🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL

PCA AB 805 • Warszawa, Poland • 78 methods

Water & wastewaterEnvironment

GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 805 (Warszawa, Poland). Its accreditation scope covers 78 test methods in the following areas: Water & wastewater, Environment. Test objects include: Water, wastewater, Water, Environment: – electromagnetic field in the vicinity of radiocommun…, General environment – noise from installations, equipment and indus…. Most frequently used techniques: Titrimetric method, Spectrophotometric method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 805
  • Methods in scope: 78
  • Types of test objects: 6
  • Techniques used: 16
  • City: Warszawa, Poland
Accreditation number
AB 805
Accreditation body
PCA
Address
ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W OLSZTYNIE
City
Warszawa, Poland

What this laboratory tests (6)

Analytical techniques used (16)

Accreditation scope — test methods (78)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water, wastewater Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method P N-EN 872:2007+Ap1:2007
2 Water, wastewater Dissolved oxygen concentration
Range (0,2 – 20,0) mg/l O2
Titrimetric method P N - E N 2 5 8 1 3:1997
3 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6,0) mg/l O2
Titrimetric method PN-EN 1899-2:2002
4 Water, wastewater Biochemical oxygen demand
BOD5 Range (1 – 6000) mg/l O2
Titrimetric method PN-EN ISO 5815-1:2019-12
5 Water, wastewater Chemical oxygen demand
COD-Cr Range (6,0 – 1000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
6 Water, wastewater Ammonium nitrogen concentration
Range (1,0 – 100) mg/l
Titrimetric method P N - I S O 5 6 6 4 :2002
7 Water, wastewater Nitrite nitrogen concentration
Range (0,0020 – 10) mg/l
Spectrophotometric method PN-EN 26777:1999
8 Water, wastewater Kjeldahl nitrogen concentration
Range (2,0 – 500) mg/l
Titrimetric method PN-EN 25663:2001
9 Water, wastewater Total nitrogen concentration (calculated) PB-01/OL wydanie 1 z dnia 01.02.2020 r.
10 Water, wastewater Total phosphorus concentration
Range (0,010 – 100) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 7
11 Water, wastewater Chloride concentration
Range (4,0 – 5050) mg/l
Titrimetric method PN-ISO 9297:1994
12 Water, wastewater Total organic carbon concentration (TOC)
Range (1,0 – 1000) mg/l
High-temperature combustion with IR detection PN-EN 1484:1999
13 Water, wastewater Ammonium nitrogen concentration
Range (0,025 – 100) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
14 Water, wastewater Anion concentrations
chlorides (2,0 – 200) mg/l sulfates (2,5 – 500) mg/l nitrite nitrogen (0,050 – 50) mg/l nitrate nitrogen (0,050 – 50) mg/l fluorides (0,25 – 50) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
15 Water, wastewater Substances extractable with petroleum ether
Range (5,0 – 200) mg/l
Gravimetric method PN-86/C-04573-01
16 Water Total dissolved solids (TDS)
Range (100 – 5000) mg/l
Gravimetric method PN-EN 15216:2022-03
17 Water Calcium concentration
Range (10 – 200) mg/l
Titrimetric method PN-ISO 6058:1999
18 Water Total content of calcium and magnesium (total hardness)
Range (30 – 500) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
19 Water Total alkalinity
Range (20 – 300) mg/l CaCO3
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
20 Water Colour
Range (2 – 250) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012
21 Water Permanganate index
Range (1,0 – 100) mg/l O2
Titrimetric method P N-EN ISO 8467:2001
22 Water Phosphate phosphorus concentration
Range (0,005 – 50) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 4
23 Water, wastewater Dissolved oxygen concentration
Range (0,2 – 20) mg/l O2
Titrimetric method PN-EN 25813:1997 | PN-ISO 5813:1997
24 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6,0) mg/l O2
Titrimetric method PN-EN 1899-2:2002
25 Water, wastewater Biochemical oxygen demand
BOD5 Range (1 – 6000) mg/l O2
Titrimetric method PN-EN ISO 5815-1:2019-12
26 Water, wastewater Chemical oxygen demand
COD-Cr Range (6,0 – 1000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
27 Water, wastewater Ammonium nitrogen concentration
Range (1,0 – 100) mg/l
Titrimetric method PN-ISO 5664:2002
28 Water, wastewater Ammonium nitrogen concentration, Range; (0,025 – 100) mg/l Spectrophotometric method PN-ISO 7150-1:2002
29 Water, wastewater Nitrite nitrogen concentration
Range (0,0020 – 10) mg/l
Spectrophotometric method PN-EN 26777:1999
30 Water, wastewater Kjeldahl nitrogen concentration
Range (2,0 – 500) mg/l
Titrimetric method PN-EN 25663:2001
31 Water, wastewater Total nitrogen concentration (calculated) PB-01/OL wydanie 1 z dnia 01.02.2020 r.
32 Water, wastewater Total suspended solids (TSS)
Range (2,0 – 500) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
33 Water, wastewater Total phosphorus concentration
Range (0,010 – 100) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 7
34 Wastewater Concentration of polycyclic
aromatic hydrocarbons (PAH) benzo(b)fluoranthene Range (0,0010 – 0,040) μg/l benzo(k)fluoranthene (0,0010 – 0,050) μg/l benzo(a)pyrene (0,000050 – 0,050) μg/l benzo(g,h,i)perylene (0,00040 – 0,040) μg/l indeno (1,2,3-cd)piren (0,00020 – 0,040) μg/l dibenzo(a,h)anthracene (0,0010 – 0,050) μg/l Sum of PAH (calculated)
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PN-EN ISO 17993:2005
35 Water Colour
Range (2 – 250) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012
36 Water Total dissolved solids (TDS)
Range (100 – 2400) mg/l
Gravimetric method PN-EN 15216:2022-03
37 Water Total alkalinity
Range (20 – 500) mg/l CaCO3
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
38 Water Concentration of polycyclic
aromatic hydrocarbons (PAH) naphthalene (0,010 – 0,20) μg/l anthracene (0,0010 – 0,010) μg/l fluoranthene (0,0010 – 0,080) μg/l benzo(b)fluoranthene Range (0,0010 – 0,040) μg/l benzo(k)fluoranthene (0,0010 – 0,050) μg/l benzo(a)pyrene (0,000050 – 0,050) μg/l benzo(g,h,i)perylene (0,00040 – 0,040) μg/l indeno (1,2,3-cd)pirenu (0,00020 – 0,040) μg/l dibenzo(a,h)anthracene (0,0010 – 0,050) μg/l Sum of PAH (calculated)
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PN-EN ISO 17993:2005
39 Water Calcium concentration
Range (10 – 100) mg/l
Titrimetric method PN-ISO 6058:1999
40 Water Total content of calcium and magnesium (total hardness)
Range (30 – 350) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
41 Water Permanganate index
Range (1,0 – 1000) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
42 Water Phosphate phosphorus concentration
Range (0,005 – 50) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 4
43 Water, wastewater Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
44 Water, wastewater Dissolved oxygen concentration
Range (0,2 – 20) mg/l O2
Titrimetric method PN-EN 25813:1997
45 Water, wastewater Dissolved oxygen concentration
Range (0,2 – 20) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04
46 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6,0) mg/l O2
Titrimetric method PN-EN 1899-2:2002
47 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
48 Water, wastewater Biochemical oxygen demand
BOD5 Range (1,0 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
49 Water, wastewater Ammonium nitrogen concentration
Range (1,0 – 200) mg/l
Titrimetric method PN-ISO 5664:2002
50 Water, wastewater Ammonium nitrogen concentration
Range (0,025 – 100) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
51 Water, wastewater Nitrite nitrogen concentration
Range (0,0020 – 70) mg/l
Spectrophotometric method PN-EN 26777:1999
52 Water, wastewater Kjeldahl nitrogen concentration
Range (2,0 – 500) mg/l
Titrimetric method PN-EN 25663:2001
53 Water, wastewater Total nitrogen concentration (calculated ) PB-01/OL wydanie 1 z dn. 01.02.2020 r.
54 Water, wastewater Total phosphorus concentration
Range (0,010 – 100) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02
55 Water, wastewater Orthophosphate concentration
Range (0,015-153) mg/l PO4 Phosphate phosphorus concentration Range (0,005-50) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02
56 Water, wastewater Chemical oxygen demand
COD-Cr Range (6,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
57 Water, wastewater Anion concentrations
chlorides (2,0 – 500) mg/l sulfates (2,5 – 500) mg/l nitrate nitrogen (0,050 – 100) mg/l fluorides (0,25 – 10) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
58 Water, wastewater Metal concentrations
arsenic (0,010 – 10) mg/l boron (0,10 – 100) mg/l barium (0,010 – 100) mg/l selenium (0,010 – 1000) mg/l copper (0,0020 – 100) mg/l lead (0,0050 – 100) mg/l nickel (0,0010 – 100) mg/l manganese (0,0010 – 100) mg/l iron (0,0020 – 100) mg/l zinc (0,010 – 50) mg/l cadmium (0,0010 – 10) mg/l chromium (0,0020 – 50) mg/l aluminium (0,010 – 100) mg/l silver (0,0010 – 1,0) mg/l vanadium (0,010 – 10) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
59 Water, wastewater Mineral oil index
Range (0,050 – 1000) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
60 Water Total alkalinity
Range (20 – 500) mg/l CaCO3
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
61 Water Total dissolved solids (TDS)
Range (100 – 5000) mg/l
Gravimetric method PN-EN 15216:2022-03
62 Water Permanganate index
Range (1,0 – 200) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
63 Water Sodium concentration
Range (0,040 – 40) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 9964-1:1994+Ap1:2009
64 Water Element concentration
Magnesium (1,0 – 200) mg/l Calcium (1,0 – 1000) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
65 Water Potassium concentration
Range (0,020 – 40) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 9964-2:1994
66 Water Total hardness (calculated) PB-07/OL wydanie 1 z dnia 01.02.2020 r.
67 Water Colour
Range (2 – 250) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012
68 Soil Content of petroleum hydrocarbons C12-C35
R a n g e ( 3 0 – 3 0 0 0 ) m g / k g
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 16703:2011
69 Water Sampling for chemical and physical testing Temperature of water / of the water sample taken
Range (0,0 – 30,0) °C
P N - ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-EN ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2 i 6.2 | PN-77/C-04584
70 Water Dissolved oxygen concentration
Range (0,1 – 20,0) mg/l O2
Optical method ISO 17289:2014
71 Wastewater Sampling for chemical and physical testing
Temperature of wastewater /of the collected wastewater sample Range (0,0 – 50,0) °C
Manual method; Automatic method P N - ISO 5667-10:2021-11 | PN-77/C-04584
72 Soil Sampling for chemical and physical testing PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009
73 Water, wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
74 Water, wastewater Electrical conductivity
Range (100 – 20000) μS/cm
Conductometric method PN-EN 27888:1999
75 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (25 – 135) dB
Direct measurement method Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F
76 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F
77 Environment: – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements
in the frequency range from 10 MHz do 40 GHz Range (0,2 – 300) V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
78 Environment: – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength:
in the frequency range from 10 MHz do 40 GHz (calculated)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)

Reference standards (49)

ISO 17289:2014
P N - E N 2 5 8 1 3:1997
P N - I S O 5 6 6 4 :2002
P N - ISO 5667-10:2021-11
P N - ISO 5667-4:2017-10
P N-EN 872:2007+Ap1:2007
P N-EN ISO 8467:2001
PB-01/OL wydanie 1 z dn. 01.02.2020 r.
PB-01/OL wydanie 1 z dnia 01.02.2020 r.
PB-07/OL wydanie 1 z dnia 01.02.2020 r.
PN-77/C-04584
PN-86/C-04573-01
PN-EN 1484:1999
PN-EN 15216:2022-03
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 25813:1997
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 11885:2009
PN-EN ISO 15681-2:2019-02
PN-EN ISO 16703:2011
PN-EN ISO 17993:2005
PN-EN ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2 i 6.2
PN-EN ISO 5667-6:2016-12
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 4
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 7
PN-EN ISO 7887:2012
PN-EN ISO 8467:2001
PN-EN ISO 9377-2:2003
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 10381-4:2007
PN-ISO 10381-5:2009
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5813:1997
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 7150-1:2002
PN-ISO 9297:1994
PN-ISO 9964-1:1994+Ap1:2009
PN-ISO 9964-2:1994
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F