🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL

PCA AB 984 • Września, Poland • 56 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 984 (Września, Poland). Its accreditation scope covers 56 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, wastewater, Water, Water intended for human consumption, Wastewater. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 984
  • Methods in scope: 56
  • Types of test objects: 6
  • Techniques used: 12
  • City: Września, Poland
Accreditation number
AB 984
Accreditation body
PCA
Address
ul. Miłosławska 8, 62-300 Września, LABORATORIUM ANALIZ WODY I ŚCIEKÓW, ul. Sikorskiego 42
City
Września, Poland

What this laboratory tests (6)

Analytical techniques used (12)

Accreditation scope — test methods (56)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing (including sensory) Temperature of the collected water sample
Range (3,0 – 50) °C
PN-ISO 5667-5:2017-10 z wył. pkt. 6.5 | PN-77/C-04584 | PN-ISO 5667-5:2017-10
2 Surface water Sampling for chemical and physical testing Temperature of the water sample taken
Range (3,0 – 50) °C
PN-ISO 5667-4:2017-10 z wył. pkt. 13, 14, 15 i 16 | PN-77/C-04584
3 Surface water Temperature of the collected water sample
Range (3,0 – 50) °C
PN-ISO 5667-4:2017-10 z wył. pkt. 13, 14, 15 i 16 | PN-77/C-04584
4 Surface water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.5, 7.6, 8.2, 9.3 i 9.4
5 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (3,0 – 50) °C Sampling for chemical and physical testing
Manual and automatic method; Manual and automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584 | PN-ISO 5667-10:2021-11
6 Wastewater Temperature of the collected wastewater sample PN-ISO 5667-10:2021-11 | PN-77/C-04584 | PN-ISO 5667-10:2021-11
7 Water Total content of calcium and magnesium (total hardness)
Range (10 – 1000) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
8 Water Permanganate index
Range (1,0 – 12) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
9 Water Colour PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012
10 Water
Range (5 – 110) mg/l Pt
Spectrophotometric method Metoda C
11 Water Electrical conductivity
Range (100 – 2500) μS/cm
Conductometric method PN-EN 27888:1999
12 Water Manganese concentration
Range (0,015 – 1,50) mg/l
Spectrophotometric method PN-92/C-04590/03
13 Water Turbidity
Range (0,20 – 15) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
14 Water Dissolved oxygen concentration
Range (0,5 – 15) mg/l Dissolved oxygen concentration Range (0,5 – 15) mg/l
Electrochemical method PN-EN ISO 5814:2013-04
15 Water Free chlorine concentrations PBL-30
16 Water
Range (0,02 – 2,0) mg/l
wydanie nr 03 z dnia 24 maja 2019 r.
17 Water na podstawie testu Hach Lange
18 Water Spectrophotometric method nr 21055-60
19 Water Total alkalinity
Range (0,40 – 20) mmol/l
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
20 Water, wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
21 Water, wastewater Total suspended solids (TSS)
Range (5,0 – 5000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
22 Water, wastewater Chloride concentration
Range (5,0 – 5000) mg/l
Titrimetric method PN-ISO 9297:1994
23 Water, wastewater Ammonium nitrogen concentration
Range (0,05 – 10) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
24 Water, wastewater Nitrite nitrogen concentration
Range (0,008 – 10) mg/l
Spectrophotometric method PN-EN 26777:1999
25 Water, wastewater Nitrate nitrogen concentration
Range (0,10 – 40) mg/l Nitrate nitrogen concentration Range (0,10 – 40) mg/l
Spectrophotometric method PN-82/C-04576.08
26 Water, wastewater Total phosphorus concentration PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 | PN-EN ISO 6878:2006+Ap1:2010
27 Water, wastewater
Range (0,10 – 60) mg/l
Spectrophotometric method +Ap2:2010
28 Water, wastewater Biochemical oxygen demand
BOD5 Range (3 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
29 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
30 Water, wastewater Anionic detergent concentration
Range (0,10 – 45) mg/l
Spectrophotometric method PN-EN 903:2002
31 Water, wastewater Concentration of substances extractable with petroleum ether
Range (20 – 1000) mg/l
Gravimetric method PN-86/C-04573/01
32 Water, wastewater Total iron concentration
Range (0,020 – 35) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
33 Water, wastewater Dry residue
Range (10 – 10000) mg/l
Gravimetric method PN-78/C-04541
34 Water, wastewater Orthophosphate concentration
Range (0,30 – 92) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 | PN-EN ISO 6878:2006+Ap1:2010
35 Water, wastewater Sulfate concentration
Range (20 – 500) mg/l
Gravimetric method PN-ISO 9280:2002
36 Water, wastewater Chemical oxygen demand
COD-Cr Range (6 – 50000) mg/l O2 Chemical oxygen demand COD-Cr Range (6 – 50000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
37 Water, wastewater Kjeldahl nitrogen concentration
Range (1,5 – 300) mg/l
Titrimetric method PN-EN 25663:2001
38 Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14
39 Wastewater Total phosphorus concentration
Range (0,60 – 240) mg/l Total phosphorus concentration
Spectrophotometric method PBL-34 wydanie nr 04 z dnia 24 maja 2019 r. | na podstawie testu Merck nr 14729 PBL-34
40 Wastewater
Range (0,60 – 240) mg/l
wydanie nr 04 z dnia 24 maja 2019 r.
41 Wastewater Total nitrogen concentration
Range (10 – 300) mg/l
Spectrophotometric method PBL-38 wydanie nr 01 z dnia 20 stycznia 2025 r. | na podstawie testu Merck nr 14763 | na podstawie testu Merck nr 14763
42 Wastewater Ammonium nitrogen concentration
Range (10 – 200) mg/l Ammonium nitrogen concentration Range (10 – 200) mg/l
Titrimetric method PN-ISO 5664:2002
43 Sewage sludge Sampling for chemical, physical, microbiological and biological testing PN-EN ISO 5667-13:2011 z wył. pkt. 6.3.4, 6.3.5 i 6.3.7
44 Sewage sludge Dry residue
Range (0,5 – 32,3) %
Gravimetric method; Gravimetric method PN-EN 12880:2004
45 Sewage sludge Loss on ignition
Range (18,0 – 80,0) %
Gravimetric method; Gravimetric method PN-EN 12879:2004
46 Sewage sludge pH
Range 2,0 – 12,0
Potentiometric method PN-EN 12176:2004
47 Water intended for human consumption Sampling for testing PN-EN ISO 19458:2007
48 Water intended for human consumption microbiological z wył. pkt. 4.4.3, 4.4.4, 4.4.5 i 4.4.6
49 Water intended for human consumption Escherichia coli count PN-EN ISO 9308-1:2014-12
50 Water intended for human consumption Membrane filtration method +A1:2017-04
51 Water intended for human consumption Coliform bacteria count PN-EN ISO 9308-1:2014-12
52 Water intended for human consumption Membrane filtration method +A1:2017-04
53 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
54 Water intended for human consumption Total microorganism count at a temperature of 22°C Plate method (pour plate) PN-EN ISO 6222:2004
55 Water intended for human consumption Odour threshold number TON
Range 1
Simplified method, paired, non-forced choice PN-EN 1622:2006
56 Water intended for human consumption Taste threshold number TFN
Range 1
Simplified method, paired, non-forced choice PN-EN 1622:2006

Reference standards (56)

+A1:2017-04
+Ap2:2010
Metoda C
PBL-30
PBL-34 wydanie nr 04 z dnia 24 maja 2019 r.
PBL-38 wydanie nr 01 z dnia 20 stycznia 2025 r.
PN-73/C-04576/14
PN-77/C-04584
PN-78/C-04541
PN-82/C-04576.08
PN-86/C-04573/01
PN-92/C-04590/03
PN-EN 12176:2004
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5667-13:2011 z wył. pkt. 6.3.4, 6.3.5 i 6.3.7
PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.5, 7.6, 8.2, 9.3 i 9.4
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+Ap1:2010
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012
PN-EN ISO 7887:2012 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-4:2017-10 z wył. pkt. 13, 14, 15 i 16
PN-ISO 5667-5:2017-10
PN-ISO 5667-5:2017-10 z wył. pkt. 6.5
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
na podstawie testu Hach Lange
na podstawie testu Merck nr 14729 PBL-34
na podstawie testu Merck nr 14763
nr 21055-60
wydanie nr 03 z dnia 24 maja 2019 r.
wydanie nr 04 z dnia 24 maja 2019 r.
z wył. pkt. 4.4.3, 4.4.4, 4.4.5 i 4.4.6