1G
PW 2X
PW 3S
PW 4N
PW 5R
PW 6B