🇵🇱 Centralna Stacja Ratownictwa Górniczego S.A. PL

PCA AP 028 • Bytom, Poland • 8 calibration items

Metrology & calibration

Centralna Stacja Ratownictwa Górniczego S.A. is a calibration laboratory accredited by PCA under number AP 028 (Bytom, Poland). Its accreditation scope covers 8 calibration items in the following areas: Metrology & calibration. Calibrated items include: Carbon monoxide in a gas mixture, Carbon dioxide in a gas mixture, Ethane in a gas mixture, Ethene in a gas mixture. Most frequently used calibration principles: Internal procedure; Chromatographic method; At permanent location (S), Internal procedure; Conductometric method; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 028
  • Calibration items in scope: 8
  • Types of calibrated items: 7
  • Calibration principles used: 2
  • City: Bytom, Poland
  • Valid until: 20-12-2029
Accreditation number
AP 028
Accreditation body
PCA
Address
ul. Chorzowska 25, 41-902 Bytom
City
Bytom, Poland
Division
Laboratorium Chemiczne
Valid until
20-12-2029

What this laboratory calibrates (7)

Calibration principles (2)

Certificate information

Issue date
24.11.2025
Issue no.
20
Certificate date
27.11.2020
Accreditation cycle
24.11.2025 — 20.12.2029
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (8)

The uncertainty covered by the CMC does not include the uncertainty components related to the stability and homogeneity of the reference material. The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. The measurement uncertainty value for CMC expressed as a percentage is the relative measurement uncertainty and refers to the percentage share in the measured value.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Oxygen in a gas mixture Measurement — Reference materials
10 · 10⁻² mol/mol to 19 · 10⁻² mol/mol · CMC 1,8 %
Reference materials
Internal procedure; Chromatographic method; At permanent location (S) PP-GC/AP 028
2 Carbon dioxide in a gas mixture Measurement — Reference materials
2 · 10⁻² mol/mol to 6 · 10⁻² mol/mol · CMC 2,4 %
Reference materials
Internal procedure; Chromatographic method; At permanent location (S) PP-GC/AP 028
3 Carbon monoxide in a gas mixture Measurement — Reference materials
10 · 10⁻⁶ mol/mol to 100 · 10⁻⁶ mol/mol · CMC 6 · 10⁻⁶ mol/mol 101 · 10⁻⁶ mol/mol to 300 · 10⁻⁶ mol/mol · CMC 13 · 10⁻⁶ mol/mol 301 · 10⁻⁶ mol/mol to 500 · 10⁻⁶ mol/mol · CMC 21 · 10⁻⁶ mol/mol 501 · 10⁻⁶ mol/mol to 1000 · 10⁻⁶ mol/mol · CMC 41 · 10⁻⁶ mol/mol
Reference materials
Internal procedure; Conductometric method; At permanent location (S) PP-CO/AP 028
4 Carbon monoxide in a gas mixture Measurement — Reference materials
1 · 10⁻² mol/mol to 2 · 10⁻² mol/mol · CMC 2,2 %
Reference materials
Internal procedure; Chromatographic method; At permanent location (S) PP-GC/AP 028
5 Methane in a gas mixture Measurement — Reference materials
0,5 · 10⁻² mol/mol to 6,0 · 10⁻² mol/mol · CMC 1,9 % 20 · 10⁻² mol/mol to 40 · 10⁻² mol/mol · CMC 1,9 %
Reference materials
Internal procedure; Chromatographic method; At permanent location (S) PP-GC/AP 028
6 Hydrogen in a gas mixture Measurement — Reference materials
1 · 10⁻² mol/mol to 2 · 10⁻² mol/mol · CMC 2,8 %
Reference materials
Internal procedure; Chromatographic method; At permanent location (S) PP-GC/AP 028
7 Ethene in a gas mixture Measurement — Reference materials
0,2 · 10⁻² mol/mol to 0,6 · 10⁻² mol/mol · CMC 2,2 %
Reference materials
Internal procedure; Chromatographic method; At permanent location (S) PP-GC/AP 028
8 Ethane in a gas mixture Measurement — Reference materials
0,2 · 10⁻² mol/mol to 0,6 · 10⁻² mol/mol · CMC 2,3 %
Reference materials
Internal procedure; Chromatographic method; At permanent location (S) PP-GC/AP 028

Reference standards (2)

PP-CO/AP 028
PP-GC/AP 028