🇵🇱 ALSTOM POLSKA S.A. PL
Materials & polymers
ALSTOM POLSKA S.A. is a laboratory accredited by PCA under number AB 675 (Warszawa, Poland). Its accreditation scope covers 10 test methods in the following areas: Materials & polymers. Test objects include: Metal products and materials, Steel mill products, Welded joints, Welded joints in ferromagnetic materials and products. Most frequently used techniques: Ultrasonic method, Vickers method, X-ray radiographic method.
At a glance
- Accreditation number: PCA AB 675
- Methods in scope: 10
- Types of test objects: 6
- Techniques used: 5
- City: Warszawa, Poland
- Accreditation number
- AB 675
- Accreditation body
- PCA
- Address
- ul. Emilii Plater 53, 00-113 Warszawa, ALSTOM POLSKA S.A. ODDZIAŁ WE WROCŁAWIU, CENTRALNE LABORATORIUM, ul. Fabryczna 12
- City
- Warszawa, Poland
What this laboratory tests (6)
- Metal products and materials — 3 methods
- Steel mill products — 2 methods
- Welded joints — 2 methods
- Welded joints in ferromagnetic materials and products — 1 method
- Welded joints of metallic materials with thicknesses from 8 mm to 100 mm — 1 method
- Welded joints of steel with thicknesses up to 50 mm — 1 method
Analytical techniques used (5)
- Ultrasonic method — 2 methods
- Vickers method — 2 methods
- X-ray radiographic method — 2 methods
- Magnetic particle method — 1 method
- Penetrant testing method — 1 method
Accreditation scope — test methods (10)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Welded joints of steel with thicknesses up to 50 mm | Discontinuities | X-ray radiographic method | PN-EN ISO 17636-1:2023-02 | |
| 2 | Metal products and materials | Discontinuities | X-ray radiographic method | PN-EN ISO 5579:2014-02 | |
| 3 | Welded joints in ferromagnetic materials and products | Surface and subsurface discontinuities | Magnetic particle method | PN-EN ISO 17638:2017-01 | |
| 4 | Metal products and materials | External surface discontinuities | Penetrant testing method | PN-EN ISO 3452-1:2021-12 | |
| 5 | Welded joints of metallic materials with thicknesses from 8 mm to 100 mm | Internal discontinuities | Ultrasonic method | PN-EN ISO 17640:2019-01 | |
| 6 | Metal products and materials | Internal discontinuities | Ultrasonic method | PN-EN ISO 16810:2014-06 | PN-EN ISO 16823:2014-06 | |
| 7 | Welded joints | Mechanical properties: Yield strength Re Proof strength, plastic extension Rp Maximum force Fm Tensile strength Rm Force range F do 400 kN Tensile test at room temperature |
PN-EN ISO 4136:2022-12 | PN-EN ISO 6892-1:2020-05 Metoda B | ||
| 8 | Welded joints | HV hardness Range HV5, HV10, |
Vickers method | PN-EN ISO 9015-1:2011 | PN-EN ISO 6507-1:2018-05 | |
| 9 | Steel mill products | Mechanical properties: Yield strength Re Proof strength, plastic extension Rp Maximum force Fm Tensile strength Rm Percentage elongation after fracture A Force range F do 400 kN Tensile test at room temperaturePenetrant method |
PN-EN ISO 6892-1:2020-05 Metoda B | ||
| 10 | Steel mill products | HV hardness Range HV5, HV10, |
Vickers method | PN-EN ISO 6507-1:2018-05 | |
Reference standards (11)
PN-EN ISO 16810:2014-06
PN-EN ISO 16823:2014-06
PN-EN ISO 17636-1:2023-02
PN-EN ISO 17638:2017-01
PN-EN ISO 17640:2019-01
PN-EN ISO 3452-1:2021-12
PN-EN ISO 4136:2022-12
PN-EN ISO 5579:2014-02
PN-EN ISO 6507-1:2018-05
PN-EN ISO 6892-1:2020-05 Metoda B
PN-EN ISO 9015-1:2011