🇵🇱 WODOCIĄGI KĘPIŃSKIE Sp. z o.o. PL
Water & wastewaterMicrobiology
WODOCIĄGI KĘPIŃSKIE Sp. z o.o. is a laboratory accredited by PCA under number AB 996 (Baranów, Poland). Its accreditation scope covers 36 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water, Wastewater, Wastewater, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Electrochemical method.
At a glance
- Accreditation number: PCA AB 996
- Methods in scope: 36
- Types of test objects: 4
- Techniques used: 13
- City: Baranów, Poland
- Accreditation number
- AB 996
- Accreditation body
- PCA
- Address
- ul. Wrocławska 40, 63-600 Kępno, LABORATORIUM, ul. Ekologiczna 8, 63-604 Baranów
- City
- Baranów, Poland
What this laboratory tests (4)
- Water — 17 methods
- Water, Wastewater — 17 methods
- Wastewater — 1 method
- Water intended for human consumption — 1 method
Analytical techniques used (13)
- Spectrophotometric method — 12 methods
- Membrane filtration method — 5 methods
- Electrochemical method — 3 methods
- Gravimetric method — 2 methods
- MPN method — 2 methods
- Plate method (pour plate) — 2 methods
- Titrimetric method — 2 methods
- Conductometric method — 1 method
- Manual and automatic method — 1 method
- Manual method — 1 method
- Nephelometric method — 1 method
- Potentiometric method — 1 method
- Visual method — 1 method
Accreditation scope — test methods (36)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Wastewater | Sampling for chemical and physical testing Temperature of the collected wastewater sample Range (2,0 - 40) oC |
Manual and automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 2 | Water intended for human consumption | Sampling for chemical and physical testing Temperature of the water sample taken Range (2,0 - 60) oC |
PN-ISO 5667-5:2017-10 | PN-77/C-04584 | ||
| 3 | Water | Sampling from rivers and streams for chemical and physical testing | Manual method | PN-EN ISO 5667-6:2016-12 | |
| 4 | Water | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wył. pkt 4.4.3, 4.4.4, 4.4.5 i 4.4.6 | ||
| 5 | Water, Wastewater | pH Range 4,0 - 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 6 | Water, Wastewater | Total suspended solids (TSS) Range (2,0 - 1600) mg/l |
Gravimetric method | PN-EN 872:2007 +Ap1:2007 | |
| 7 | Water, Wastewater | Dissolved oxygen concentration Range (0,50 - 15) mg/l O2 |
Electrochemical method | PN-EN ISO 5814:2013-04 | |
| 8 | Water, Wastewater | Biochemical oxygen demand - BOD5 Range (2 - 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 9 | Water, Wastewater | Biochemical oxygen demand - BOD5 Range (0,5 - 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 10 | Water, Wastewater | Total phosphorus concentration Range (0,050 - 25) mg/l |
Spectrophotometric method | Test Merck Nr 1.14543.0001 Wyd. 7.2025 Nr 1.14729.0001 Wyd. 8.2024 | |
| 11 | Water, Wastewater | Total nitrogen concentration Range (0,50 - 150) mg/l |
Spectrophotometric method | Test Merck Nr 1.14537.0001 Wyd. 9.2024 Nr 1.14763.0001 Wyd. 5.2025 | |
| 12 | Water, Wastewater | Ammonium nitrogen concentration Range (2,0 - 150) mg/l |
Spectrophotometric method | Test Merck Nr 1.00683.0001 Wyd. 5.2025 | |
| 13 | Water, Wastewater | Chemical oxygen demand - COD-Cr Range (4,0 - 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 14 | Water, Wastewater | Concentration of substances extractable with petroleum ether Range (5,0 - 1000) mg/l |
Gravimetric method | PB-19 wydanie 2 z dnia 13.11.2018 | |
| 15 | Water, Wastewater | Phenol index Range (0,10 - 3,0) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 metoda A | |
| 16 | Water, Wastewater | Phenol index Range (0,006 - 0,10) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 metoda B | |
| 17 | Water, Wastewater | Ammonium ion concentration Range (0,025 - 2,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 18 | Water, Wastewater | Total iron concentration Range (20 - 5000) μg/l |
Spectrophotometric method | Test Merck Nr 1.14761.0001 Wyd. 5.2025 | |
| 19 | Water, Wastewater | Nitrite concentration Range (0,20 - 3,28) mg/l |
Spectrophotometric method | Test Merck Nr 1.14776.0001 Wyd. 12.2024 | |
| 20 | Water, Wastewater | Chloride concentration Range (5,0 - 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 21 | Water, Wastewater | Sulfate concentration Range (5,0 - 250) mg/l |
Spectrophotometric method | Test Merck Nr 1.14548.0001 Wyd. 5.2024 | |
| 22 | Water | Turbidity Range (0,10 - 20) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 23 | Water | Electrical conductivity Range (147 - 1413) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 24 | Water | Manganese concentration Range (10 - 2000) μg/l |
Spectrophotometric method | Test Merck Nr 1.14770.0001 Wyd. 8.2025 | |
| 25 | Water | Nitrate concentration Range (1,0 - 110) mg/l |
Spectrophotometric method | Test Merck Nr 1.09713.0001 Wyd. 5.2025 | |
| 26 | Water | Colour Range (2,5 - 20) mg/l |
Visual method | PN-EN ISO 7887:2012 metoda D +Ap1:2015-06 | |
| 27 | Water | Permanganate index Range (0,50 - 10) mg/l |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 28 | Water | Total viable count at 22 oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 29 | Water | Total viable count at 36 oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 30 | Water | Most probable number of, Eschericha coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 31 | Water | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 32 | Water | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12+ A1:2017-04 | |
| 33 | Water | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12+ A1:2017-04 | |
| 34 | Water | Enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 35 | Water | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 36 | Water | Legionella sp. count Matrix A Procedure 5 (BCYE medium), Procedure 7 (GVPC medium) Range od 1 jtk/100 ml from 1 CFU/1000 ml |
Membrane filtration method | PN-EN ISO 11731:2017-08 + Ap1:2019-12 | |
Reference standards (34)
PB-19 wydanie 2 z dnia 13.11.2018
PN-77/C-04584
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007 +Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 + Ap1:2019-12
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wył. pkt 4.4.3, 4.4.4, 4.4.5 i 4.4.6
PN-EN ISO 5667-6:2016-12
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda D +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12+ A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6439:1994 metoda A
PN-ISO 6439:1994 metoda B
PN-ISO 7150-1:2002
PN-ISO 9297:1994
Test Merck Nr 1.00683.0001 Wyd. 5.2025
Test Merck Nr 1.09713.0001 Wyd. 5.2025
Test Merck Nr 1.14537.0001 Wyd. 9.2024 Nr 1.14763.0001 Wyd. 5.2025
Test Merck Nr 1.14543.0001 Wyd. 7.2025 Nr 1.14729.0001 Wyd. 8.2024
Test Merck Nr 1.14548.0001 Wyd. 5.2024
Test Merck Nr 1.14761.0001 Wyd. 5.2025
Test Merck Nr 1.14770.0001 Wyd. 8.2025
Test Merck Nr 1.14776.0001 Wyd. 12.2024