🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL
Water & wastewaterMicrobiology
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 893 (Olkusz, Poland). Its accreditation scope covers 29 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Titrimetric method.
At a glance
- Accreditation number: PCA AB 893
- Methods in scope: 29
- Types of test objects: 2
- Techniques used: 10
- City: Olkusz, Poland
- Accreditation number
- AB 893
- Accreditation body
- PCA
- Address
- ul. Kluczewska 4, 32-300 Olkusz, LABORATORIUM BADANIA WODY I ŚCIEKÓW, ul. Wspólna 2 C, 32-300 Olkusz
- City
- Olkusz, Poland
What this laboratory tests (2)
- Water, water intended for human consumption — 27 methods
- Water intended for human consumption — 2 methods
Analytical techniques used (10)
- Spectrophotometric method — 10 methods
- Membrane filtration method — 4 methods
- Titrimetric method — 4 methods
- MPN method — 2 methods
- Conductometric method — 1 method
- Ion chromatography with conductometric detection (IC-CD) — 1 method
- Nephelometric method — 1 method
- Plate method (pour plate) — 1 method
- Potentiometric method — 1 method
- Visual method — 1 method
Accreditation scope — test methods (29)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 2 | Water, water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 3 | Water intended for human consumption | Anion concentrations chlorides (5,0 – 250) mg/l nitrates (5,0 – 50) mg/l nitrites (0,025 – 0,50) mg/l sulfates (8,0 – 250) mg/l fluorides (0,05 – 1,50) mg/l phosphates (0,050 – 1,00) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 4 | Water, water intended for human consumption | Electrical conductivity Range (10 − 3900) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 5 | Water, water intended for human consumption | pH Range 2,0 − 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 6 | Water, water intended for human consumption | Colour Range (5 − 50) mg/l Pt |
Visual method | PN-EN ISO 7887:2012 Metoda D | |
| 7 | Water, water intended for human consumption | Turbidity Range (0,10 − 20) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 8 | Water, water intended for human consumption | Total iron concentration Range (0,050 − 2,50) mg/l |
Spectrophotometric method | IP/PB/11 wydanie 6 z dnia 01.07.2021 r. na podstawie metody HACH LANGE nr 8008 | |
| 9 | Water, water intended for human consumption | Manganese concentration Range (0,010 − 0,200) mg/l |
Spectrophotometric method | IP/PB/12 wydanie 6 z dnia 01.07.2021 r. na podstawie metody HACH LANGE nr 8149 | |
| 10 | Water, water intended for human consumption | Nitrate concentration Range (1 − 60) mg/l |
Spectrophotometric method | IP/PB/87 wydanie 4 z dnia 01.07.2021 r. na podstawie testu HACH LANGE nr LCK 339 | |
| 11 | Water, water intended for human consumption | Nitrite concentration Range (0,015 − 1,00) mg/l |
Spectrophotometric method | IP/PB/14 wydanie 6 z dnia 01.07.2021 r. na podstawie metody HACH LANGE nr 8507 | |
| 12 | Water, water intended for human consumption | Ammonium ion concentration Range (0,10 − 1,20) mg/l |
Spectrophotometric method | IP/PB/110 wydanie 1 z dnia 01.07.2025 r. na podstawie metody HACH LANGE nr 8038 | |
| 13 | Water, water intended for human consumption | Calcium concentration Range (2 − 200) mg/l |
Titrimetric method | PN-ISO 6058:1999 | |
| 14 | Water, water intended for human consumption | Magnesium concentration (calculated) | PN-C-04554-4:1999 Załącznik A | ||
| 15 | Water, water intended for human consumption | Total content of calcium and magnesium (total hardness) Range (7 − 900) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 16 | Water, water intended for human consumption | Permanganate index Range (0,5 − 10) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 17 | Water, water intended for human consumption | Orthophosphate concentration Range (0,032 − 0,500) mg/l |
Spectrophotometric method | IP/PB/15 wydanie 6 z dnia 01.07.2021 r. | na podstawie metody HACH LANGE nr 8048 | |
| 18 | Water, water intended for human consumption | Chloride concentration Range (5,00 – 250) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 19 | Water, water intended for human consumption | Sulfate concentration Range (2,0 − 250) mg/l |
Spectrophotometric method | IP/PB/08 wydanie 7 z dnia 01.07.2021 r. | na podstawie metody HACH LANGE nr 8051 | |
| 20 | Water, water intended for human consumption | Cyanide concentration Range (0,010 − 0,100) mg/l |
Spectrophotometric method | IP/PB/18 wydanie 5 z dnia 01.07.2021 r. | na podstawie metody HACH LANGE nr 8027 | |
| 21 | Water, water intended for human consumption | Fluoride concentration Range (0,25 − 2,00) mg/l |
Spectrophotometric method | IP/PB/19 wydanie 5 z dnia 01.07.2021 r. | na podstawie metody HACH LANGE nr 8029 | |
| 22 | Water, water intended for human consumption | Free chlorine concentration Range (0,10 − 1,0) mg/l |
Spectrophotometric method | PN-EN ISO 7393-2:2018-04 | |
| 23 | Water, water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 24 | Water, water intended for human consumption | Total count of microorganisms at 22 °C and at 36 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 25 | Water, water intended for human consumption | Most probable number of coliform bacteria and Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 26 | Water, water intended for human consumption | Most probable number of intestinal enterococci | MPN method | IP/PB/107 wydanie 1 z dnia 30.09.2020 r. (Test Enterolert-DW) | |
| 27 | Water, water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 28 | Water, water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 29 | Water, water intended for human consumption | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
Reference standards (32)
IP/PB/08 wydanie 7 z dnia 01.07.2021 r.
IP/PB/107 wydanie 1 z dnia 30.09.2020 r. (Test Enterolert-DW)
IP/PB/11 wydanie 6 z dnia 01.07.2021 r. na podstawie metody HACH LANGE nr 8008
IP/PB/110 wydanie 1 z dnia 01.07.2025 r. na podstawie metody HACH LANGE nr 8038
IP/PB/12 wydanie 6 z dnia 01.07.2021 r. na podstawie metody HACH LANGE nr 8149
IP/PB/14 wydanie 6 z dnia 01.07.2021 r. na podstawie metody HACH LANGE nr 8507
IP/PB/15 wydanie 6 z dnia 01.07.2021 r.
IP/PB/18 wydanie 5 z dnia 01.07.2021 r.
IP/PB/19 wydanie 5 z dnia 01.07.2021 r.
IP/PB/87 wydanie 4 z dnia 01.07.2021 r. na podstawie testu HACH LANGE nr LCK 339
PN-C-04554-4:1999 Załącznik A
PN-EN 27888:1999
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7393-2:2018-04
PN-EN ISO 7887:2012 Metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 9297:1994
na podstawie metody HACH LANGE nr 8027
na podstawie metody HACH LANGE nr 8029
na podstawie metody HACH LANGE nr 8048
na podstawie metody HACH LANGE nr 8051