🇵🇱 GEOTEKO PL

PCA AB 962 • Warszawa, Poland • 17 methods

EnvironmentMaterials & polymersWater & wastewater

GEOTEKO is a laboratory accredited by PCA under number AB 962 (Warszawa, Poland). Its accreditation scope covers 17 test methods in the following areas: Environment, Materials & polymers, Water & wastewater. Test objects include: Soil. Most frequently used techniques: Cone method (single-point and multi-point), Direct measurement method.

At a glance

  • Accreditation number: PCA AB 962
  • Methods in scope: 17
  • Types of test objects: 1
  • Techniques used: 2
  • City: Warszawa, Poland
Accreditation number
AB 962
Accreditation body
PCA
Address
PROJEKTY I KONSULTACJE GEOTECHNICZNE Sp. z o.o., LABORATORIUM GEOTECHNICZNE, im. prof. dr hab. inż. WOJCIECHA WOLSKIEGO, ul. Wałbrzyska 14/16, 02-739 Warszawa
City
Warszawa, Poland

What this laboratory tests (1)

Analytical techniques used (2)

Accreditation scope — test methods (17)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Soil Macroscopic analysis, Macroscopic description PN-88/B-04481
2 Soil Macroscopic analysis, Macroscopic description PN-EN ISO 14688-1:2018-05
3 Soil Water concent PN-EN ISO 17892-1:2015-02
4 Soil Sieve analysis PN-EN ISO 17892-4:2017-01
5 Soil Hydrometer analysis PN-EN ISO 17892-4:2017-01
6 Soil Plastic limit, Plastic limit PN-EN ISO 17892-12:2018-08
7 Soil Liquid limit
Liquid limit
Cone method (single-point and multi-point) PN-EN ISO 17892-12:2018-08
8 Soil Maximum and minimum bulk density of the soil skeleton PN-88/B-04481
9 Soil Bulk density of fine-grained soils
Bulk density
Direct measurement method PN-EN ISO 17892-2:2015-02
10 Soil Particle density PN-EN ISO 17892-3:2016-03
11 Soil Oedometer test of soils
Load range (0 - 6400) kPa
PN-EN ISO 17892-5:2017-06
12 Soil Testing of soils in a triaxial compression apparatus after water saturation
Pressure range in the chamber (0 - 3500) kPa
PN-EN ISO 17892-9:2018-05
13 Soil Testing of soils in a triaxial compression apparatus without water saturation and without consolidation
Pressure range in the chamber (0 - 3500) kPa
PN-EN ISO 17892-8:2018-05
14 Soil Uniaxial compression, Compressive force (0,5 - 25) kN PN-EN ISO 17892-7:2018-05
15 Soil Direct shear apparatus test – shear box apparatus PN-EN ISO 17892-10:2019-01
16 Soil Loss of mass on ignition PN-EN 17685-1:2023-08
17 Soil Swelling pressure PKN-CEN ISO/TS 17892-5:2009 Scope of accreditation No. AB 962

Reference standards (14)

PKN-CEN ISO/TS 17892-5:2009 Scope of accreditation No. AB 962
PN-88/B-04481
PN-EN 17685-1:2023-08
PN-EN ISO 14688-1:2018-05
PN-EN ISO 17892-10:2019-01
PN-EN ISO 17892-12:2018-08
PN-EN ISO 17892-1:2015-02
PN-EN ISO 17892-2:2015-02
PN-EN ISO 17892-3:2016-03
PN-EN ISO 17892-4:2017-01
PN-EN ISO 17892-5:2017-06
PN-EN ISO 17892-7:2018-05
PN-EN ISO 17892-8:2018-05
PN-EN ISO 17892-9:2018-05