🇵🇱 MILAB Czesław Misiun PL
EnvironmentElectronics & EMC
MILAB Czesław Misiun is a laboratory accredited by PCA under number AB 900 (Koszalin, Poland). Its accreditation scope covers 24 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Workplace environment − air, Workplace environment - emergency lighting, General environment − noise from machines, equipment, installations…, Workplace environment - electromagnetic field from power systems an…. Most frequently used techniques: Direct measurement method, Gravimetric method, Direct measurement method (simplified).
At a glance
- Accreditation number: PCA AB 900
- Methods in scope: 24
- Types of test objects: 11
- Techniques used: 4
- City: Koszalin, Poland
- Accreditation number
- AB 900
- Accreditation body
- PCA
- Address
- ul. Westerplatte 23, 75-642 Koszalin
- City
- Koszalin, Poland
What this laboratory tests (11)
- Workplace environment − air — 4 methods
- Workplace environment - emergency lighting — 3 methods
- General environment − noise from machines, equipment, installations, industrial plants — 2 methods
- Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry — 2 methods
- Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units — 2 methods
- Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial furnaces, heaters, - electrical discharge machines — 2 methods
- Workplace environment − hand-arm vibration — 2 methods
- Workplace environment − indoor electric lighting — 2 methods
- Workplace environment − noise — 2 methods
- Workplace environment − whole-body vibration — 2 methods
- Workplace environment - electromagnetic field in the workspace from magnetotherapy devices — 1 method
Analytical techniques used (4)
- Direct measurement method — 13 methods
- Gravimetric method — 2 methods
- Direct measurement method (simplified) — 1 method
- Personal dosimetry method — 1 method
Accreditation scope — test methods (24)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratorium ul. Westerplatte 23, 75-642 Koszalin | |||||
| 1 | Workplace environment − noise | Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C Poziom ciśnienia akustycznego w pasmach oktawowych (63 - 8000) Hz A-weighted equivalent sound pressure level (35,0 – 135,0) dB Maximum A-weighted sound pressure level (35,0 – 135,0) dB C-weighted peak sound pressure level (35,0 – 137,0) dB Poziom ciśnienia akustycznego w pasmach oktawowych (63 - 8000) Hz (25,0 – 135,0) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 - p. 10 i strategię 3 - p. 11 | |
| 2 | Workplace environment − noise | Noise exposure level normalised to: − an 8-hour working day − an average weekly working time (calculated) | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 - p. 10 i strategię 3 - p. 11 | ||
| 3 | General environment − noise from machines, equipment, installations, industrial plants | A-weighted equivalent sound pressure level Range (24,0 – 90,0) dB |
Direct measurement method | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem pkt. F | |
| 4 | General environment − noise from machines, equipment, installations, industrial plants | A-weighted equivalent sound level for reference time T (calculated) | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem pkt. F | ||
| 5 | Workplace environment − air | Air sampling for the assessment of occupational exposure to: − czynniki pyłowe - frakcja wdychalna - frakcja respirabilna − substancje organiczne, w tym - frakcja wdychalna − substancje nieorganiczne - frakcja respirabilna − metale i ich związki, w tym - frakcja wdychalna - frakcja respirabilna |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 6 | Workplace environment − air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 7 | Workplace environment − air | Concentration of harmful dust agents – inhalable fraction: Apatites and phosphorites Petroleum bitumen Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Carbon black Calcium sulfate (VI) (gypsum) Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,10 – 17,0) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 8 | Workplace environment − air | Concentration of harmful dust agents – respirable fraction: Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,10 – 15,0) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 9 | Workplace environment − indoor electric lighting | Illuminance Range (0,5 – 10000) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 10 | Workplace environment − indoor electric lighting | Illuminance uniformity (calculated) | PN-83/E-04040.03 | ||
| 11 | Workplace environment - emergency lighting | Illuminance Range (0,5 – 100) lx |
Direct measurement method | PN-EN 1838:2013-11 pkt. 4.2.1, pkt. 4.2.2, pkt. 4.2.5, pkt. 4.2.6 | |
| 12 | Workplace environment - emergency lighting | Ratio of minimum to maximum illuminance (calculated) | PN-EN 1838:2013-11 pkt. 4.2.1, pkt. 4.2.2, pkt. 4.2.5, pkt. 4.2.6 | ||
| 13 | Workplace environment - emergency lighting | Closing time Range (1 – 80) s |
Direct measurement method | PN-EN 1838:2013-11 pkt. 4.2.1, pkt. 4.2.2, pkt. 4.2.5, pkt. 4.2.6 | |
| 14 | Workplace environment − hand-arm vibration | Frequency-corrected effective vibration acceleration Range (0,5 – 30) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 15 | Workplace environment − hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 16 | Workplace environment − whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,07 – 35) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 17 | Workplace environment − whole-body vibration | Daily exposure expressed as the energy-equivalent for 8 hours of the r.m.s., frequency-weighted vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz)., Exposure lasting 30 min. and less expressed as the r.m.s., frequency-weighted vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 18 | Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial furnaces, heaters, - electrical discharge machines | Electric field strength: w zakresie częstotliwości od 10 Hz do 400 kHz (1 – 50 000) V/m w zakresie częstotliwości od 0,1 MHz do 300 MHz (1,4 − 1100) V/m Regulated area: Metoda dostosowana do obszaru regulowanego |
Direct measurement method | PN-T-06580-3:2002 | IR 18 wydanie nr 1 z 22.04.2026 r. | IR 18A wydanie nr 1 z 22.04.2026 r. | IR 18D wydanie nr 1 z 22.04.2026 r. | IR 18E wydanie nr 1 z 22.04.2026 r. | |
| 19 | Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial furnaces, heaters, - electrical discharge machines | Magnetic field strength: w zakresie częstotliwości od 10 Hz do 400 kHz (0,8 – 15 800) A/m w zakresie częstotliwości od 0,2 MHz do 2 MHz (0,03 – 14,2) A/m w zakresie częstotliwości od 10 MHz do 40 MHz (0,012 − 5) A/m Regulated area: Metoda dostosowana do obszaru regulowanego |
Direct measurement method | PN-T-06580-3:2002 | IR 18 wydanie nr 1 z 22.04.2026 r. | IR 18A wydanie nr 1 z 22.04.2026 r. | IR 18D wydanie nr 1 z 22.04.2026 r. | IR 18E wydanie nr 1 z 22.04.2026 r. | |
| 20 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | Electric field strength: w zakresie częstotliwości od 0,1 MHz do 300 MHz (1,4 − 1100) V/m Regulated area: Metoda dostosowana do obszaru regulowanego |
Direct measurement method | PN-T-06580-3:2002 | IR 18 wydanie nr 1 z 22.04.2026 r. | IR 18B wydanie nr 1 z 22.04.2026 r. | IR 18C wydanie nr 1 z 22.04.2026 r. | |
| 21 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | Magnetic field strength: w zakresie częstotliwości od 0,2 MHz do 2 MHz (0,03 – 14,2) A/m w zakresie częstotliwości od 10 MHz do 40 MHz (0,012 − 5) A/m Regulated area: Metoda dostosowana do obszaru regulowanego |
Direct measurement method | PN-T-06580-3:2002 | IR 18 wydanie nr 1 z 22.04.2026 r. | IR 18B wydanie nr 1 z 22.04.2026 r. | IR 18C wydanie nr 1 z 22.04.2026 r. | |
| 22 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Electric field strength: w zakresie częstotliwości od 10 Hz do 400 kHz (1 – 50 000) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150 | |
| 23 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Magnetic field strength: w zakresie częstotliwości od 10 Hz do 400 kHz (0,8 – 15 800) A/m Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150 | |
| 24 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices | Magnetic field strength: w zakresie częstotliwości od 10 Hz do 400 Hz (0,8 – 15 800) A/m Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 poz. 331). |
Direct measurement method (simplified) | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 | |
Reference standards (23)
IR 18 wydanie nr 1 z 22.04.2026 r.
IR 18A wydanie nr 1 z 22.04.2026 r.
IR 18B wydanie nr 1 z 22.04.2026 r.
IR 18C wydanie nr 1 z 22.04.2026 r.
IR 18D wydanie nr 1 z 22.04.2026 r.
IR 18E wydanie nr 1 z 22.04.2026 r.
PN-83/E-04040.03
PN-EN 14253+A1:2011
PN-EN 1838:2013-11 pkt. 4.2.1, pkt. 4.2.2, pkt. 4.2.5, pkt. 4.2.6
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 - p. 10 i strategię 3 - p. 11
PN-N-01307:1994
PN-T-06580-3:2002
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem pkt. F