Zakłady Badań i Atestacji "Zetom" im. Profesora Fryderyka Stauba w Katowicach Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 001 (Katowice, Poland). Its accreditation scope covers 58 calibration items in the following areas: Metrology & calibration. Calibrated items include: Multimeters, Power supplies, Analogue ammeters, Analogue voltmeters. Most frequently used calibration principles: Internal procedure; At permanent location (S) and outside of it (P), Internal procedure; At permanent location (S), At permanent location (S) and outside of it (P).

At a glance

  • Accreditation number: PCA AP 001
  • Calibration items in scope: 58
  • Types of calibrated items: 54
  • Calibration principles used: 7
  • City: Katowice, Poland
  • Valid until: 30-09-2029
Accreditation number
AP 001
Accreditation body
PCA
Address
ul. Ks. Bpa. H. Bednorza 17, 40-384 Katowice
City
Katowice, Poland
Division
Testing and Calibration Laboratory - Calibration Team
Valid until
30-09-2029

What this laboratory calibrates (54)

Calibration principles (7)

Certificate information

Issue date
02.09.2025
Issue no.
28
Certificate date
28.06.2019
Accreditation cycle
02.09.2025 — 30.09.2029
Approved by
Tadeusz Matras

Accreditation scope — calibration items (58)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. A value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand. In other cases the CMC uncertainty is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Analogue dial gauges Calibration — Length
– scale interval 0,01 mm — 0 mm to 15 mm · CMC 3,7 µm – scale interval 0,01 mm — 0 mm to 50 mm · CMC 3,8 µm
Length
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-0427
2 Analogue and digital dial gauges Calibration — Length
– scale interval 0,001 mm — 0 mm to 50 mm · CMC 2,6 µm
Length
Internal procedure; At permanent location (S) Internal procedure Qliw-0462
3 Digital dial gauges Calibration — Length
– resolution 0,01 mm — 0 mm to 15 mm · CMC 6,4 µm – resolution 0,01 mm — 0 mm to 50 mm · CMC 6,7 µm
Length
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-0427
4 Abbe horizontal length measuring machines Calibration — Length
0 mm to 100 mm · CMC 1,0 µm
Length
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-0405
5 Reference foils Calibration — Length
0 mm to 4 mm · CMC Q[1,6; 1,3∙L] µm
Length
Internal procedure; At permanent location (S) Internal procedure Qliw-0459
6 Vernier depth gauges Calibration — Length
0 mm do 150 mm · CMC 8 µm 0 mm do 300 mm · CMC 11 µm 0 mm to 600 mm · CMC 18 µm 0 mm to 1000 mm · CMC 29 µm
Length
Internal procedure; At permanent location (S) Internal procedure Qliw-0421
7 Micrometer heads Calibration — Length
– resolution 0,001 mm — 0 mm to 50 mm · CMC 2,2 µm – resolution 0,01 mm — 0 mm to 50 mm · CMC 7,7 µm
Length
Internal procedure; At permanent location (S) Internal procedure Qliw-0406
8 Coating thickness gauges Calibration — Length
0 µm to 1250 µm · CMC 4,2 µm
Length
Internal procedure; At permanent location (S) Internal procedure Qliw-0460
9 External micrometers Calibration — Length
0 mm to 75 mm · CMC (3,6 + 0,01∙L) µm
Length
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-0429
10 Universal measuring microscopes Calibration — Length
200 mm x 100 mm · CMC 2,2 µm
Length
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-0401
11 Toolmaker's measuring microscopes Calibration — Length
200 mm x 200 mm · CMC 2,3 µm
Length
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-0402
12 Setting rings Calibration — Length
1 mm to 30 mm · CMC 0,0017 mm 30 mm to 100 mm · CMC 0,0018 mm 100 mm to 250 mm · CMC 0,0020 mm
Length
Internal procedure; At permanent location (S) Internal procedure Qliw-0458
13 Profile projectors Calibration — Length
200 mm x 200 mm · CMC 2,3 µm
Length
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-0403
14 Rigid rules
Semi-rigid rules
Measuring tapes
Calibration — Length
up to 3000 mm · CMC Q[0,21; 0,03∙L] mm
Length
Internal procedure; At permanent location (S) Internal procedure Qliw-0441
15 Test sieves Calibration — Length
0,020 mm to 10 mm · CMC 7,3 µm
Length
Internal procedure; Measurement of sieve aperture size with a universal microscope; At permanent location (S) Internal procedure Qliw-0457 based on the standards PN-ISO 3310-1:2000 PN-ISO 3310-2:2000
16 Test sieves Calibration — Length
over 10 mm to 125 mm · CMC 124 µm
Length
Internal procedure; Measurement of sieve aperture size with a vernier caliper; At permanent location (S) Internal procedure Qliw-0457 based on the standards PN-ISO 3310-1:2000 PN-ISO 3310-2:2000
17 Plug gauges Calibration — Length
1 mm to 30 mm · CMC 1,2 µm 30 mm to 60 mm · CMC 1,4 µm 60 mm to 100 mm · CMC 1,8 µm
Length
Internal procedure; At permanent location (S) Internal procedure Qliw-0428
18 Vernier calipers Calibration — Length
0 mm to 500 mm · CMC (12 + 12∙L) µm
Length
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-0420
19 Feeler gauges Calibration — Length
0,02 mm to 2 mm · CMC 0,0033 mm
Length
Internal procedure; At permanent location (S) Internal procedure Qliw-0451
20 Dial bore gauges Calibration — Length
0 mm to 18 mm · CMC 3,8 µm 18 mm to 160 mm · CMC 5,5 µm 160 mm to 380 mm · CMC 10,7 µm 380 mm to 450 mm · CMC 12,5 µm
Length
Internal procedure; At permanent location (S) Internal procedure Qliw-0423
21 Two-point inside micrometers Calibration — Length
50 mm to 100 mm · CMC 6,2 µm 100 mm to 200 mm · CMC 6,7 µm 200 mm to 300 mm · CMC 7,3 µm 300 mm to 400 mm · CMC 8,2 µm 400 mm to 500 mm · CMC 9,2 µm
Length
Internal procedure; Calibration with a horizontal length measuring machine; At permanent location (S) Internal procedure Qliw-0432
22 Three-point inside micrometers Calibration — Length
5 mm do 50 mm · CMC 3,7 µm 50 mm do 100 mm · CMC 3,9 µm 100 mm do 150 mm · CMC 4,2 µm 150 mm to 175 mm · CMC 4,3 µm
Length
Internal procedure; At permanent location (S) Internal procedure Qliw-0432
23 Digital height gauges with resolution: Calibration — Length
– 0,1 mm — 0 mm to 1000 mm · CMC Q[58,2; 6,6∙L] µm – 0,01 mm, 0,02 mm, 0,05 mm — 0 mm to 1000 mm · CMC Q[29,8; 6,6∙L] µm – 0,001 mm, 0,002 mm, 0,005 mm — 0 mm to 1000 mm · CMC Q[3,9; 6,6∙L] µm – 0,0001 mm, 0,0002 mm, 0,0005 mm — 0 mm to 1000 mm · CMC Q[3,9; 6,6∙L] µm
Length
Internal procedure; At permanent location (S) Internal procedure Qliw-0461
24 Vernier height gauges Calibration — Length
0 mm do 150 mm · CMC 8 µm 0 mm do 300 mm · CMC 11 µm 0 mm to 600 mm · CMC 18 µm 0 mm to 1000 mm · CMC 29 µm
Length
Internal procedure; Calibration with gauge blocks; At permanent location (S) Internal procedure Qliw-0422
25 Radius gauges Calibration — Length
1 mm to 25 mm · CMC 12 µm
Length
Internal procedure; At permanent location (S) Internal procedure Qliw-0453
26 Setting standards for external dimensions Calibration — Length
up to 500 mm · CMC Q[2,4; 0,008∙L] µm
Length
Internal procedure; At permanent location (S) Internal procedure Qliw-0470
27 Universal bevel protractors Calibration — Angle
4 x 90° · CMC 5’
Angle
Internal procedure; At permanent location (S) Internal procedure Qliw-0433
28 90º try squares Calibration — Angle
longer arm up to 300 mm · CMC 0,0039 mm
Angle
Internal procedure; At permanent location (S) Internal procedure Qliw-0434
29 90º cylindrical squares Calibration — Angle
up to 500 mm · CMC 3,8 µm
Angle
Internal procedure; At permanent location (S) Internal procedure Qliw-0435
30 Universal measuring microscopes Calibration — Angle
0° to 360° · CMC 2’
Angle
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-0401
31 Toolmaker's measuring microscopes Calibration — Angle
0° to 360° · CMC 2’
Angle
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-0402
32 Johansson angle gauge blocks Calibration — Angle
up to 360° · CMC 3,8"
Angle
Internal procedure; At permanent location (S) Internal procedure Qliw-0407
33 Wringing angle gauge blocks Calibration — Angle
up to 360° · CMC 2,6"
Angle
Internal procedure; At permanent location (S) Internal procedure Qliw-0407
34 Bar spirit levels Calibration — Angle
- error of the scale interval value — 0 mm/m to 20 mm/m /0,02 mm · CMC 0,016 mm/m - error of the scale interval value — 0 mm/m to 20 mm/m /0,05 mm · CMC 0,017 mm/m - error of the scale interval value — 0 mm/m to 20 mm/m /0,1 mm · CMC 0,019 mm/m - zero setting error — 0 mm/m to 20 mm/m · CMC 0,08∙dₑ
Angle
Internal procedure; At permanent location (S) Internal procedure Qliw-0438
35 Profile projectors Calibration — Angle
0° to 360° · CMC 2’
Angle
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-0403
36 Optical flats Calibration — Length (surface geometry)
- flatness deviation — Ø up to 100 mm · CMC 0,06 µm
Length (surface geometry)
Internal procedure; At permanent location (S) Internal procedure Qliw-0440
37 Analogue voltmeters Calibration — DC voltage
1 mV to 10 mV · CMC 1,3 % 10 mV to 100 mV · CMC 0,07 % 0,1 V to 1000 V · CMC 0,03 % 1000 V to 6000 V · CMC 2,0 %
DC voltage
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-2401
38 Digital voltmeters
Multimeters
Calibration — DC voltage
1 mV to 10 mV · CMC 1,3 % 10 mV to 100 mV · CMC 0,07 % 0,1 V to 1000 V · CMC 0,03 % 1000 V to 6000 V · CMC 2,0 %
DC voltage
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-2411 based on EURAMET cg-15 v. 3.0
39 Power supplies Calibration — DC voltage
0,01V to 0,1V · CMC 1,4 · 10⁻⁴ · U + 5,8 µV 0,1V to 1V · CMC 1,4 · 10⁻⁴ · U + 58 µV 1V to 10V · CMC 1,4 · 10⁻⁴ · U + 0,58 mV 10V to 100V · CMC 1,4 · 10⁻⁴ · U + 5,8 mV
DC voltage
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-2411
40 Analogue ammeters Calibration — DC current
1 mA to 100 mA · CMC 1,2 % 0,1 A to 1 A · CMC 0,04 % 1 A to 10 A · CMC 0,06 %
DC current
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-2401
41 Digital ammeters
multimeters
Calibration — DC current
1 mA to 100 mA · CMC 1,2 % 0,1 A to 1 A · CMC 0,04 % 1 A to 10 A · CMC 0,06 %
DC current
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-2411 based on EURAMET cg-15 v. 3.0
42 Power supplies Calibration — DC current
0,1 A to 10 A · CMC 0,5 %
DC current
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-2411
43 Analogue voltmeters Calibration — AC voltage
50 Hz — 1 mV to 10 mV · CMC 0,7 % 50 Hz — 10 mV to 1000 V · CMC 0,07 % 50 Hz — 1000 V to 6000 V · CMC 2,0 %
AC voltage
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-2401
44 Digital voltmeters
Multimeters
Calibration — AC voltage
50 Hz — 1 mV to 10 mV · CMC 0,7 % 50 Hz — 10 mV to 1000 V · CMC 0,07 % 50 Hz — 1000 V to 6000 V · CMC 2,0 %
AC voltage
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-2411 based on EURAMET cg-15 v. 3.0
45 Breakdown voltage meters
Breakdown testers
Power supplies
Calibration — AC voltage
50 Hz — 100 V to 500 V · CMC 0,7 % 50 Hz — 500 V to 6000 V · CMC 2,0 %
AC voltage
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-2411
46 Analogue ammeters Calibration — AC current
50 Hz — 1 A to 100 mA · CMC 1,3 % 50 Hz — 0,1 A to 1 A · CMC 0,07 % 50 Hz — 1 A to 10 A · CMC 0,2 %
AC current
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-2401
47 Digital ammeters
Multimeters
Calibration — AC current
50 Hz — 1 A to 100 mA · CMC 1,3 % 50 Hz — 0,1 A to 1 A · CMC 0,07 % 50 Hz — 1 A to 10 A · CMC 0,2 %
AC current
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-2411 based on EURAMET cg-15 v. 3.0
48 Analogue ohmmeters Calibration — DC resistance
0,01 Ω to 0,1 Ω · CMC 0,006 Ω 1 Ω to 10 Ω · CMC 0,05 % 10 Ω to 1 kΩ · CMC 0,007 % 1 kΩ to 100 kΩ · CMC 0,005 % 100 kΩ to 100 MΩ · CMC 0,01 %
DC resistance
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-2402
49 Digital ohmmeters Calibration — DC resistance
0,01 Ω to 0,1 Ω · CMC 0,006 Ω 1 Ω to 10 Ω · CMC 0,05 % 10 Ω to 1 kΩ · CMC 0,007 % 1 kΩ to 100 kΩ · CMC 0,005 % 100 kΩ to 100 MΩ · CMC 0,01 %
DC resistance
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure Qliw-2410 based on EURAMET cg-15 v. 3.0
50 Testing machines for static tests: Calibration — Force
- for tensile forces — 0,1 N to 500 kN · CMC 0,12 %; 0,24 % - for compressive forces — 0,1 N to 1000 kN · CMC 0,12 %; 0,24 %
Force
At permanent location (S) and outside of it (P) PN-EN ISO 7500-1:2018
51 Technological equipment: Calibration — Force
- for tensile forces — 0,1 N to 500 kN · CMC 0,12 %; 0,24 % - for compressive forces — 0,1 N to 1000 kN · CMC 0,12 %; 0,24 %
Force
At permanent location (S) and outside of it (P) PN-EN ISO 7500-1:2018
52 Torque wrenches Calibration — Torque
0,2 Nm to 1100 Nm · CMC 0,9 %
Torque
At permanent location (S) and outside of it (P) PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017
53 Rotary tools Calibration — Torque
1 Nm to 5 Nm · CMC 1,5% 7,5 Nm to 75 Nm · CMC 1,5 %
Torque
At permanent location (S) and outside of it (P) PN-ISO 5393:1997
54 Torque screwdrivers Calibration — Torque
0,2 Nm to 10 Nm · CMC 0,9 %
Torque
At permanent location (S) and outside of it (P) PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017
55 Rockwell hardness testers: Calibration — Hardness
- hardness — 20 HRA to 95 HRA · CMC 0,5 HRA - hardness — 10 HRB to 85 HRB · CMC 1,2 HRB - hardness — (85 HRB to 100) HRB · CMC 0,6 HRB - hardness — 10 HRC to 70 HRC · CMC 0,5 HRC - hardness — 70 HR15N to 94 HR15N · CMC 0,6 HR15N - hardness — 42 HR30N to 86 HR30N · CMC 0,6 HR30N - hardness — 20 HR45N to 77 HR45N · CMC 0,6 HR45N - hardness — 67 HR15T to 93 HR15T · CMC 1,0 HR15T - hardness — 29 HR30T to 82 HR30T · CMC 1,0 HR30T - hardness — 10 HR45T to 72 HR45T · CMC 1,0 HR45T - force — 29,42 N to 1471 N · CMC 0,24 %
Hardness
At permanent location (S) and outside of it (P) PN-EN ISO 6508-2:2024
56 Vickers hardness testers: Calibration — Hardness
- hardness — 100 HV 0,2 to 900 HV 0,2 · CMC 4,5 % - hardness — 100 HV 0,3 to 900 HV 0,3 · CMC 4,0 % - hardness — 100 HV 0,5 to 900 HV 0,5 · CMC 4,0 % - hardness — 100 HV 1 to 900 HV 1 · CMC 2,2 % - hardness — 100 HV 2 to 900 HV 2 · CMC 1,8 % - hardness — 100 HV 3 to 900 HV 3 · CMC 1,6 % - hardness — 100 HV 5 to 900 HV 5 · CMC 1,5 % - hardness — 100 HV 10 to 900 HV 10 · CMC 1,3 % - hardness — 100 HV 30 to 900 HV 30 · CMC 2,0 % - force — 0,9807 N to 980,7 N · CMC 0,24 % - length — 0 mm to 1 mm · CMC 0,0005 mm
Hardness
At permanent location (S) and outside of it (P) PN-EN ISO 6507-2:2018
57 Brinell hardness testers: Calibration — Hardness
- hardness — 60 to 200 HBW 2,5 / 62,5 · CMC 1,5 % - hardness — 100 to 600 HBW 2,5 / 187,5 · CMC 1,0 % - hardness — 100 to 600 HBW 5 / 750 · CMC 1,5 % - hardness — 100 to 600 HBW 10 / 3000 · CMC 1,2 % - force — 612,29 N to 29420 N · CMC 0,24 % - length — 0 mm to 1 mm · CMC 0,0005 mm - length — 0 mm to 10 mm · CMC 0,0010 mm
Hardness
At permanent location (S) and outside of it (P) PN-EN ISO 6506-2:2019
58 Electrical thermometers (including electronic) Calibration — Temperature (electrical thermometry)
160 °C to 200 °C · CMC 1,0 °C
Temperature (electrical thermometry)
Internal procedure; At permanent location (S) Internal procedure Qliw-2405

Reference standards (44)

EURAMET cg-15 v. 3.0
PN-EN ISO 6506-2:2019
PN-EN ISO 6507-2:2018
PN-EN ISO 6508-2:2024
PN-EN ISO 6789-1:2017
PN-EN ISO 6789-2:2017
PN-EN ISO 7500-1:2018
PN-ISO 3310-1:2000
PN-ISO 3310-2:2000
PN-ISO 5393:1997
Qliw-0401
Qliw-0402
Qliw-0403
Qliw-0405
Qliw-0406
Qliw-0407
Qliw-0420
Qliw-0421
Qliw-0422
Qliw-0423
Qliw-0427
Qliw-0428
Qliw-0429
Qliw-0432
Qliw-0433
Qliw-0434
Qliw-0435
Qliw-0438
Qliw-0440
Qliw-0441
Qliw-0451
Qliw-0453
Qliw-0457
Qliw-0458
Qliw-0459
Qliw-0460
Qliw-0461
Qliw-0462
Qliw-0470
Qliw-2401
Qliw-2402
Qliw-2405
Qliw-2410
Qliw-2411

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20001