🇵🇱 Główny Instytut Górnictwa - Państwowy Instytut Badawczy PL

PCA AP 006 • Katowice, Poland • 15 calibration items

Metrology & calibration

Główny Instytut Górnictwa - Państwowy Instytut Badawczy is a calibration laboratory accredited by PCA under number AP 006 (Katowice, Poland). Its accreditation scope covers 15 calibration items in the following areas: Metrology & calibration. Calibrated items include: Sound level meters, Measurement microphones, Sound calibrators, Aspirators. Most frequently used calibration principles: At permanent location (S), Class LS sound calibrator method; At permanent location (S), Comparison method; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 006
  • Calibration items in scope: 15
  • Types of calibrated items: 11
  • Calibration principles used: 4
  • City: Katowice, Poland
  • Valid until: 30-12-2029
Accreditation number
AP 006
Accreditation body
PCA
Address
Plac Gwarków 1, 40-166 Katowice
City
Katowice, Poland
Division
GIG - PIB Testing and Calibration Laboratories
Valid until
30-12-2029

What this laboratory calibrates (11)

Calibration principles (4)

Certificate information

Issue date
04.12.2025
Issue no.
20
Certificate date
25.08.2023
Accreditation cycle
04.12.2025 — 30.12.2029
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (15)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Sound level meters Calibration — Sound pressure (airborne sound)
- response of the sound level meter to the signal from a sound calibrator — relative to 20 µPa; from 90 dB to 130 dB · CMC 0,2 dB - response of the sound level meter to electrical test signals — relative to 20 µPa; frequency range: from 20 Hz to 20 kHz; from 0 dB to 140 dB · CMC 0,2 dB
Sound pressure (airborne sound)
At permanent location (S) PN-EN 60651:2002 (U) PN-EN 60804:2002 (U) PN-EN 61672-3:2007 PN-EN 61672-3:2014-03
2 Sound level meters Calibration — Sound pressure (airborne sound)
- free-field frequency response of the sound level meter — frequency range: from 20 Hz to 25 Hz, · CMC 0,4 dB - free-field frequency response of the sound level meter — frequency range: from 31,5 Hz to 1 kHz · CMC 0,3 dB - free-field frequency response of the sound level meter — frequency range: from 2 kHz to 4 kHz · CMC 0,3 dB - free-field frequency response of the sound level meter — frequency range: from 8 kHz to 16 kHz · CMC 0,4 dB
Sound pressure (airborne sound)
At permanent location (S) PN-EN 60651:2002 (U) PN-EN 60804:2002 (U)
3 Sound level meters Calibration — Sound pressure (airborne sound)
- free-field frequency response of the sound level meter — frequencies: 125 Hz · CMC 0,3 dB - free-field frequency response of the sound level meter — frequencies: 1 kHz · CMC 0,3 dB - free-field frequency response of the sound level meter — frequencies: 4 kHz · CMC 0,4 dB - free-field frequency response of the sound level meter — frequencies: 8 kHz · CMC 0,4 dB
Sound pressure (airborne sound)
At permanent location (S) PN-EN 61672-3:2007 PN-EN 61672-3:2014-03
4 Sound calibrators Calibration — Sound pressure (airborne sound)
- sound pressure level — relative to 20 µPa; nominal frequencies: 250 Hz, 1000 Hz; from 90 dB to 130 dB · CMC 0,07 dB
Sound pressure (airborne sound)
Reference microphone method; At permanent location (S) PN-EN 60942:2005 Reference microphone method PN-EN 60942:2018 Reference microphone method
5 Sound calibrators Calibration — Sound pressure (airborne sound)
- sound pressure level — relative to 20 µPa; nominal frequencies: 250 Hz, 1000 Hz; from 90 dB to 130 dB · CMC 0,1 dB
Sound pressure (airborne sound)
Comparison method; At permanent location (S) PN-EN 60942:2005 Comparison method PN-EN 60942:2018 Comparison method
6 Measurement microphones Calibration — Sound pressure (airborne sound)
- pressure sensitivity level of the microphone; WS1 — relative to 1V/Pa; frequency 250 Hz; from -40 dB to -25 dB · CMC 0,08 dB - pressure sensitivity level of the microphone; WS2 — relative to 1V/Pa; frequency 250 Hz; from -40 dB to -25 dB · CMC 0,09 dB
Sound pressure (airborne sound)
Class LS sound calibrator method; At permanent location (S) BR-1/ZLGIG/ PP-07
7 Measurement microphones Calibration — Sound pressure (airborne sound)
- frequency response of the electrostatically actuated microphone; Class WS1 microphones — frequency range: 20 Hz · CMC 0,3 dB - frequency response of the electrostatically actuated microphone; Class WS1 microphones — frequency range: 25 Hz · CMC 0,3 dB - frequency response of the electrostatically actuated microphone; Class WS1 microphones — frequency range: from 31,5 Hz to 1 kHz · CMC 0,3 dB - frequency response of the electrostatically actuated microphone; Class WS1 microphones — frequency range: from 1,25 kHz to 20 kHz · CMC 0,4 dB - frequency response of the electrostatically actuated microphone; Class WS2 microphones — frequency range: 20 Hz · CMC 0,3 dB - frequency response of the electrostatically actuated microphone; Class WS2 microphones — frequency range: 25 Hz · CMC 0,3 dB - frequency response of the electrostatically actuated microphone; Class WS2 microphones — frequency range: from 31,5 Hz to 1 kHz · CMC 0,3 dB - frequency response of the electrostatically actuated microphone; Class WS2 microphones — frequency range: from 1,25 kHz to 20 kHz · CMC 0,4 dB
Sound pressure (airborne sound)
At permanent location (S) PN-EN 61094-6:2005
8 Octave-band and one-third-octave-band filters Calibration — Sound pressure (airborne sound)
- relative attenuation of the filters — from 0 dB to 100 dB; filter centre frequencies: from 20 Hz od 20 kHz; ≤ 50 dB · CMC 0,3 dB - relative attenuation of the filters — from 0 dB to 100 dB; filter centre frequencies: from 20 Hz od 20 kHz; > 50 dB · CMC 0,2 dB - response of the sound level meter with band-pass filters to electrical test signals — relative to 20 µPa; filter centre frequencies: from 20 Hz to 20 kHz; from 0 dB to 140 dB · CMC 0,2 dB
Sound pressure (airborne sound)
At permanent location (S) PN-EN 61260:2000
9 Vibration transducers Calibration — Acceleration of mechanical vibration Sensitivity of vibration transducers
- reference sensitivity — for frequency: 16 Hz · CMC 1,2 % - reference sensitivity — for frequency: 80 Hz · CMC 1,1 % - frequency response — in the frequency range: 0,5 Hz ≤ f < 10 Hz · CMC 1,1 % - frequency response — in the frequency range: 10 Hz ≤ f ≤ 100 Hz · CMC 1,2 % - frequency response — in the frequency range: 100 Hz < f < 1 kHz · CMC 1,1 % - frequency response — in the frequency range: 1 kHz ≤ f ≤ 4 kHz · CMC 1,4 % - frequency response — in the frequency range: 4 kHz < f < 10 kHz · CMC 1,9 % - frequency response — in the frequency range: 10 kHz ≤ f ≤ 15 kHz · CMC 2,2 %
Acceleration of mechanical vibration Sensitivity of vibration transducers
At permanent location (S) ISO 16063-21:2003
10 Human-response vibration meters Calibration — Acceleration of mechanical vibration Sensitivity of vibration transducers
- response of the meter to the reference signal — for 15,915 Hz; 1 m·s⁻² · CMC 1,8 % - response of the meter to the reference signal — for 79,58 Hz; 10 m·s⁻² · CMC 1,9 % - frequency responses of the meter — for filters: Wd, Wk; in the frequency range: 2 Hz to 63 Hz · CMC 2,1 % - frequency responses of the meter — for filter Wh; in the frequency range: 10 Hz to 800 Hz · CMC 1,8 % - determination of the linearity errors of the meter — for 15,915 Hz; 0,1 m·s⁻² to 10 m·s⁻² · CMC 1,8 % - determination of the linearity errors of the meter — for 79,58 Hz; 5 m·s⁻² to 100 m·s⁻² · CMC 1,8 %
Acceleration of mechanical vibration Sensitivity of vibration transducers
At permanent location (S) PN-EN ISO 8041-1:2017
11 Machine vibration meters Calibration — Acceleration of mechanical vibration Sensitivity of vibration transducers
- response of the meter to the reference signal for a mechanical signal — 10 m·s⁻² for 79,4 Hz · CMC 1,9 % - frequency responses of the meter for a mechanical signal — in the frequency range: 0,5 Hz to 2000 Hz · CMC 2,2 %
Acceleration of mechanical vibration Sensitivity of vibration transducers
At permanent location (S) ISO 16063-21:2003
12 Vibration calibrators Calibration — Acceleration of mechanical vibration Sensitivity of vibration transducers
- vibration acceleration — in the frequency range: 15 Hz to 40 Hz · CMC 0,9 % - vibration acceleration — in the frequency range: 80 Hz to 2 kHz · CMC 1,0 %
Acceleration of mechanical vibration Sensitivity of vibration transducers
At permanent location (S) ISO 16063-21:2003
13 CIP-10 type dust samplers Calibration — Volume flow rate (flow - gases)
9,8 dm³/min to 10,2 dm³/min · CMC 0,13 dm³/min
Volume flow rate (flow - gases)
At permanent location (S) KD-2.2/ZLGIG/PW-2203
14 Barbara 3A type dust samplers Calibration — Volume flow rate (flow - gases)
4,5 dm³/min to 5,5 dm³/min · CMC 0,13 dm³/min
Volume flow rate (flow - gases)
At permanent location (S) KD-2.2/ZLGIG/PW-2202
15 Aspirators Calibration — Volume flow rate (flow - gases)
1,7 dm³/min to 2,4 dm³/min · CMC 0,13 dm³/min
Volume flow rate (flow - gases)
At permanent location (S) KD-2.2/ZLGIG/PW-2203-1

Reference standards (14)

BR-1/ZLGIG/ PP-07
ISO 16063-21:2003
KD-2.2/ZLGIG/PW-2202
KD-2.2/ZLGIG/PW-2203
KD-2.2/ZLGIG/PW-2203-1
PN-EN 60651:2002 (U)
PN-EN 60804:2002 (U)
PN-EN 60942:2005
PN-EN 60942:2018
PN-EN 61094-6:2005
PN-EN 61260:2000
PN-EN 61672-3:2007
PN-EN 61672-3:2014-03
PN-EN ISO 8041-1:2017

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20006