🇵🇱 STORA ENSO NAREW Sp. z o.o. PL

PCA AB 968 • Ostrołęka, Poland • 8 methods

Environment

STORA ENSO NAREW Sp. z o.o. is a laboratory accredited by PCA under number AB 968 (Ostrołęka, Poland). Its accreditation scope covers 8 test methods in the following areas: Environment. Test objects include: Workplace environment – air, Workplace environment – hot microclimate, Workplace environment – noise. Most frequently used techniques: Direct measurement method, Gravimetric method, Personal dosimetry method.

At a glance

  • Accreditation number: PCA AB 968
  • Methods in scope: 8
  • Types of test objects: 3
  • Techniques used: 3
  • City: Ostrołęka, Poland
Accreditation number
AB 968
Accreditation body
PCA
Address
LABORATORIUM, PRACOWNIA BADAŃ ŚRODOWISKA PRACY I PALIW, Aleja Wojska Polskiego 21, 07-401 Ostrołęka
City
Ostrołęka, Poland

What this laboratory tests (3)

Analytical techniques used (3)

Accreditation scope — test methods (8)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment – air Sampling for the assessment of occupational exposure to:
dust agents – inhalable fraction – respirable fraction inorganic substances – respirable fraction
Personal dosimetry method PN-Z-04008-7:2002
2 Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002
3 Workplace environment – air Concentration of harmful dust agents - inhalable fraction:
Wood dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,15 – 20,42) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
4 Workplace environment – air Concentration of harmful dust agents - respirable fraction:
Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,13 – 18,56) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
5 Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (28 – 125) dB C-weighted peak sound pressure level Range (55 – 136) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 - punkt 10 i 11
6 Workplace environment – noise Noise exposure level referred to:
an 8-hour daily working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 - punkt 10 i 11
7 Workplace environment – hot microclimate Air temperature
Range (10 – 50) °C Natural wet bulb temperature Range (5 – 40) °C Black globe temperature Range (20 – 50) °C
Direct measurement method PN-EN ISO 7243:2018-01
8 Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01

Reference standards (8)

PN-EN ISO 7243:2018-01
PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 - punkt 10 i 11
PN-N-01307:1994
PN-Z-04008-7:2002
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08