Metrology & calibration
KASPO LAB Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 043 (Gdańsk, Poland). Its accreditation scope covers 15 calibration items in the following areas: Metrology & calibration. Calibrated items include: Load weights, Mass standards 25 kg, Automatic catchweighing instruments, Automatic conveyor weighing instruments. Most frequently used calibration principles: Internal procedure; Outside of permanent location (P), Internal procedure; At permanent location (S), Internal procedure; At permanent location (S) and outside of it (P).
At a glance
- Accreditation number: PCA AP 043
- Calibration items in scope: 15
- Types of calibrated items: 14
- Calibration principles used: 3
- City: Gdańsk, Poland
- Valid until: 09-12-2026
- Accreditation number
- AP 043
- Accreditation body
- PCA
- Address
- ul. Prometeusza 3, 80-299 Gdańsk
- City
- Gdańsk, Poland
- Division
- KASPO LAB Calibration Laboratory for Weighing Instruments and Mass Standards
- Valid until
- 09-12-2026
What this laboratory calibrates (14)
- Load weights — 2 calibration items
- Mass standards 25 kg — 2 calibration items
- Automatic catchweighing instruments — 1 calibration item
- Automatic conveyor weighing instruments — 1 calibration item
- Automatic gravimetric filling instruments — 1 calibration item
- Automatic portioning weighing instruments — 1 calibration item
- Automatic rail weighbridges — 1 calibration item
- Electronic non-automatic weighing instruments — 1 calibration item
- Mass standards and weights of accuracy classes E2, F1, F2, M1, M2, M3**, load weights — 1 calibration item
- Mass standards and weights of accuracy classes F1, F2, M1, M2, M3** — 1 calibration item
- Mass standards and weights of accuracy classes F2, M1, M2, M3** — 1 calibration item
- Mass standards and weights of accuracy classes M1, M2, M3 — 1 calibration item
- Mass standards and weights of accuracy classes M1, M2, M3**, load weights — 1 calibration item
- Mechanical non-automatic weighing instruments — 1 calibration item
Calibration principles (3)
- Internal procedure; Outside of permanent location (P) — 8 calibration items
- Internal procedure; At permanent location (S) — 6 calibration items
- Internal procedure; At permanent location (S) and outside of it (P) — 1 calibration item
Certificate information
- Issue date
- 11.07.2025
- Issue no.
- 25
- Certificate date
- 28.07.2020
- Accreditation cycle
- 15.11.2022 — 09.12.2026
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (15)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Electronic non-automatic weighing instruments Mechanical non-automatic weighing instruments |
Calibration — Mass (weighing instruments) up to 300 g · CMC 7·10⁻⁵ % powyżej 300 g do 20 kg · CMC 1·10⁻⁴ % powyżej 20 kg do 7 000 kg · CMC 6·10⁻⁴ % powyżej 7 000 kg do 150 000 kg · CMC 5·10⁻³ % Mass (weighing instruments) |
Internal procedure; At permanent location (S) and outside of it (P) | I-01, I-10 based on EURAMET/cg-18/v.4 | |
| 2 | Automatic conveyor weighing instruments | Calibration — Mass (weighing instruments) material portion* — up to 150 000 kg · CMC 1,5·10⁻¹ % Mass (weighing instruments) |
Internal procedure; Outside of permanent location (P) | I-11 based on OIML R 50-1:2014 | |
| 3 | Automatic gravimetric filling instruments | Calibration — Mass (weighing instruments) material portion* — up to 150 000 kg · CMC 1,1·10⁻¹ % Mass (weighing instruments) |
Internal procedure; Outside of permanent location (P) | I-11 based on OIML R 107-1:2007 | |
| 4 | Automatic portioning weighing instruments | Calibration — Mass (weighing instruments) material portion* — up to 150 000 kg · CMC 1,7·10⁻² % Mass (weighing instruments) |
Internal procedure; Outside of permanent location (P) | I-11 based on OIML R 61-1,2:2017 | |
| 5 | Automatic catchweighing instruments | Calibration — Mass (weighing instruments) load mass — up to 100 kg · CMC 1,3·10⁻² % Mass (weighing instruments) |
Internal procedure; Outside of permanent location (P) | I-11 based on OIML R 51-1:2006 | |
| 6 | Automatic rail weighbridges | Calibration — Mass (weighing instruments) up to 150 000 kg · CMC 4·10⁻² % Mass (weighing instruments) |
Internal procedure; Outside of permanent location (P) | I-10 based on OIML R 106-1:2011 | |
| 7 | Mass standards and weights of accuracy classes E2, F1, F2, M1, M2, M3**, load weights | Calibration — Mass (weights and mass standards) 1 mg · CMC 0,002 mg 2 mg · CMC 0,002 mg 5 mg · CMC 0,002 mg 10 mg · CMC 0,002 mg 20 mg · CMC 0,002 mg 50 mg · CMC 0,004 mg 100 mg · CMC 0,004 mg 200 mg · CMC 0,005 mg 500 mg · CMC 0,005 mg 1 g · CMC 0,007 mg 2 g · CMC 0,008 mg 5 g · CMC 0,010 mg 10 g · CMC 0,013 mg 20 g · CMC 0,016 mg 50 g · CMC 0,020 mg 100 g · CMC 0,032 mg 200 g · CMC 0,07 mg 500 g · CMC 0,16 mg 1 kg · CMC 0,31 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | I-02 based on OIML R 111-1:2004 Annex C | |
| 8 | Mass standards and weights of accuracy classes F1, F2, M1, M2, M3** | Calibration — Mass (weights and mass standards) 2 kg · CMC 1,7 mg 5 kg · CMC 4,1 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | I-02 based on OIML R 111-1:2004 Annex C | |
| 9 | Mass standards and weights of accuracy classes F2, M1, M2, M3** | Calibration — Mass (weights and mass standards) 10 kg · CMC 25 mg 20 kg · CMC 47 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | I-02 based on OIML R 111-1:2004 Annex C | |
| 10 | Mass standards and weights of accuracy classes M1, M2, M3 | Calibration — Mass (weights and mass standards) 50 kg · CMC 190 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | I-02 based on OIML R 111-1:2004 Annex C | |
| 11 | Mass standards and weights of accuracy classes M1, M2, M3**, load weights | Calibration — Mass (weights and mass standards) 10 kg · CMC 51 mg 20 kg · CMC 100 mg 50 kg · CMC 250 mg 500 kg · CMC 8 g 1000 kg · CMC 16 g 2000 kg · CMC 33 g Mass (weights and mass standards) |
Internal procedure; Outside of permanent location (P) | I-02 based on OIML R 111-1:2004 Annex C | |
| 12 | Mass standards 25 kg | Calibration — Mass (weights and mass standards) 25 kg · CMC 70 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | I-02 based on OIML R 111-1:2004 Annex C | |
| 13 | Mass standards 25 kg | Calibration — Mass (weights and mass standards) 25 kg · CMC 130 mg Mass (weights and mass standards) |
Internal procedure; Outside of permanent location (P) | I-02 based on OIML R 111-1:2004 Annex C | |
| 14 | Load weights | Calibration — Mass (weights and mass standards) 1 mg to 5 mg · CMC 0,003 mg 5 mg to 10 mg · CMC 0,003 mg 10 mg to 20 mg · CMC 0,004 mg 20 mg to 50 mg · CMC 0,007 mg 50 mg to 100 mg · CMC 0,007 mg 100 mg to 200 mg · CMC 0,009 mg 200 mg to 500 mg · CMC 0,011 mg 500 mg to 1 g · CMC 0,014 mg 1 g to 2 g · CMC 0,017 mg 2 g to 5 g · CMC 0,024 mg 5 g to 10 g · CMC 0,029 mg 10 g to 20 g · CMC 0,035 mg 20 g to 50 g · CMC 0,05 mg 50 g to 100 g · CMC 0,06 mg 100 g to 200 g · CMC 0,09 mg 200 g to 500 g · CMC 0,17 mg 500 g to 1 kg · CMC 0,33 mg 1 kg to 2 kg · CMC 1,7 mg 2 kg to 5 kg · CMC 4,1 mg 5 kg to 10 kg · CMC 25 mg 10 kg to 20 kg · CMC 47 mg 20 kg to 25 kg · CMC 70 mg 25 kg to 64 kg · CMC 190 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | I-02 based on OIML R 111-1:2004 Annex C | |
| 15 | Load weights | Calibration — Mass (weights and mass standards) 5 kg to 10 kg · CMC 51 mg 10 kg to 20 kg · CMC 100 mg 20 kg to 25 kg · CMC 130 mg 25 kg to 64 kg · CMC 250 mg Mass (weights and mass standards) |
Internal procedure; Outside of permanent location (P) | I-02 based on OIML R 111-1:2004 Annex C | |
Reference standards (11)
EURAMET/cg-18/v.4
I-01
I-02
I-10
I-11
OIML R 106-1:2011
OIML R 107-1:2007
OIML R 111-1:2004 Załącznik C
OIML R 50-1:2014
OIML R 51-1:2006
OIML R 61-1,2:2017