🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL
Water & wastewaterMicrobiology
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 862 (Jarocin, Poland). Its accreditation scope covers 36 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, wastewater, Water, water intended for human consumption, swimming pool water, Sewage sludge, Wastewater. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Gravimetric method.
At a glance
- Accreditation number: PCA AB 862
- Methods in scope: 36
- Types of test objects: 11
- Techniques used: 11
- City: Jarocin, Poland
- Accreditation number
- AB 862
- Accreditation body
- PCA
- Address
- W JAROCINIE, LABORATORIUM, ul. Gajówka 1, Cielcza, 63-200 Jarocin
- City
- Jarocin, Poland
What this laboratory tests (11)
- Water, wastewater — 14 methods
- Water, water intended for human consumption, swimming pool water — 4 methods
- Sewage sludge — 3 methods
- Wastewater — 3 methods
- Water intended for human consumption — 3 methods
- Water, water intended for human consumption — 3 methods
- Water — 2 methods
- Water (including swimming pool water) — 1 method
- Water intended for human consumption, water — 1 method
- Water intended for human consumption, well water, swimming pool water — 1 method
- Water, wastewater, rainwater and snowmelt water — 1 method
Analytical techniques used (11)
- Spectrophotometric method — 13 methods
- Membrane filtration method — 5 methods
- Gravimetric method — 4 methods
- Electrochemical method — 2 methods
- Plate method (pour plate) — 2 methods
- Titrimetric method — 2 methods
- Conductometric method — 1 method
- Manual method; Automatic method — 1 method
- Nephelometric method — 1 method
- Potentiometric method — 1 method
- Volumetric method — 1 method
Accreditation scope — test methods (36)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water, wastewater | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 2 | Water, wastewater | Ammonium ion concentration Range (0,03 – 130,0) mg/l N-NH4 Range (0,04 – 167) mg/l NH4 |
Spectrophotometric method | PB 24-LCK 302-304 wydanie 4 z dnia 25.09.2011 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 302, LCK 303, LCK 304 | |
| 3 | Water, wastewater | Nitrate concentration Range (1,0 – 60) mg/l NO3 Range (0,23 – 13,5) mg/l N-NO3 |
Spectrophotometric method | PB 24-LCK 339 wydanie 5 z dnia 31.08.2022 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 339 | |
| 4 | Water, wastewater | Nitrite concentration Range (0,05 – 2,0) mg/l NO2 Range (0,015 – 0,60) mg/l N-NO2 |
Spectrophotometric method | PB 24-LCK 341 wydanie 4 z dnia 25.09.2011 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 341 | |
| 5 | Water, wastewater | Total nitrogen concentration Range (1,0 – 500) mg/l |
Spectrophotometric method | PB 24-LCK 138-338 wydanie 5 z dnia 21.08.2014 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 138 i LCK 338 | |
| 6 | Water, wastewater | Chloride concentration Range (5,0 – 5000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 7 | Water, wastewater | Chemical oxygen demand COD-Cr Range (5,0 – 10 000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 8 | Water, wastewater | Total phosphorus concentration Range (0,05 – 200) mg/l P Range (0,15 – 60) mg/l PO4 |
Spectrophotometric method | PB 24-LCK 348-350 wydanie 5 z dnia 21.08.2014 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349, LCK 350 | |
| 9 | Water, wastewater | Biochemical oxygen demand BOD5 Range (3,0 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 10 | Water, wastewater | Biochemical oxygen demand BOD5 Range (0,7 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 11 | Water, wastewater | Sulfate concentration Range (40 – 900) mg/l |
Spectrophotometric method | PB 24-LCK 153-353 wydanie 2 z dnia 01.12.2010 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 153 i LCK 353 | |
| 12 | Water, wastewater | Total organic carbon concentration (TOC) Range (3,0 – 300,0) mg/l |
Spectrophotometric method | PB 24-LCK 385-386 wydanie 2 z dnia 01.12.2010 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 385 i LCK 386 | |
| 13 | Water, wastewater | Free and total chlorine concentration Range (0,10 – 1,5) mg/l |
Spectrophotometric method | PB 24-LCW 510 wydanie 5 z dnia 26.11.2014 r. | na podstawie testu kuwetowego Hach Lange Nr LCW 510 | |
| 14 | Water, wastewater | Iron concentration Range (0,05 – 10) mg/l |
Spectrophotometric method | PB 24-LCK 521 wydanie 5 z dnia 21.08.2014 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 521 | |
| 15 | Water, wastewater, rainwater and snowmelt water | Total suspended solids (TSS) Range (2,0 – 5000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 16 | Wastewater | Sampling for chemical and physical testing Temperature of the collected wastewater sample Range (4,0 – 40) °C |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 17 | Wastewater | Settleable solids Range (0,1 – 10) ml/l |
Volumetric method | PN-72/C-04559/03 | |
| 18 | Wastewater | Concentration of substances extractable with petroleum ether Range (10 – 1000) mg/l |
Gravimetric method | PB-16 wydanie 4 z dnia 21.08.2023 r. | |
| 19 | Water | Sampling for chemical and physical testing Temperature of the water sample taken Range (4,0 – 40) °C |
PN-ISO 5667-5:2017-10 | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5, 7.6, 8.2, 9.4 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584 | ||
| 20 | Water intended for human consumption, well water, swimming pool water | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 21 | Water (including swimming pool water) | Turbidity Range (0,10 – 40) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt. 5.4 | |
| 22 | Water intended for human consumption | Manganese concentration Range (0,015 – 1,0) mg/l |
Spectrophotometric method | PB 24-LCW 032 wydanie 7 z dnia 21.08.2023 r. | na podstawie testu kuwetowego Hach Lange Nr LCW 032 | |
| 23 | Water intended for human consumption | Total calcium and magnesium content (total hardness) Range (1,0 – 20) dH Range (17,9 – 358) mg/l CaCO3 |
Spectrophotometric method | PB 24-LCK 327 wydanie 4 z dnia 25.09.2011 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 327 | |
| 24 | Water intended for human consumption | Colour Range (2 – 200) mg/l Pt |
Spectrophotometric method | PB-23 wydanie 3 z dnia 25.09.2011 r. | |
| 25 | Water intended for human consumption, water | Electrical conductivity Range (100 – 6000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 26 | Water | Total calcium and magnesium content (total hardness) Range (20 – 800) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 27 | Water, water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 28 | Water, water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 29 | Water, water intended for human consumption | Total viable count at 22°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 30 | Water, water intended for human consumption, swimming pool water | Total viable count at 36°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 31 | Water, water intended for human consumption, swimming pool water | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 32 | Water, water intended for human consumption, swimming pool water | Count of bacteria of the genus Legionella Matrix A Procedure 5 (medium BCYE), Procedure 7 (medium GVPC) |
Membrane filtration method | PN-EN ISO 11731:2017-08 | |
| 33 | Water, water intended for human consumption, swimming pool water | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 34 | Sewage sludge | Sampling for chemical, physical, microbiological and biological testing | PN-EN ISO 5667-13:2011 | ||
| 35 | Sewage sludge | Dry matter Range (0,7 – 40) % Water content (calculated) |
Gravimetric method | PN-EN 15934:2013-02 Metoda A | |
| 36 | Sewage sludge | Loss on ignition of dry matter Range (15 – 80) % |
Gravimetric method | PN-EN 15935:2022-01 | |
Reference standards (48)
PB 24-LCK 138-338 wydanie 5 z dnia 21.08.2014 r.
PB 24-LCK 153-353 wydanie 2 z dnia 01.12.2010 r.
PB 24-LCK 302-304 wydanie 4 z dnia 25.09.2011 r.
PB 24-LCK 327 wydanie 4 z dnia 25.09.2011 r.
PB 24-LCK 339 wydanie 5 z dnia 31.08.2022 r.
PB 24-LCK 341 wydanie 4 z dnia 25.09.2011 r.
PB 24-LCK 348-350 wydanie 5 z dnia 21.08.2014 r.
PB 24-LCK 385-386 wydanie 2 z dnia 01.12.2010 r.
PB 24-LCK 521 wydanie 5 z dnia 21.08.2014 r.
PB 24-LCW 032 wydanie 7 z dnia 21.08.2023 r.
PB 24-LCW 510 wydanie 5 z dnia 26.11.2014 r.
PB-16 wydanie 4 z dnia 21.08.2023 r.
PB-23 wydanie 3 z dnia 25.09.2011 r.
PN-72/C-04559/03
PN-77/C-04584
PN-EN 15934:2013-02 Metoda A
PN-EN 15935:2022-01
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 5667-13:2011
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5, 7.6, 8.2, 9.4
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt. 5.4
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.1.2, 6.2, 6.3
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 9297:1994
na podstawie testu kuwetowego Hach Lange Nr LCK 138 i LCK 338
na podstawie testu kuwetowego Hach Lange Nr LCK 153 i LCK 353
na podstawie testu kuwetowego Hach Lange Nr LCK 302, LCK 303, LCK 304
na podstawie testu kuwetowego Hach Lange Nr LCK 327
na podstawie testu kuwetowego Hach Lange Nr LCK 339
na podstawie testu kuwetowego Hach Lange Nr LCK 341
na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349, LCK 350
na podstawie testu kuwetowego Hach Lange Nr LCK 385 i LCK 386
na podstawie testu kuwetowego Hach Lange Nr LCK 521
na podstawie testu kuwetowego Hach Lange Nr LCW 032
na podstawie testu kuwetowego Hach Lange Nr LCW 510