🇵🇱 EKOSAN STALOWA WOLA Sp. z o.o. PL
Water & wastewater
EKOSAN STALOWA WOLA Sp. z o.o. is a laboratory accredited by PCA under number AB 986 (Stalowa Wola, Poland). Its accreditation scope covers 24 test methods in the following areas: Water & wastewater. Test objects include: Water, wastewater, Water, wastewater, water intended for human consumption, Rainwater, snowmelt water, Wastewater. Most frequently used techniques: Spectrophotometric method, Gravimetric method, Titrimetric method.
At a glance
- Accreditation number: PCA AB 986
- Methods in scope: 24
- Types of test objects: 5
- Techniques used: 7
- City: Stalowa Wola, Poland
- Accreditation number
- AB 986
- Accreditation body
- PCA
- Address
- LABORATORIUM OCHRONY ŚRODOWISKA, ul. Działkowa 2, 37 - 450 Stalowa Wola
- City
- Stalowa Wola, Poland
What this laboratory tests (5)
- Water, wastewater — 12 methods
- Water, wastewater, water intended for human consumption — 9 methods
- Rainwater, snowmelt water — 1 method
- Wastewater — 1 method
- Water — 1 method
Analytical techniques used (7)
- Spectrophotometric method — 10 methods
- Gravimetric method — 3 methods
- Titrimetric method — 3 methods
- Manual method — 2 methods
- Conductometric method — 1 method
- Optical method — 1 method
- Potentiometric method — 1 method
Accreditation scope — test methods (24)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water | Sampling for chemical and physical testing Temperature of the water sample taken Range (0,1 – 50,0) oC |
PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 6.1.2, 6.2,6.3 | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 i 7.6 | PN-77/C-04584 | ||
| 2 | Rainwater, snowmelt water | Sampling for chemical and physical testing | Manual method | PN-ISO 5667-10:2021-11 | |
| 3 | Wastewater | Sampling for chemical and physical testing Temperature of the collected wastewater sample Range (0,1 – 50,0) oC |
Manual method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 4 | Water, wastewater, water intended for human consumption | pH Range 4,0 − 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 5 | Water, wastewater, water intended for human consumption | Electrical conductivity Range (100 − 2500) μS/cm |
Conductometric method | P N - E N 27888:1999 | |
| 6 | Water, wastewater, water intended for human consumption | Iron concentration Range (0,010 – 50,0) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 7 | Water, wastewater, water intended for human consumption | Sulfate concentration Range (10 − 5000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 8 | Water, wastewater, water intended for human consumption | Nitrate nitrogen concentration Range (0,100 – 25,0) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 9 | Water, wastewater, water intended for human consumption | Nitrite nitrogen concentration Range (0,010 − 2,5) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 10 | Water, wastewater, water intended for human consumption | Ammonium nitrogen concentration Range (0,10 − 2,0) mg/l |
Spectrophotometric method | PN-C-04576-4:1994 | |
| 11 | Water, wastewater, water intended for human consumption | Ammonium nitrogen concentration Range (0,2 − 1000) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 12 | Water, wastewater, water intended for human consumption | Chloride concentration Range (5,0 − 1000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 13 | Water, wastewater | Total chromium concentration Range (0,020 – 10,0) mg/l |
Spectrophotometric method | PN-77/C-04604/02 | |
| 14 | Water, wastewater | Chromium(VI) concentration Range (0,020 – 10,0) mg/l |
Spectrophotometric method | PN-77/C-04604/08 | |
| 15 | Water, wastewater | Chromium (III) concentration (calculated) | PN-77/C-04604/08 | ||
| 16 | Water, wastewater | Biochemical oxygen demand BOD5 Range (3 – 2000) mg/l O2 |
Optical method | PN-EN ISO 5815-1:2019-12 | |
| 17 | Water, wastewater | Chemical oxygen demand COD Range (10,0 – 1000) mg/l O2 |
Spectrophotometric method | P N -ISO 15705:2005 | |
| 18 | Water, wastewater | Orthophosphate concentration Range (0,050 – 5,00) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010 | |
| 19 | Water, wastewater | Total phosphorus concentration Range (0,050 – 50,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt 7 i 8 +Ap1:2010+Ap2:2010 | |
| 20 | Water, wastewater | Substances extractable with petroleum ether Range (0,5 − 50) mg/l |
Gravimetric method | PN-86/C-04573/01 | |
| 21 | Water, wastewater | Kjeldahl nitrogen concentration Range (1,0 − 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 22 | Water, wastewater | Total nitrogen concentration (calculated) | IB/13/ZBWŚ wydanie 3 z dnia 23.07.2024 r. | ||
| 23 | Water, wastewater | Total suspended solids (TSS) Range (2,0 − 1000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 24 | Water, wastewater | Phenol index Range (0,008 − 0,10) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 metoda B | |
Reference standards (24)
IB/13/ZBWŚ wydanie 3 z dnia 23.07.2024 r.
P N - E N 27888:1999
P N -ISO 15705:2005
PN-77/C-04584
PN-77/C-04604/02
PN-77/C-04604/08
PN-82/C-04576/08
PN-86/C-04573/01
PN-C-04576-4:1994
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 i 7.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt 7 i 8 +Ap1:2010+Ap2:2010
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 6.1.2, 6.2,6.3
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 6439:1994 metoda B
PN-ISO 9280:2002
PN-ISO 9297:1994