🇵🇱 Auto - Stoma Patrycjusz Stoma PL
Metrology & calibration
Auto - Stoma Patrycjusz Stoma is a calibration laboratory accredited by PCA under number AP 011 (Lublin, Poland). Its accreditation scope covers 4 calibration items in the following areas: Metrology & calibration. Calibrated items include: Analog dial indicators with scale interval of 0,01 mm, Automotive exhaust gas analysers, Calipers, Digital indicators with resolution of 0,01 mm. Most frequently used calibration principles: Internal procedure; Direct method by comparison with gauge blocks;…, Internal procedure; Direct method by comparison with a micrometer h…, Internal procedure; Direct method using certified reference materia….
At a glance
- Accreditation number: PCA AP 011
- Calibration items in scope: 4
- Types of calibrated items: 5
- Calibration principles used: 3
- City: Lublin, Poland
- Valid until: 17-12-2026
- Accreditation number
- AP 011
- Accreditation body
- PCA
- Address
- ul. Jagiellońska 2D, 20-806 Lublin
- City
- Lublin, Poland
- Division
- Laboratorium Pomiarowe AUTO-STOMA
- Valid until
- 17-12-2026
What this laboratory calibrates (5)
- Analog dial indicators with scale interval of 0,01 mm — 1 calibration item
- Automotive exhaust gas analysers — 1 calibration item
- Calipers — 1 calibration item
- Digital indicators with resolution of 0,01 mm — 1 calibration item
- External micrometers — 1 calibration item
Calibration principles (3)
- Internal procedure; Direct method by comparison with gauge blocks; At permanent location (S) — 2 calibration items
- Internal procedure; Direct method by comparison with a micrometer head; At permanent location (S) — 1 calibration item
- Internal procedure; Direct method using certified reference materials (CRM); At permanent location (S) — 1 calibration item
Certificate information
- Issue date
- 24.10.2025
- Issue no.
- 20
- Certificate date
- 27.11.2020
- Accreditation cycle
- 12.12.2022 — 17.12.2026
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (4)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Automotive exhaust gas analysers | Calibration — Mole fraction (gas analysis) CO — 4 mmol/mol to 6 mmol/mol · CMC 5 % CO — 29 mmol/mol to 43 mmol/mol · CMC 3 % CO2 — 48 mmol/mol to 71 mmol/mol · CMC 3 % CO2 — 111 mmol/mol to 166 mmol/mol · CMC 3 % C3H8 — 160 µmol/mol to 240 µmol/mol · CMC 5 % C3H8 — 1600 µmol/mol to 2400 µmol/mol · CMC 3 % Mole fraction (gas analysis) |
Internal procedure; Direct method using certified reference materials (CRM); At permanent location (S) | IJ-02 | |
| 2 | Calipers | Calibration — Length 0 mm to 250 mm · CMC 15 µm Length |
Internal procedure; Direct method by comparison with gauge blocks; At permanent location (S) | IJ-03 | |
| 3 | External micrometers | Calibration — Length 0 mm to 25 mm · CMC 5 µm 25 mm to 50 mm · CMC 6 µm 50 mm to 75 mm · CMC 7 µm 75 mm to 100 mm · CMC 8 µm Length |
Internal procedure; Direct method by comparison with gauge blocks; At permanent location (S) | IJ-04 | |
| 4 | Analog dial indicators with scale interval of 0,01 mm Digital indicators with resolution of 0,01 mm |
Calibration — Length analog dial indicators — 0 mm to 25 mm · CMC 7 µm digital indicators — 0 mm to 50 mm · CMC 5 µm Length |
Internal procedure; Direct method by comparison with a micrometer head; At permanent location (S) | IJ-06 | |
Reference standards (4)
IJ-02
IJ-03
IJ-04
IJ-06