🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL

PCA AB 714 • Lublin, Poland • 25 methods

Water & wastewaterMicrobiology

POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 714 (Lublin, Poland). Its accreditation scope covers 25 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Biological indicators for the control of sterilization efficacy, Faecal swab, Rectal swab, Water. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Culture method.

At a glance

  • Accreditation number: PCA AB 714
  • Methods in scope: 25
  • Types of test objects: 5
  • Techniques used: 11
  • City: Lublin, Poland
Accreditation number
AB 714
Accreditation body
PCA
Address
W LUBLINIE, ul. Uniwersytecka 12, 20-029 Lublin
City
Lublin, Poland

What this laboratory tests (5)

Analytical techniques used (11)

Accreditation scope — test methods (25)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water, Water intended for human consumption Turbidity
Range (0,20 - 10) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
2 Water, Water intended for human consumption Ammonium ion concentration
Range (0,040 - 10) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
3 Water, Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (20 - 750) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
4 Water, Water intended for human consumption Total iron concentration
Range (0,020 - 25) mg/l
Spectrophotometric method PN-ISO 6332:2001 + Ap.1:2016-06
5 Water, Water intended for human consumption Chloride concentration
Range (5,0 - 500) mg/l
Titrimetric method PN-ISO 9297:1994
6 Water, Water intended for human consumption Electrical conductivity
Range (50 - 2500) μS/cm
Conductometric method PN-EN 27888:1999
7 Water, Water intended for human consumption Nitrite concentration
Range (0,006 - 2,50) mg/l
Spectrophotometric method PN-EN 26777:1999
8 Water, Water intended for human consumption Nitrate concentration
Range (0,40 - 100) mg/l
Spectrophotometric method PN-82/C-04576.08
9 Water, Water intended for human consumption Colour
Range (5 - 70) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 p. 6 + Ap.1:2015-06
10 Water, Water intended for human consumption pH
Range (4,0 - 9,0)
Potentiometric method PN-EN ISO 10523:2012
11 Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5: 2017-10
12 Water, Water intended for human consumption Total viable count at 22 oC Plate method (pour plate) PN-EN ISO 6222:2004
13 Water, Water intended for human consumption Total viable count at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004
14 Water, Water intended for human consumption Coliform bacteria count, Escherichia coli Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04
15 Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
16 Water, Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
17 Water, Water intended for human consumption Most probable number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
18 Water, Water intended for human consumption Count of bacteria of the genus Legionella, Matrix A, Procedure 7 (GVPC medium), Procedure 5 (BCYE medium), Matrix B, Procedure 7 (GVPC medium) Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
19 Water Coagulase-positive staphylococci count Membrane filtration method Metodyka PZH ZHK: 2007
20 Water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
21 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6
22 Faecal swab, Rectal swab Presence of enteric rods of the Enterobacteriaceae family –, Salmonella and Shigella Culture method with biochemical and serological confirmation PB-03 Edycja 5 z dnia 03.06.2019 r. | na podstawie wytycznych PZH
23 Faecal swab, Rectal swab Presence of Yersinia spp. Culture method with biochemical confirmation PB-05 Edycja 3 z dnia 20.01.2016 r. | na podstawie wytycznych PZH
24 Biological indicators for the control of sterilization efficacy Presence of the indicator microorganism Geobacillus stearothermophilus Culture method PB-09 Edycja 5 z dnia 05.09.2019 r. | na podstawie producenta testów Attest 1262
25 Biological indicators for the control of sterilization efficacy Presence of the indicator microorganism Bacillus subtilis Culture method PB-10 Edycja 5 z dnia 05.09.2019 r. Na podstawie producenta testów Sporal S

Reference standards (25)

Metodyka PZH ZHK: 2007
PB-03 Edycja 5 z dnia 03.06.2019 r.
PB-05 Edycja 3 z dnia 20.01.2016 r.
PB-09 Edycja 5 z dnia 05.09.2019 r.
PB-10 Edycja 5 z dnia 05.09.2019 r. Na podstawie producenta testów Sporal S
PN-82/C-04576.08
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 p. 6 + Ap.1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 + A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 5667-5: 2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001 + Ap.1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994
na podstawie producenta testów Attest 1262
na podstawie wytycznych PZH