🇵🇱 PRZEDSIĘBIORSTWO INŻYNIERII MIEJSKIEJ Sp. z o.o. PL
Water & wastewater
PRZEDSIĘBIORSTWO INŻYNIERII MIEJSKIEJ Sp. z o.o. is a laboratory accredited by PCA under number AB 831 (Czechowice-Dziedzice, Poland). Its accreditation scope covers 22 test methods in the following areas: Water & wastewater. Test objects include: Water, Wastewater, Rainwater, Snowmelt water, Surface water, Wastewater. Most frequently used techniques: Spectrophotometric method, Gravimetric method, Titrimetric method.
At a glance
- Accreditation number: PCA AB 831
- Methods in scope: 22
- Types of test objects: 5
- Techniques used: 7
- City: Czechowice-Dziedzice, Poland
- Accreditation number
- AB 831
- Accreditation body
- PCA
- Address
- ul. Szarych Szeregów 2, 43-502 Czechowice-Dziedzice, LABORATORIUM, ul. Czysta 5, 43-502 Czechowice-Dziedzice
- City
- Czechowice-Dziedzice, Poland
What this laboratory tests (5)
- Water, Wastewater — 17 methods
- Rainwater, Snowmelt water — 2 methods
- Surface water — 1 method
- Wastewater — 1 method
- Water — 1 method
Analytical techniques used (7)
- Spectrophotometric method — 7 methods
- Gravimetric method — 4 methods
- Titrimetric method — 4 methods
- Electrochemical method — 2 methods
- Manual method — 1 method
- Manual method; Automatic method — 1 method
- Potentiometric method — 1 method
Accreditation scope — test methods (22)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Wastewater | Sampling for chemical and physical testing Temperature of wastewater / of the wastewater sample Range (0,1 – 50,0) oC |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 2 | Surface water | Sampling for chemical and physical testing Temperature of water / of the water sample Range (0,1 – 50,0) oC |
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6 | PN-77/C-04584 | ||
| 3 | Rainwater, Snowmelt water | Sampling for chemical and physical testing | Manual method | PN-ISO 5667-10:2021-11 | |
| 4 | Rainwater, Snowmelt water | Total suspended solids (TSS) Range (5,0 – 2000) mg/l |
Gravimetric method | PN-EN 872:2007+ Ap1: 2007 | |
| 5 | Water, Wastewater | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 6 | Water, Wastewater | Total suspended solids (TSS) Range (5,0 – 2000) mg/l |
Gravimetric method | PN-EN 872:2007+ Ap1: 2007 | |
| 7 | Water, Wastewater | Nitrate nitrogen concentration Range (0,20 – 30) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 8 | Water, Wastewater | Nitrite nitrogen concentration Range (0,030 – 20) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 9 | Water, Wastewater | Total phosphorus concentration Range (0,040 – 50) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010 + Ap2:2010 | |
| 10 | Water, Wastewater | Phosphate phosphorus concentration Range (0,20 – 35) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt. 4 + Ap2:2010 | |
| 11 | Water, Wastewater | Chloride concentration Range (5,0 – 15000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 12 | Water, Wastewater | Biochemical oxygen demand -BOD5 Range (1 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 13 | Water, Wastewater | Chemical oxygen demand COD-Cr Range (30 – 6000) mg/l O2 |
Titrimetric method | PN-ISO 6060:2006 | |
| 14 | Water, Wastewater | Kjeldahl nitrogen concentration Range (1,2 – 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 15 | Water, Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 16 | Water, Wastewater | Ammonium nitrogen concentration Range (1,0 – 1000) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 17 | Water, Wastewater | Substances extractable with petroleum ether Range (3,0 - 1000) mg/l |
Gravimetric method | PB/17 wydanie 3 z dn. 17.06.2019 r. | |
| 18 | Water, Wastewater | Phenol index Range (0,002 – 0,10) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 metoda B | |
| 19 | Water, Wastewater | Sulfate concentration Range (20 – 2000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 20 | Water, Wastewater | Chemical oxygen demand COD-Cr Range (10,0 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 21 | Water, Wastewater | Ammonium nitrogen concentration Range (0,050 – 40) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 22 | Water | Biochemical oxygen demand BOD5 Range (0,6 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
Reference standards (21)
PB/17 wydanie 3 z dn. 17.06.2019 r.
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576/08
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 872:2007+ Ap1: 2007
PN-EN ISO 10523:2012
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 pkt. 4 + Ap2:2010
PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010 + Ap2:2010
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 6060:2006
PN-ISO 6439:1994 metoda B
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994