🇵🇱 KWANT-LAB PL

PCA AB 982 • Poznań, Poland • 20 methods

Electronics & EMCEnvironmentAutomotive

KWANT-LAB is a laboratory accredited by PCA under number AB 982 (Poznań, Poland). Its accreditation scope covers 20 test methods in the following areas: Electronics & EMC, Environment, Automotive. Test objects include: Workplace environment − electromagnetic field from equipment used i…, Workplace environment − electromagnetic field originating from indu…, Environment - electromagnetic field in the vicinity of electric pow…, Workplace environment - electromagnetic field from power systems an…. Most frequently used techniques: Direct measurement method.

At a glance

  • Accreditation number: PCA AB 982
  • Methods in scope: 20
  • Types of test objects: 6
  • Techniques used: 1
  • City: Poznań, Poland
Accreditation number
AB 982
Accreditation body
PCA
Address
Tomasz Kaźmierowski, ul. Pokrzywno 4, 61-315 Poznań
City
Poznań, Poland

What this laboratory tests (6)

Analytical techniques used (1)

Accreditation scope — test methods (20)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry Electric field strength:
in the frequency range from 10 Hz do 1 kHz Range 1 V/m – 50 kV/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150
2 Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry Magnetic flux density:
in the frequency range from 10 Hz do 1 kHz Range 0,023 μT – 19 mT
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150
3 Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry Magnetic field strength:
in the frequency range from 10 Hz do 1 kHz (calculated)
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150
4 Workplace environment - electromagnetic field in the workspace originating from magnetotherapy or magnetostimulation devices Electric field strength:
in the frequency range from 10 Hz do 1 kHz Range 1 V/m – 50 kV/m from 1 kHz do 100 kHz Range 1 V/m – 20 kV/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
5 Workplace environment - electromagnetic field in the workspace originating from magnetotherapy or magnetostimulation devices Magnetic flux density:
in the frequency range from 10 Hz do 1 kHz Range 0,023 μT – 19 mT from 1 kHz do 100 kHz Range 0,023 μT – 2 mT
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
6 Workplace environment - electromagnetic field in the workspace originating from magnetotherapy or magnetostimulation devices Magnetic field strength:
in the frequency range from 10 Hz do 100 kHz (calculated)
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
7 Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - special equipment: magnetic separators and industrial static field devices Electric field strength:
in the frequency range from 10 Hz do 1 kHz Range 1 V/m − 50 kV/m in the frequency range from 1 kHz do 100 kHz Range 1 V/m − 20 kV/m in the frequency range from 100 kHz do 500 kHz Range 1 V/m − 2 kV/m in the frequency range from 100 kHz do 3 GHz Range (0,84 – 970) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB 17-1 wydanie 3 z 15.05.2025 r.
8 Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - special equipment: magnetic separators and industrial static field devices Magnetic flux density:
in the frequency range 0 Hz Range (0,125 – 1000) mT from 10 Hz do 600 kHz Range 0,023 μT – 19 mT
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB 17-1 wydanie 3 z 15.05.2025 r.
9 Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - special equipment: magnetic separators and industrial static field devices Magnetic field strength:
in the frequency range from 0,3 MHz do 30 MHz Range (0,01 – 16,0) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB 17-1 wydanie 3 z 15.05.2025 r.
10 Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - special equipment: magnetic separators and industrial static field devices Magnetic field strength:
in the frequency range 0 Hz in the frequency range from 10 Hz do 600 kHz in the frequency range from 800 MHz do 3 GHz (calculated)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB 17-1 wydanie 3 z 15.05.2025 r.
11 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones Electric field strength:
in the frequency range from 100 kHz do 3 GHz Range (0,84 – 970) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB 17-1 wydanie 3 z 15.05.2025 r.
12 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones Magnetic field strength:
in the frequency range from 0,3 MHz do 30 MHz Range (0,01 – 16,0) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB 17-1 wydanie 3 z 15.05.2025 r.
13 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones Magnetic field strength:
in the frequency range from 30 MHz do 3 GHz (calculated)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB 17-1 wydanie 3 z 15.05.2025 r.
14 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Electric field strength:
in the frequency range from 10 Hz do 1 kHz Range 1 V/m − 50 kV/m in the frequency range from 1 kHz do 100 kHz Range 1 V/m − 20 kV/m in the frequency range from 100 kHz do 500 kHz Range 1 V/m − 2 kV/m in the frequency range from 100 kHz do 3 GHz Range (0,84 – 970) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB 17-1 wydanie 3 z 15.05.2025 r.
15 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Magnetic flux density:
in the frequency range 0 Hz Range (0,125 – 1000) mT in the frequency range from 10 Hz do 600 kHz Range 0,023 μT – 19 mT
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB 17-1 wydanie 3 z 15.05.2025 r.
16 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Magnetic field strength:
in the frequency range from 0,3 MHz do 30 MHz Range (0,01 – 16,0) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB 17-1 wydanie 3 z 15.05.2025 r.
17 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Magnetic field strength:
in the frequency range from 10 Hz do 600 kHz in the frequency range from 800 MHz do 3 GHz (calculated)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB 17-1 wydanie 3 z 15.05.2025 r.
18 Environment - electromagnetic field in the vicinity of electric power substations and power lines Electric field strength:
in the frequency range from 10 Hz do 1 kHz Range 1 V/m – 50 kV/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
19 Environment - electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density:
in the frequency range from 10 Hz do 1 kHz Range 0,023 μT – 19 mT
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
20 Environment - electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength:
in the frequency range from 10 Hz do 1 kHz (calculated)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)

Reference standards (5)

PB 17-1 wydanie 3 z 15.05.2025 r.
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)