🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL

PCA AB 901 • Szczecinek, Poland • 39 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 901 (Szczecinek, Poland). Its accreditation scope covers 39 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Swimming pool water, Water, Wastewater, Swimming pool water, Water, Water intended for human consumption, Wastewater. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 901
  • Methods in scope: 39
  • Types of test objects: 14
  • Techniques used: 15
  • City: Szczecinek, Poland
Accreditation number
AB 901
Accreditation body
PCA
Address
ul. Bugno 2, 78-400 Szczecinek, LABORATORIUM BADAŃ WODY I ŚCIEKÓW, ul. Rybacka 5
City
Szczecinek, Poland

What this laboratory tests (14)

Analytical techniques used (15)

Laboratory locations

Accreditation scope — test methods (39)

No. Test object Methodology / Parameters Technique Reference document
Water and Wastewater Testing Laboratory
1 Water Sampling for chemical and physical testing Temperature of the sample taken
Range (4,0 – 40,0) oC
PN-ISO 5667-4:2003 | PN-EN ISO 5667-6:2016-12 | PN-77/C-04584
2 Water intended for human consumption Sampling for chemical and physical testing Temperature of the sample taken
Range (4,0 – 80,0) oC
PN-ISO 5667-5:2017-10 | PN-77/C-04584
3 Swimming pool water Sampling for chemical and physical testing
Temperature of the collected sample (Range (4,0 – 40,0)°C
PO-08/I-03 wyd.1 z 12.01.2022 r. | PN-77/C-04584
4 Wastewater, Rainwater and snowmelt water Sampling for chemical and physical testing
Temperature of the collected sample Range (4,0 – 40,0) oC
Manual method PN-ISO 5667-10:2021-11 | PN-77/C-04584
5 Wastewater Sampling for chemical and physical testing
Temperature of the collected sample Range (4,0 – 40,0) oC
Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
6 Water, Wastewater Biochemical oxygen demand
BOD5 Range (1 – 6000) mg/l O2
Titrimetric method; Optical method PN-EN ISO 5815-1:2019-12
7 Water, Wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6,0) mg/l O2
Titrimetric method PN-EN 1899-2:2002
8 Water, Wastewater Chemical oxygen demand - SP-COD
Range (5,00 – 4000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005 z wyłączeniem pkt. 10.3
9 Water, Wastewater Total nitrogen concentration
Range (3,00 – 400) mg/l
Spectrophotometric method PB 3.9 wydanie 5 z dnia 16.12.2019 wg testów kuwetowych Hach-Lange LCK 138, LCK 238, LCK 338
10 Water, Wastewater Total phosphorus concentration
Range (0,30 – 400) mg/l
Spectrophotometric method PB 3.10 wydanie 5 z dnia 16.12.2019 wg testów kuwetowych Hach-Lange LCK 349, LCK 350
11 Water, Wastewater Total phosphorus concentration
Range (0,30 – 30,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 pkt 7
12 Wastewater Settleable solids
Range (0,5 – 100) ml/l
Volumetric method PN-C-04559-03:1972
13 Wastewater Content of substances extractable with petroleum ether
Range (5 – 1000) mg/l
Gravimetric method PN-86/C-04573/01
14 Water Dissolved oxygen concentration
Range (0,2 – 13) mg/l O2
Optical method PB 3.15 wyd. 5 z dn. 12.12.2024r.
15 Water, Wastewater, Rainwater and snowmelt water Total suspended solids (TSS)
Range (5,0 – 3000) mg/l
Gravimetric method PN-EN 872:2007+ Ap1:2007
16 Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water Electrical conductivity
Range (150 – 12850) μS/cm
Conductometric method PN-EN 27888:1999
17 Water, Water intended for human consumption, Wastewater Ammonium ion concentration
Range (0,15 – 160) mg/l
Spectrophotometric method PB 3.13 wydanie 4 z dnia 16.12.2019 wg testów kuwetowych Hach-Lange LCK 304, LCK 303, LCK 302
18 Water, Water intended for human consumption, Wastewater Chloride concentration
Range (5 – 2000) mg/l
Titrimetric method PN-ISO 9297:1994
19 Water, Water intended for human consumption, Wastewater Nitrate concentration
Range (1,5 – 150) mg/l
Spectrophotometric method PB 3.18 wydanie 3 z dnia 16.12.2019 wg testów kuwetowych Hach-Lange LCK 339, LCK 340
20 Water, Water intended for human consumption, Wastewater Total iron concentration
Range (0,060 – 20,0) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
21 Water, Water intended for human consumption Manganese concentration
Range (0,030 – 0,250) mg/l
Spectrophotometric method PN-92/C-04590/02
22 Water, Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (10 – 500) mg /l CaCO3
Titrimetric method PN-ISO 6059:1999
23 Water, Water intended for human consumption, Swimming pool water Turbidity
Range (0,20 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
24 Water, Water intended for human consumption, Swimming pool water Permanganate index
Range (0,5 – 10) mg/l
Titrimetric method PN-EN ISO 8467:2001
25 Water, Water intended for human consumption, Swimming pool water Free chlorine concentration
Range (0,20 – 3,0) mg/l
Colorimetric method PB 3.21 wydanie 3 z dnia 16.12.2019
26 Swimming pool water Total chlorine concentration, Range; (0,20 – 3,0) mg/l Colorimetric method PB 3.21 wydanie 3 z dnia 16.12.2019
27 Swimming pool water Combined chlorine concentration (calculated) PB 3.21 wydanie 3 z dnia 16.12.2019
28 Water, Water intended for human consumption, Swimming pool water, Wastewater pH
Range (4,0 – 10,0)
Potentiometric method PN-EN ISO 10523:2012
29 Water, Water intended for human consumption, Swimming pool water, Bathing water Sampling for microbiological testing Temperature of the collected sample
Range (4,0 – 40,0) oC
PN-EN ISO 19458:2007 | PN-77/C-04584
30 Water, Water intended for human consumption, Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04
31 Water, Water intended for human consumption, Swimming pool water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04
32 Water, Water intended for human consumption, Swimming pool water Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
33 Water, Water intended for human consumption, Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
34 Water, Water intended for human consumption, Swimming pool water Count of bacteria of the genus Legionella, Matrix B, Procedure 7, Medium C-GVPC Membrane filtration method PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12
35 Water, Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
36 Water, Water intended for human consumption, Swimming pool water, Bathing water Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
37 Water, Water intended for human consumption, Swimming pool water, Bathing water Most probable number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
38 Water, Water intended for human consumption, Bathing water Enterococci (faecal streptococci) count Membrane filtration method PN-EN ISO 7899-2:2004
39 Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000 zał. A

Reference standards (37)

PB 3.10 wydanie 5 z dnia 16.12.2019 wg testów kuwetowych Hach-Lange LCK 349, LCK 350
PB 3.13 wydanie 4 z dnia 16.12.2019 wg testów kuwetowych Hach-Lange LCK 304, LCK 303, LCK 302
PB 3.15 wyd. 5 z dn. 12.12.2024r.
PB 3.18 wydanie 3 z dnia 16.12.2019 wg testów kuwetowych Hach-Lange LCK 339, LCK 340
PB 3.21 wydanie 3 z dnia 16.12.2019
PB 3.9 wydanie 5 z dnia 16.12.2019 wg testów kuwetowych Hach-Lange LCK 138, LCK 238, LCK 338
PN-77/C-04584
PN-86/C-04573/01
PN-92/C-04590/02
PN-C-04559-03:1972
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007+ Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08
PN-EN ISO 11731:2017-08/Ap1:2019-12
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 5667-6:2016-12
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 pkt 7
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12/A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005 z wyłączeniem pkt. 10.3
PN-ISO 5667-10:2021-11
PN-ISO 5667-4:2003
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 9297:1994
PN-Z-11001-3:2000 zał. A
PO-08/I-03 wyd.1 z 12.01.2022 r.