🇵🇱 WODOCIĄGI KĘPIŃSKIE Sp. z o.o. PL

PCA AB 996 • Baranów, Poland • 36 methods

Water & wastewaterMicrobiology

WODOCIĄGI KĘPIŃSKIE Sp. z o.o. is a laboratory accredited by PCA under number AB 996 (Baranów, Poland). Its accreditation scope covers 36 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water, Wastewater, Wastewater, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Electrochemical method.

At a glance

  • Accreditation number: PCA AB 996
  • Methods in scope: 36
  • Types of test objects: 4
  • Techniques used: 13
  • City: Baranów, Poland
Accreditation number
AB 996
Accreditation body
PCA
Address
ul. Wrocławska 40, 63-600 Kępno, LABORATORIUM, ul. Ekologiczna 8, 63-604 Baranów
City
Baranów, Poland

What this laboratory tests (4)

Analytical techniques used (13)

Accreditation scope — test methods (36)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (2,0 - 40) oC
Manual and automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
2 Water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken
Range (2,0 - 60) oC
PN-ISO 5667-5:2017-10 | PN-77/C-04584
3 Water Sampling from rivers and streams for chemical and physical testing Manual method PN-EN ISO 5667-6:2016-12
4 Water Sampling for microbiological testing PN-EN ISO 19458:2007 z wył. pkt 4.4.3, 4.4.4, 4.4.5 i 4.4.6
5 Water, Wastewater pH
Range 4,0 - 10,0
Potentiometric method PN-EN ISO 10523:2012
6 Water, Wastewater Total suspended solids (TSS)
Range (2,0 - 1600) mg/l
Gravimetric method PN-EN 872:2007 +Ap1:2007
7 Water, Wastewater Dissolved oxygen concentration
Range (0,50 - 15) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04
8 Water, Wastewater Biochemical oxygen demand - BOD5
Range (2 - 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
9 Water, Wastewater Biochemical oxygen demand - BOD5
Range (0,5 - 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
10 Water, Wastewater Total phosphorus concentration
Range (0,050 - 25) mg/l
Spectrophotometric method Test Merck Nr 1.14543.0001 Wyd. 7.2025 Nr 1.14729.0001 Wyd. 8.2024
11 Water, Wastewater Total nitrogen concentration
Range (0,50 - 150) mg/l
Spectrophotometric method Test Merck Nr 1.14537.0001 Wyd. 9.2024 Nr 1.14763.0001 Wyd. 5.2025
12 Water, Wastewater Ammonium nitrogen concentration
Range (2,0 - 150) mg/l
Spectrophotometric method Test Merck Nr 1.00683.0001 Wyd. 5.2025
13 Water, Wastewater Chemical oxygen demand - COD-Cr
Range (4,0 - 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
14 Water, Wastewater Concentration of substances extractable with petroleum ether
Range (5,0 - 1000) mg/l
Gravimetric method PB-19 wydanie 2 z dnia 13.11.2018
15 Water, Wastewater Phenol index
Range (0,10 - 3,0) mg/l
Spectrophotometric method PN-ISO 6439:1994 metoda A
16 Water, Wastewater Phenol index
Range (0,006 - 0,10) mg/l
Spectrophotometric method PN-ISO 6439:1994 metoda B
17 Water, Wastewater Ammonium ion concentration
Range (0,025 - 2,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
18 Water, Wastewater Total iron concentration
Range (20 - 5000) μg/l
Spectrophotometric method Test Merck Nr 1.14761.0001 Wyd. 5.2025
19 Water, Wastewater Nitrite concentration
Range (0,20 - 3,28) mg/l
Spectrophotometric method Test Merck Nr 1.14776.0001 Wyd. 12.2024
20 Water, Wastewater Chloride concentration
Range (5,0 - 400) mg/l
Titrimetric method PN-ISO 9297:1994
21 Water, Wastewater Sulfate concentration
Range (5,0 - 250) mg/l
Spectrophotometric method Test Merck Nr 1.14548.0001 Wyd. 5.2024
22 Water Turbidity
Range (0,10 - 20) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
23 Water Electrical conductivity
Range (147 - 1413) μS/cm
Conductometric method PN-EN 27888:1999
24 Water Manganese concentration
Range (10 - 2000) μg/l
Spectrophotometric method Test Merck Nr 1.14770.0001 Wyd. 8.2025
25 Water Nitrate concentration
Range (1,0 - 110) mg/l
Spectrophotometric method Test Merck Nr 1.09713.0001 Wyd. 5.2025
26 Water Colour
Range (2,5 - 20) mg/l
Visual method PN-EN ISO 7887:2012 metoda D +Ap1:2015-06
27 Water Permanganate index
Range (0,50 - 10) mg/l
Titrimetric method PN-EN ISO 8467:2001
28 Water Total viable count at 22 oC Plate method (pour plate) PN-EN ISO 6222:2004
29 Water Total viable count at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004
30 Water Most probable number of, Eschericha coli MPN method PN-EN ISO 9308-2:2014-06
31 Water Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
32 Water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12+ A1:2017-04
33 Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12+ A1:2017-04
34 Water Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
35 Water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
36 Water Legionella sp. count Matrix A Procedure 5 (BCYE medium), Procedure 7 (GVPC medium)
Range od 1 jtk/100 ml from 1 CFU/1000 ml
Membrane filtration method PN-EN ISO 11731:2017-08 + Ap1:2019-12

Reference standards (34)

PB-19 wydanie 2 z dnia 13.11.2018
PN-77/C-04584
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007 +Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 + Ap1:2019-12
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wył. pkt 4.4.3, 4.4.4, 4.4.5 i 4.4.6
PN-EN ISO 5667-6:2016-12
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda D +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12+ A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6439:1994 metoda A
PN-ISO 6439:1994 metoda B
PN-ISO 7150-1:2002
PN-ISO 9297:1994
Test Merck Nr 1.00683.0001 Wyd. 5.2025
Test Merck Nr 1.09713.0001 Wyd. 5.2025
Test Merck Nr 1.14537.0001 Wyd. 9.2024 Nr 1.14763.0001 Wyd. 5.2025
Test Merck Nr 1.14543.0001 Wyd. 7.2025 Nr 1.14729.0001 Wyd. 8.2024
Test Merck Nr 1.14548.0001 Wyd. 5.2024
Test Merck Nr 1.14761.0001 Wyd. 5.2025
Test Merck Nr 1.14770.0001 Wyd. 8.2025
Test Merck Nr 1.14776.0001 Wyd. 12.2024