🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL
Water & wastewaterMicrobiology
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 984 (Września, Poland). Its accreditation scope covers 60 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Water, wastewater, Water, Sewage sludge. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Gravimetric method.
At a glance
- Accreditation number: PCA AB 984
- Methods in scope: 60
- Types of test objects: 6
- Techniques used: 11
- City: Września, Poland
- Accreditation number
- AB 984
- Accreditation body
- PCA
- Address
- ul. Miłosławska 8, 62-300 Września, LABORATORIUM ANALIZ WODY I ŚCIEKÓW, ul. Sikorskiego 42
- City
- Września, Poland
What this laboratory tests (6)
- Water intended for human consumption — 23 methods
- Water, wastewater — 18 methods
- Water — 9 methods
- Sewage sludge — 4 methods
- Wastewater — 4 methods
- Surface water — 2 methods
Analytical techniques used (11)
- Spectrophotometric method — 20 methods
- Titrimetric method — 9 methods
- Gravimetric method — 7 methods
- Electrochemical method — 3 methods
- Membrane filtration method — 3 methods
- Potentiometric method — 3 methods
- Conductometric method — 2 methods
- Nephelometric method — 2 methods
- Simplified method, paired, non-forced choice — 2 methods
- Manual and automatic method — 1 method
- Plate method (pour plate) — 1 method
Laboratory locations
- PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. (main site) — ul. Miłosławska 8, 62-300 Września
- WATER AND WASTEWATER ANALYSIS LABORATORY — ul. Sikorskiego 42, 62-300 Września
Certificate information
- Issue date
- 02.11.2026
- Issue no.
- 19
Accreditation scope — test methods (60)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Water and Wastewater Analysis Laboratory | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing (including sensory testing) Temperature Range (3,0 – 50) °C |
PN-ISO 5667-5:2017-10 excluding cl. 6.5 | PN-77/C-04584 | ||
| 2 | Surface water | Sampling for chemical and physical testing Temperature Range (3,0 – 50) °C |
PN-ISO 5667-4:2017-10 excluding cl. 13, 14, 15 and 16 | PN-77/C-04584 | ||
| 3 | Surface water | Sampling for chemical and physical testing | PN-EN ISO 5667-6:2016-12 excluding cl. 7.2, 7.5, 7.6, 8.2, 9.3 and 9.4 | ||
| 4 | Wastewater | Sampling for chemical and physical testing Temperature of the collected wastewater sample Range (3,0 – 50) °C |
Manual and automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 5 | Water | Total content of calcium and magnesium (total hardness) Range (10 – 1000) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 6 | Water | Permanganate index Range (1,0 – 12) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 7 | Water | Colour Range (5 – 110) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 Method C | |
| 8 | Water | Electrical conductivity Range (100 – 2500) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 9 | Water | Manganese concentration Range (0,015 – 1,50) mg/l |
Spectrophotometric method | PN-92/C-04590/03 | |
| 10 | Water | Turbidity Range (0,20 – 15) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 11 | Water | Dissolved oxygen concentration Range (0,5 – 15) mg/l |
Electrochemical method | PN-EN ISO 5814:2013-04 | |
| 12 | Water | Free chlorine concentrations Range (0,02 – 2,0) mg/l |
Spectrophotometric method | PBL-30 issue 03 of 24 May 2019 | based on Hach Lange test No. 21055-60 | |
| 13 | Water | Total alkalinity Range (0,40 – 20) mmol/l |
Titrimetric method | PN-EN ISO 9963-1:2001+Ap1:2004 | |
| 14 | Water, wastewater | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 15 | Water, wastewater | Total suspended solids (TSS) Range (5,0 – 5000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 16 | Water, wastewater | Chloride concentration Range (5,0 – 5000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 17 | Water, wastewater | Ammonium nitrogen concentration Range (0,05 – 10) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 18 | Water, wastewater | Nitrite nitrogen concentration Range (0,008 – 10) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 19 | Water, wastewater | Nitrate nitrogen concentration Range (0,10 – 40) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 20 | Water, wastewater | Total phosphorus concentration Range (0,10 – 60) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 | |
| 21 | Water, wastewater | Biochemical oxygen demand BOD5 Range (3 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 22 | Water, wastewater | Biochemical oxygen demand BOD5 Range (0,5 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 23 | Water, wastewater | Anionic detergent concentration Range (0,10 – 45) mg/l |
Spectrophotometric method | PN-EN 903:2002 | |
| 24 | Water, wastewater | Concentration of substances extractable with petroleum ether Range (20 – 1000) mg/l |
Gravimetric method | PN-86/C-04573/01 | |
| 25 | Water, wastewater | Total iron concentration Range (0,020 – 35) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 26 | Water, wastewater | Dry residue Range (10 – 10000) mg/l |
Gravimetric method | PN-78/C-04541 | |
| 27 | Water, wastewater | Orthophosphate concentration Range (0,30 – 92) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 | |
| 28 | Water, wastewater | Sulfate concentration Range (20 – 500) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 29 | Water, wastewater | Chemical oxygen demand COD-Cr Range (6 – 50000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 30 | Water, wastewater | Kjeldahl nitrogen concentration Range (1,5 – 300) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 31 | Water, wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 32 | Wastewater | Total phosphorus concentration Range (0,60 – 240) mg/l |
Spectrophotometric method | PBL-34 issue 04 of 24 May 2019 | based on Merck test No. 14729 | |
| 33 | Wastewater | Total nitrogen concentration Range (10 – 300) mg/l |
Spectrophotometric method | PBL-38 issue 01 of 20 January 2025 | based on Merck test No. 14763 | |
| 34 | Wastewater | Ammonium nitrogen concentration Range (10 – 200) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 35 | Sewage sludge | Sampling for chemical, physical, microbiological and biological testing | PN-EN ISO 5667-13:2011 excluding cl. 6.3.4, 6.3.5 and 6.3.7 | ||
| 36 | Sewage sludge | Dry residue Range (0,5 – 32,3) % |
Gravimetric method | PN-EN 12880:2004 | |
| 37 | Sewage sludge | Loss on ignition Range (18,0 – 80,0) % |
Gravimetric method | PN-EN 12879:2004 | |
| 38 | Sewage sludge | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN 12176:2004 | |
| 39 | Water intended for human consumption | Sampling for chemical and physical testing (including sensory testing) Temperature Range (3,0 – 50) °C Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
PN-ISO 5667-5:2017-10 excluding cl. 6.5 | PN-77/C-04584 | ||
| 40 | Water intended for human consumption | Sampling for microbiological testing Temperature Range (3,0 – 50) °C Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
PN-EN ISO 19458:2007 excluding cl. 4.4.3, 4.4.4, 4.4.5 and 4.4.6 | PN-77/C-04584 | ||
| 41 | Water intended for human consumption | Total content of calcium and magnesium (total hardness) Range (50 – 1000) mg/l CaCO3 Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Titrimetric method | PN-ISO 6059:1999 | |
| 42 | Water intended for human consumption | Permanganate index Range (1,0 – 12) mg/l O2 Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 43 | Water intended for human consumption | Chloride concentration Range (5,0 – 250) mg/l Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Titrimetric method | PN-ISO 9297:1994 | |
| 44 | Water intended for human consumption | pH Range 2,0 – 12,0 Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 45 | Water intended for human consumption | Turbidity Range (0,20 – 15) NTU Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 46 | Water intended for human consumption | Electrical conductivity Range (100 – 2500) μS/cm Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Conductometric method | PN-EN 27888:1999 | |
| 47 | Water intended for human consumption | Colour Range (5 – 110) mg/l Pt Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Spectrophotometric method | PN-EN ISO 7887:2012 Method C | |
| 48 | Water intended for human consumption | Iron concentration Range (0,020 – 10) mg/l Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 49 | Water intended for human consumption | Manganese concentration Range (0,015 – 1,50) mg/l Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Spectrophotometric method | PN-92/C-04590/03 | |
| 50 | Water intended for human consumption | Free chlorine concentrations Range (0,02 – 2,0) mg/l Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Spectrophotometric method | PBL-30 issue 03 of 24 May 2019 | based on Hach Lange test No. 21055-60 | |
| 51 | Water intended for human consumption | Ammonium ion concentration Range (0,064 – 4,50) mg/l Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 52 | Water intended for human consumption | Nitrite concentration Range (0,026 – 1,30) mg/l Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Spectrophotometric method | PN-EN 26777:1999 | |
| 53 | Water intended for human consumption | Nitrate concentration Range (0,44 – 50) mg/l Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Spectrophotometric method | PN-82/C-04576.08 | |
| 54 | Water intended for human consumption | Sulfate concentration Range (20 – 250) mg/l Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Gravimetric method | PN-ISO 9280:2002 | |
| 55 | Water intended for human consumption | Escherichia coli count Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 56 | Water intended for human consumption | Coliform bacteria count Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 57 | Water intended for human consumption | Intestinal enterococci count Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 58 | Water intended for human consumption | Total microorganism count at a temperature of 220C Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 59 | Water intended for human consumption | Odour threshold number TON Range 1 Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Simplified method, paired, non-forced choice | PN-EN 1622:2006 | |
| 60 | Water intended for human consumption | Taste threshold number TFN Range 1 Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the legal acts implementing the Act of 7 June 2001 on collective water supply and collective sewage disposal. |
Simplified method, paired, non-forced choice | PN-EN 1622:2006 | |
Reference standards (46)
PBL-30 issue 03 of 24 May 2019
PBL-34 issue 04 of 24 May 2019
PBL-38 issue 01 of 20 January 2025
PN-73/C-04576/14
PN-77/C-04584
PN-78/C-04541
PN-82/C-04576.08
PN-86/C-04573/01
PN-92/C-04590/03
PN-EN 12176:2004
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 excluding cl. 4.4.3, 4.4.4, 4.4.5 and 4.4.6
PN-EN ISO 5667-13:2011 excluding cl. 6.3.4, 6.3.5 and 6.3.7
PN-EN ISO 5667-6:2016-12 excluding cl. 7.2, 7.5, 7.6, 8.2, 9.3 and 9.4
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Method C
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-4:2017-10 excluding cl. 13, 14, 15 and 16
PN-ISO 5667-5:2017-10 excluding cl. 6.5
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
based on Hach Lange test No. 21055-60
based on Merck test No. 14729
based on Merck test No. 14763