🇵🇱 Radiotechnika Serwis Sp. z o.o. PL
Metrology & calibration
Radiotechnika Serwis Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 002 (Wrocław, Poland). Its accreditation scope covers 3 calibration items in the following areas: Metrology & calibration. Calibrated items include: Automotive exhaust gas analysers, Flue gas analysers, Gas composition analyzers, Gas concentration meters. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; Calibration using C3H8 in syntehetic air; At pe….
At a glance
- Accreditation number: PCA AP 002
- Calibration items in scope: 3
- Types of calibrated items: 6
- Calibration principles used: 2
- City: Wrocław, Poland
- Valid until: 26-09-2029
- Accreditation number
- AP 002
- Accreditation body
- PCA
- Address
- ul. Sienkiewicza 4, 50-335 Wrocław
- City
- Wrocław, Poland
- Division
- Laboratorium Pomiarowe Analizatorów Spalin Samochodowych
- Valid until
- 26-09-2029
What this laboratory calibrates (6)
- Automotive exhaust gas analysers — 1 calibration item
- Flue gas analysers — 1 calibration item
- Gas composition analyzers — 1 calibration item
- Gas concentration meters — 1 calibration item
- Multi-gas analyzers — 1 calibration item
- Total organic carbon analyzers with FID detector — 1 calibration item
Calibration principles (2)
- Internal procedure; At permanent location (S) — 2 calibration items
- Internal procedure; Calibration using C3H8 in syntehetic air; At permanent location (S) — 1 calibration item
Certificate information
- Issue date
- 30.07.2026
- Issue no.
- 24
- Certificate date
- 24.05.2019
- Accreditation cycle
- 01.09.2025 — 26.09.2029
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (3)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Total organic carbon analyzers with FID detector | Calibration — Mole fraction (gas analysis) 0 μmol/mol to 1 μmol/mol · CMC 0,03 μmol/mol 1 μmol/mol to 817 μmol/mol · CMC 3 % Mole fraction (gas analysis) |
Internal procedure; Calibration using C3H8 in syntehetic air; At permanent location (S) | PW-03 | |
| 2 | Automotive exhaust gas analysers | Calibration — Mole fraction (gas analysis) CO — 4 mmol/mol to 6 mmol/mol · CMC 2 % CO — 28 mmol/mol to 42 mmol/mol · CMC 2 % CO2 — 48 mmol/mol to 72 mmol/mol · CMC 2 % CO2 — 112 mmol/mol to 168 mmol/mol · CMC 2 % C3H8 — 160 μmol/mol to 240 μmol/mol · CMC 4 % C3H8 — 1600 μmol/mol to 2400 μmol/mol · CMC 2 % Mole fraction (gas analysis) |
Internal procedure; At permanent location (S) | PW-01 | |
| 3 | Gas composition analyzers Flue gas analysers Multi-gas analyzers Gas concentration meters |
Calibration — Mole fraction (gas analysis) CO — 0 μmol/mol to 1 μmol/mol · CMC 0,03 μmol/mol CO — 1 μmol/mol to 5000 μmol/mol · CMC 3 % NO — 0 μmol/mol to 1 μmol/mol · CMC 0,03 μmol/mol NO — 1 μmol/mol to 2000 μmol/mol · CMC 3 % CH4 — 0 mmol/mol to 0,125 mmol/mol · CMC 0,005 mmol/mol CH4 — 0,125 mmol/mol to 25 mmol/mol · CMC 4 % SO2 — 0 μmol/mol to 1 μmol/mol · CMC 0,03 μmol/mol SO2 — 1 μmol/mol to 3000 μmol/mol · CMC 3 % NO2 — 0 μmol/mol to 0,50 μmol/mol · CMC 0,015 μmol/mol NO2 — 0,50 μmol/mol to 200 μmol/mol · CMC 3 % CO2 — 0 mmol/mol to 0,1 mmol/mol · CMC 0,003 mmol/mol CO2 — 0,1 mmol/mol to 300 mmol/mol · CMC 3 % O2 — 0 mmol/mol to 2,2 mmol/mol · CMC 0,066 mmol/mol O2 — 2,2 mmol/mol to 300 mmol/mol · CMC 3 % Mole fraction (gas analysis) |
Internal procedure; At permanent location (S) | PW-02 | |
Reference standards (3)
PW-01
PW-02
PW-03