🇵🇱 PRZEDSIĘBIORSTWO USŁUG WODNYCH PL

PCA AB 828 • Nowogard, Poland • 32 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO USŁUG WODNYCH is a laboratory accredited by PCA under number AB 828 (Nowogard, Poland). Its accreditation scope covers 32 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Water intended for human consumption, Water, Wastewater, Water, Water intended for human consumption, Wastewater. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 828
  • Methods in scope: 32
  • Types of test objects: 5
  • Techniques used: 13
  • City: Nowogard, Poland
Accreditation number
AB 828
Accreditation body
PCA
Address
I SANITARNYCH Sp. z o.o., ul. 3 Maja 14/2, 72-200 Nowogard, LABORATORIUM BADAWCZE, ul. Wojska Polskiego 37
City
Nowogard, Poland

What this laboratory tests (5)

Analytical techniques used (13)

Laboratory locations

Accreditation scope — test methods (32)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2017-10
2 Water, Water intended for human consumption Colour
Range (5 – 70) mg/l Pt
Visual method PN-EN ISO 7887:2012 Metoda D
3 Water, Water intended for human consumption Turbidity
Range (0,10 – 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016
4 Water, Water intended for human consumption Total iron concentration
Range (0,01 – 20) mg/l
Spectrophotometric method PB-07 wydanie 2 z dnia 10.07.2007 | na podstawie testu Merck 1.14761.0001
5 Water, Water intended for human consumption Manganese concentration
Range (0,01 – 2,5) mg/l
Spectrophotometric method PB-08 wydanie 2 z dnia 10.07.2007 | na podstawie testu Merck 1.14770.0001
6 Water, Water intended for human consumption Electrical conductivity
Range (15 – 2500) μS/cm
Conductometric method PN-EN 27888:1999
7 Water, Water intended for human consumption Permanganate index
Range (0,70 – 10) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
8 Water, Water intended for human consumption Total hardness
Range (50 – 500) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
9 Water, Water intended for human consumption Ammonium ion concentration
Range (0,04 – 40) mg/l
Spectrophotometric method PB-11 wydanie 2 z dnia 10.03.2017 | na podstawie testu Merck 1.14752.0001
10 Water, Water intended for human consumption Nitrate concentration
Range (1,6 – 50) mg/l
Spectrophotometric method PB-12 wydanie 1 z dnia 28.03.2008 | na podstawie testu Merck 1.14773.0001
11 Water, Water intended for human consumption Nitrite concentration
Range (0,04 – 0,6) mg/l
Spectrophotometric method PB-13 wydanie 1 z dnia 10.03.2011 | na podstawie testu Merck 1.14776.0001
12 Water, Water intended for human consumption Presence of foreign odour Threshold odour number (TON)
Range 2
Simplified method, paired, non-forced choice PN-EN 1622:2006
13 Water intended for human consumption Presence of foreign taste Threshold flavour number (TFN)
Range 2
Simplified method, paired, non-forced choice PN-EN 1622:2006
14 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (0,0 – 40,0)°C
Manual and automatic method PN-ISO 5667-10 :2021-11 | PN-77/C-04584
15 Water, Wastewater Chemical oxygen demand
COD Range (8 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
16 Water, Wastewater Total nitrogen concentration
Range (1,0 – 400) mg/l
Spectrophotometric method PB-04 wydanie 1 z dnia 20.11.2006 | na podstawie testu Merck 1.14963.0001, 1.14773.0001
17 Water, Wastewater Total phosphorus concentration
Range (0,10 – 100) mg/l
Spectrophotometric method PB-02 wydanie 1 z dnia 14.11.2006 | na podstawie testu Merck 1.14687.0001, 1.14848.0001
18 Water, Wastewater Total suspended solids (TSS)
Range (2 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
19 Water, Wastewater Biochemical oxygen demand
BOD5 Range (1 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
20 Water, Wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6) mg/l O2
Electrochemical method PN-EN 1899-2:2002
21 Water, Water intended for human consumption, Wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
22 Water, Water intended for human consumption, Wastewater Chloride concentration
Range (5,0 – 10000) mg/l
Titrimetric method PN-ISO 9297:1994
23 Water, Water intended for human consumption, Wastewater Sulfate concentration
Range (10 – 250) mg/l
Gravimetric method PN-ISO 9280:2002 z wyłączeniem pkt. 9.2
24 Water, Water intended for human consumption, Wastewater Phosphate concentration
Range (0,10 – 100) mg/l
Spectrophotometric method PB-03 wydanie 1 z dnia 14.11.2006 | na podstawie testu Merck 1.14848.0001
25 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt.4.4.3; 4.4.4; 4.4.5
26 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014 +A1:2017-04
27 Water intended for human consumption Bacteria count, Escherichia coli Membrane filtration method PN-EN ISO 9308-1:2014 +A1:2017-04
28 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
29 Water intended for human consumption Total count of microorganisms on nutrient agar at a temperature of 36oC after 48 h incubation Plate method PN-EN ISO 6222:2004
30 Water intended for human consumption Total count of microorganisms on nutrient agar at a temperature of 22oC after 72 h incubation Plate method PN-EN ISO 6222:2004
31 Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
32 Water intended for human consumption Most probable number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06

Reference standards (37)

PB-02 wydanie 1 z dnia 14.11.2006
PB-03 wydanie 1 z dnia 14.11.2006
PB-04 wydanie 1 z dnia 20.11.2006
PB-07 wydanie 2 z dnia 10.07.2007
PB-08 wydanie 2 z dnia 10.07.2007
PB-11 wydanie 2 z dnia 10.03.2017
PB-12 wydanie 1 z dnia 28.03.2008
PB-13 wydanie 1 z dnia 10.03.2011
PN-77/C-04584
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt.4.4.3; 4.4.4; 4.4.5
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016
PN-EN ISO 7887:2012 Metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10 :2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 9280:2002 z wyłączeniem pkt. 9.2
PN-ISO 9297:1994
na podstawie testu Merck 1.14687.0001, 1.14848.0001
na podstawie testu Merck 1.14752.0001
na podstawie testu Merck 1.14761.0001
na podstawie testu Merck 1.14770.0001
na podstawie testu Merck 1.14773.0001
na podstawie testu Merck 1.14776.0001
na podstawie testu Merck 1.14848.0001
na podstawie testu Merck 1.14963.0001, 1.14773.0001