IZBA ADMINISTRACJI SKARBOWEJ W RZESZOWIE is a laboratory accredited by PCA under number AB 826 (Rzeszów, Poland). Its accreditation scope covers 28 test methods in the following areas: Food & beverages, Materials & polymers. Test objects include: Spirit drinks and bottled spirit, preparations based on ethyl alcohol, Sugar, Textile products, Ethanol-based preparations. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Oscillation method, Infrared spectrometry (FT-IR).
At a glance
- Accreditation number: PCA AB 826
- Methods in scope: 28
- Types of test objects: 15
- Techniques used: 13
- City: Rzeszów, Poland
- Accreditation number
- AB 826
- Accreditation body
- PCA
- Address
- ul. Geodetów 1, 35-959 Rzeszów, PODKARPACKI URZĄD CELNO-SKARBOWY W PRZEMYŚLU
- City
- Rzeszów, Poland
What this laboratory tests (15)
- Spirit drinks and bottled spirit, preparations based on ethyl alcohol — 6 methods
- Sugar — 4 methods
- Textile products — 3 methods
- Ethanol-based preparations — 2 methods
- Organic and inorganic chemicals — 2 methods
- Spirit drinks and bottled spirit — 2 methods
- Chemicals suspected of containing psychoactive substances — 1 method
- E-cigarette liquids — 1 method
- Fruit and vegetable juices and related products (excluding citrus juices) — 1 method
- Fruit and vegetable preserves — 1 method
- Plant material, hemp products and food — 1 method
- Spirit drinks, liquids based on ethyl alcohol — 1 method
- Surfactants — 1 method
- Tobacco products, plant material, smoking products suspected of containing nicotine — 1 method
- Wines — 1 method
Analytical techniques used (13)
- Gas chromatography with flame ionization detection (GC-FID) — 7 methods
- Oscillation method — 4 methods
- Infrared spectrometry (FT-IR) — 3 methods
- Gas chromatography with mass spectrometry detection (GC-MS) — 2 methods
- Photoelectric method — 2 methods
- Polarimetric method — 2 methods
- Refractometric method — 2 methods
- Burning method — 1 method
- Gravimetric method — 1 method
- High-performance liquid chromatography with diode array detection (HPLC-DAD) — 1 method
- Microscopic method — 1 method
- Tensiometric method — 1 method
- Visual method — 1 method
Laboratory locations
- Dział Laboratorium Celno-Skarbowe — ul. Sielecka 9; 37-700 Przemyśl
Accreditation scope — test methods (28)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Customs and Tax Laboratory Department | |||||
| 1 | Spirit drinks and bottled spirit, preparations based on ethyl alcohol | Ethyl alcohol concentration Range (75,00 - 99,80) % (v/v) |
Gas chromatography with flame ionization detection (GC-FID) | PA-13 wydanie nr 8 z 09.04.2020 r. | |
| 2 | Spirit drinks and bottled spirit, preparations based on ethyl alcohol | Isopropyl alcohol concentration Range (0,10 - 5,00) l/hl 100 % etanolu |
Gas chromatography with flame ionization detection (GC-FID) | ILIADe 453:2024/CLEN Method wersja z 02.04.2024 r. | |
| 3 | Spirit drinks and bottled spirit, preparations based on ethyl alcohol | Ethyl methyl ketone concentration Range (0,10 - 5,00) l/hl 100 % etanolu |
Gas chromatography with flame ionization detection (GC-FID) | ILIADe 453:2024/CLEN Method wersja z 02.04.2024 r. | |
| 4 | Spirit drinks and bottled spirit, preparations based on ethyl alcohol | Ethyl alcohol concentration Range (1,00 - 80,00) % (v/v) |
Gas chromatography with flame ionization detection (GC-FID) | PA-55 wydanie nr 6 z 09.04.2020 r. | |
| 5 | Spirit drinks and bottled spirit, preparations based on ethyl alcohol | Isopropyl alcohol concentration Range (0,50 - 15,00) % (v/v) |
Gas chromatography with flame ionization detection (GC-FID) | PA-52 wydanie nr 6 z 09.04.2020 r. | |
| 6 | Spirit drinks and bottled spirit, preparations based on ethyl alcohol | Presence of chloride and/or hypochlorite ions | Visual method | PA-85 wydanie nr 2 z 21.04.2017 r. | |
| 7 | Spirit drinks, liquids based on ethyl alcohol | Ethyl alcohol concentration Range (10,00 - 96,50) % (v/v) |
Oscillation method | Rozporządzenie Komisji (WE) Nr 2870/2000 z dnia 19 grudnia 2000 roku, załącznik 1, metoda B | |
| 8 | Spirit drinks and bottled spirit | Ethyl alcohol concentration Range (10,0 - 96,5) % (v/v) |
Oscillation method | PN-A-79529-4:2005 p.7.2 | |
| 9 | Spirit drinks and bottled spirit | Density Range (0,7900 - 0,9850) g/cm3 |
Oscillation method | PN-A-79529-4:2005 p.6.2 | |
| 10 | Wines | Ethyl alcohol concentration Range (2,0 - 20,0) % (v/v) |
Oscillation method | Rozporządzenie Ministra Rolnictwa i Rozwoju Wsi z dnia 25 czerwca 2022r., załącznik nr 2 (Dz. U. z 2022r. poz. 1469) | |
| 11 | Fruit and vegetable preserves | Content of soluble residues Range (5,0 - 70,0) oBrix |
Refractometric method | Rozporządzenie wykonawcze Komisji (UE) Nr 974/2014 z dnia 11 września 2014 r., załącznik | |
| 12 | Fruit and vegetable juices and related products (excluding citrus juices) | Content of soluble residues Range (10,0 - 70,0) oBrix |
Refractometric method | PN-EN 12143:2000 | |
| 13 | Ethanol-based preparations | Denatonium benzoate (bitrex) concentration Range (0,50 - 20,00) mg/l |
High-performance liquid chromatography with diode array detection (HPLC-DAD) | ILIADe 280:2024/CLEN Method wersja z 13.02.2024 r. | |
| 14 | Ethanol-based preparations | Propylene glycol concentration Range (0,10 - 2,00) % (v/v) |
Gas chromatography with flame ionization detection (GC-FID) | PA-17 wydanie nr 7 z 01.03.2024 r. | |
| 15 | Organic and inorganic chemicals | Melting point Range (41,0 - 170,0) oC |
Photoelectric method | Rozporządzenie Komisji (WE) Nr 440/2008 z dnia 30 maja 2008r., załącznik, cz. A pkt. A.1 p. 1.4.1.3. | |
| 16 | Organic and inorganic chemicals | Boiling point Range (55,0 - 84,0) oC |
Photoelectric method | Rozporządzenie Komisji (WE) Nr 440/2008 z dnia 30 maja 2008r., załącznik, cz. A pkt. A.2 p. 1.4.5. | |
| 17 | Surfactants | Surface tension Range (20,0 - 65,0) mN/m |
Tensiometric method | PN-EN 14370:2005 | |
| 18 | Sugar | Sucrose content Range (99,5 - 100,0) % (m/m) |
Polarimetric method | I Dyrektywa Komisji z dnia 26 lipca 1979 r. (79/796/EWG), Załącznik II, Metoda 10 | |
| 19 | Sugar | Sucrose content Range (99,5 - 99,9) % (m/m) |
Polarimetric method | PN-A-74855-5:1998 | |
| 20 | Sugar | Moisture content as loss on drying Range (0,01 - 0,06) % (m/m) |
Gravimetric method | PN-A-74855-4:1996 | |
| 21 | Sugar | Presence of sucrose | Infrared spectrometry (FT-IR) | PA-66 wydanie nr 4 z 15.01.2019 r. | |
| 22 | Textile products | Presence of natural, synthetic and man-made fibres | Infrared spectrometry (FT-IR) | PA-40 wydanie nr 6 z 01.02.2019 r. | |
| 23 | Textile products | Fibre identification | Microscopic method | PN-P-04604:1972 p.2.9 | |
| 24 | Textile products | Fibre identification | Burning method | PN-P-04604:1972 p.2.8 | |
| 25 | Plant material, hemp products and food | Presence of delta-9-tetrahydrocannabinol | Gas chromatography with mass spectrometry detection (GC-MS) | PA-53 wydanie nr 7 z 13.04.2026 r. | |
| 26 | Chemicals suspected of containing psychoactive substances | Presence of psychoactive substances: 3-MMC (3-metylometkatynon) 5-MeO-MiPT 4-CMC (4-chlorometkatynon, klefedron) 4-BMC (4-bromometkatynon, brefedron) 3-BMC (3-bromometkatynon) APINACA (AKB-48) AB-PINACA 4-MEC (4-metylo-N-etylokatynon) 5-FUR-144 (XLR-11) MDPBP UR-144 Ethcathinone (N-ethylcathinone) Pentedrone (α-methylaminovalerophenone) QUPIC (PB-22) Alpha-PVP (α-PVP) 4-MMC (Mefedron, 4-metylometkatynon) 3-CMC (3-chlorometkatynon, klofedron) 3-CEC (3-chloroetkatynon) 4-CEC (4-chloroetkatynon) Amphetamine (Psychedrine) N-ethylpentylone (Ephylone, BK-EBDP) N-ethylhexedrone (HEX-EN) Caffeine Cocaine |
Infrared spectrometry (FT-IR) | PA-91 wydanie nr 4 z 25.04.2024 r. | |
| 27 | Tobacco products, plant material, smoking products suspected of containing nicotine | Presence of nicotine | Gas chromatography with mass spectrometry detection (GC-MS) | PA-92 wydanie nr 3 z 04.03.2019 r. | |
| 28 | E-cigarette liquids | Nicotine concentration Range (3,75 - 150,00) mg/g |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 20714:2022-05 | |
Reference standards (27)
I Dyrektywa Komisji z dnia 26 lipca 1979 r. (79/796/EWG), Załącznik II, Metoda 10
ILIADe 280:2024/CLEN Method wersja z 13.02.2024 r.
ILIADe 453:2024/CLEN Method wersja z 02.04.2024 r.
PA-13 wydanie nr 8 z 09.04.2020 r.
PA-17 wydanie nr 7 z 01.03.2024 r.
PA-40 wydanie nr 6 z 01.02.2019 r.
PA-52 wydanie nr 6 z 09.04.2020 r.
PA-53 wydanie nr 7 z 13.04.2026 r.
PA-55 wydanie nr 6 z 09.04.2020 r.
PA-66 wydanie nr 4 z 15.01.2019 r.
PA-85 wydanie nr 2 z 21.04.2017 r.
PA-91 wydanie nr 4 z 25.04.2024 r.
PA-92 wydanie nr 3 z 04.03.2019 r.
PN-A-74855-4:1996
PN-A-74855-5:1998
PN-A-79529-4:2005 p.6.2
PN-A-79529-4:2005 p.7.2
PN-EN 12143:2000
PN-EN 14370:2005
PN-EN ISO 20714:2022-05
PN-P-04604:1972 p.2.8
PN-P-04604:1972 p.2.9
Rozporządzenie Komisji (WE) Nr 2870/2000 z dnia 19 grudnia 2000 roku, załącznik 1, metoda B
Rozporządzenie Komisji (WE) Nr 440/2008 z dnia 30 maja 2008r., załącznik, cz. A pkt. A.1 p. 1.4.1.3.
Rozporządzenie Komisji (WE) Nr 440/2008 z dnia 30 maja 2008r., załącznik, cz. A pkt. A.2 p. 1.4.5.
Rozporządzenie Ministra Rolnictwa i Rozwoju Wsi z dnia 25 czerwca 2022r., załącznik nr 2 (Dz. U. z 2022r. poz. 1469)
Rozporządzenie wykonawcze Komisji (UE) Nr 974/2014 z dnia 11 września 2014 r., załącznik