🇵🇱 INSTYTUT ŁĄCZNOŚCI PL

PCA AB 666 • Warszawa, Poland • 33 methods

AutomotiveEnvironmentElectronics & EMC

INSTYTUT ŁĄCZNOŚCI is a laboratory accredited by PCA under number AB 666 (Warszawa, Poland). Its accreditation scope covers 33 test methods in the following areas: Automotive, Environment, Electronics & EMC. Test objects include: Household appliances, audiovisual equipment, audio-video equipment,…, Transmitting antennas and antenna units of television, radio broadc…, Coaxial cables for feeding various types of transmitting antennas, Environment – electromagnetic field in the vicinity of radiocommuni…. Most frequently used techniques: Measurement method: direct, Direct measurement method.

At a glance

  • Accreditation number: PCA AB 666
  • Methods in scope: 33
  • Types of test objects: 9
  • Techniques used: 2
  • City: Warszawa, Poland
Accreditation number
AB 666
Accreditation body
PCA
Address
PAŃSTWOWY INSTYTUT BADAWCZY, ul. Szachowa 1, 04-894 Warszawa, ZAKŁAD KOMPATYBILNOŚCI ELEKTROMAGNETYCZNEJ, LABORATORIUM BADAŃ EMC
City
Warszawa, Poland

What this laboratory tests (9)

Analytical techniques used (2)

Laboratory locations

Accreditation scope — test methods (33)

No. Test object Methodology / Parameters Technique Reference document
Zakład Kompatybilności Elektromagnetycznej i Sieci Radiowych; Laboratorium Badań EMC
1 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Radiated disturbance emission
Range 9 kHz – 26,5 GHz
Measurement method: direct PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A2:2021-08 | PN-EN 55012:2012 | PN-EN IEC 55014-1:2021-08 | PN-EN 55022:2011 | PN-EN 55025:2017-04 | NO-06-A500:2012 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 55016-2-3:2017-06/A2:2024-03 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-E-05118:1977 | PN-E-05118:1977/Az1:2008 | PN-EN 50121-2:2017-06 | PN-EN 50121-3-1:2017-05 | PN-EN 50121-3-1:2017-05/A1:2019-07 | PN-EN 50561-1:2013-12 | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A1:2021-05
2 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Emission of conducted disturbances – disturbance voltages
Range 9 kHz – 30 MHz
Measurement method: direct PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A2:2021-08 | PN-EN IEC 55014-1:2021-08 | PN-EN 55022:2011 | PN-EN 55025:2017-04 | NO-06-A500:2012 | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-EN 50121-2:2017-06 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50561-1:2013-12 | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A1:2021-05
3 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Emission of conducted disturbances – disturbance power Measurement method: direct PN-EN IEC 55014-1:2021-08 | PN-EN 55016-2-2:2011
4 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Emission of conducted disturbances – voltage fluctuations and flicker of the supply voltage Measurement method: direct PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN IEC 61000-3-11:2020-01
5 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to electrostatic discharge (ESD)
Range do 30 kV
PN-EN 61000-4-2:2011 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-EN 55035:2017-09
6 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Odporność na pola elektromagnetyczne o częstotliwościach radiowych
Range (20 – 6000) MHz
PN-EN 61000-4-3:2021-06 | NO-06-A500:2012 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-EN 61000-4-20:2011 | PN-EN 55016-2-4:2005 | PN-EN 55035:2017-09
7 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Odporność na pola radiowe w bli- skiej odległości
Range 9 kHz – 150 kHz Range 150 kHz – 26 MHz
PN-EN 61000-4-39:2017-07 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07
8 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to fast transients
Range do 5,5 kV
PN-EN 61000-4-4:2013-05 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-EN 55035:2017-09
9 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to surges
Range do 5 kV
PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 60601-1-2:2015-1 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-EN 55035:2017-09
10 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to conducted disturbances induced by radio-frequency fields
Range (0,15 – 80) MHz
PN-EN IEC 61000-4-6:2024-03 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-EN 55016-2-4:2005 | NO-06-A500:2012 | PN-EN 55035:2017-09
11 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to voltage dips and power supply interruptions
Range do 16 A (1-fazowe oraz DC)
PN-EN IEC 61000-4-11:2020-11 | PN-EN 61000-4-29:2004 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-EN 55035:2017-09
12 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to power-frequency magnetic field
Range do 100 A/m
PN-EN 61000-4-8:2010 | PN-EN 55035:2017-09
13 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to damped oscillatory wave PN-EN IEC 61000-4-18:2019-08
14 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to damped sinusoidal wave PN-EN 61000-4-12:2017-12
15 Power lines and substations Power quality
Range dla sieci 50 Hz sieć jednofazowa, trójfazowa, konfiguracje: trójkąt, gwiazda i inne według możliwości pomiaro- wych przyrządu Napięcie zasilania jednofazowe (58 – 400) V Napięcie zasilania trójfazowe (100 – 693) V Supply current do 16A
Measurement method: direct PN-EN 61000-4-30:2015-05
16 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Emisja harmonicznych do sieci zasilania (urządzenia jednofazowe i trójfazowe)
Range (0,1 – 100) %
Measurement method: direct PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-2:2019-04/A2:2024-12 | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | PN-EN 61000-3-12:2012 | PN-EN 61000-3-12:2012/A1:2024-11
17 Shielded cabins and other shielded enclosures Shielding effectiveness
Range (10 – 18 000 000) kHz
Measurement method: direct NO-06-A501:2009 +A1:2018
18 Test sites for radiated emission measurements NSA factor / Field distribution (VSWR)
Range (30 – 1000) MHz / (1 – 18) GHz
PN-EN 55016-1-4:2019:04 | PN-EN 55016-1-4:2019:04/A1:2021-03 | PN-EN 55016-1-4:2019:04/A2:2024-01
19 Transmitting antennas and antenna units of television, radio broadcasting and radiocommunication antenna systems, professional and general-purpose receiving antennas Radiation characteristics
Range (30 MHz – 18 GHz)
Measurement method: direct PN-T-84712-2:1996
20 Transmitting antennas and antenna units of television, radio broadcasting and radiocommunication antenna systems, professional and general-purpose receiving antennas Energy gain
Range (30 MHz – 18 GHz)
Measurement method: direct PN-T-84712-3:1996
21 Transmitting antennas and antenna units of television, radio broadcasting and radiocommunication antenna systems, professional and general-purpose receiving antennas Standing wave ratio SWR
Range (30 MHz –18 GHz)
Measurement method: direct PN-T-84710-02:1984
22 Transmitting antennas and antenna units of television, radio broadcasting and radiocommunication antenna systems, professional and general-purpose receiving antennas Front-to-back radiation ratio
Range (30 MHz – 18 GHz)
Measurement method: direct PN-T-84710-01:1984
23 Transmitting antennas and antenna units of television, radio broadcasting and radiocommunication antenna systems, professional and general-purpose receiving antennas Antenna immunity to orthogonal polarisation
Range (30 MHz – 18 GHz)
Measurement method: direct PN-T-84710-02:1984
24 Coaxial cables for feeding various types of transmitting antennas Attenuation per unit length
Range (9 kHz – 8,5 GHz)
Measurement method: direct IEC 1196-1:1995
25 Coaxial cables for feeding various types of transmitting antennas Standing wave ratio
Range (9 kHz – 8,5 GHz)
Measurement method: direct IEC 1196-1:1995
26 Coaxial cables for feeding various types of transmitting antennas Shortening factor
Range (9 kHz – 8,5 GHz)
Measurement method: direct IEC 1196-1:1995
27 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Electric field strength in the frequency range: 27MHz – 60 GHz
Range 1 V/m – 350 V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (tekst jednolity Dz.U.2022, poz. 2630)
28 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength in the frequency range: 3 kHz – 3 MHz
Range 0,5 A/m – 100 A/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (tekst jednolity Dz.U.2022, poz. 2630)
29 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength in the frequency range: 27MHz – 60 GHZ (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
30 Environment – electromagnetic field in the vicinity of radiocommunication installations: selective measurements Electric field strength in the frequency range: 27 MHz – 6 GHz
Range 0,1 V/m – 200 V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (tekst jednolity Dz.U.2022, poz. 2630)
31 Environment – electromagnetic field in the vicinity of radiocommunication installations: selective measurements Magnetic field strength in the frequency range: 27 MHz – 6 GHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
32 Workplace environment – electromagnetic fields originating from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) Electric field strength in the frequency range: 800 MHz – 60 GHz
Range 1 V/m – 350 V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. ( tekst jednolity Dz.U. z 2018 r. poz. 331)
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s.89-131
33 Workplace environment – electromagnetic fields originating from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) Magnetic field strength in the frequency range: 800 MHz – 60 GHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. ( tekst jednolity Dz.U. z 2018 r. poz. 331)
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s.89-131

Reference standards (66)

IEC 1196-1:1995
NO-06-A500:2012
NO-06-A501:2009 +A1:2018
PN-E-05118:1977
PN-E-05118:1977/Az1:2008
PN-EN 50121-2:2017-06
PN-EN 50121-3-1:2017-05
PN-EN 50121-3-1:2017-05/A1:2019-07
PN-EN 50121-3-2:2017-04
PN-EN 50121-3-2:2017-04/A1:2019-07
PN-EN 50561-1:2013-12
PN-EN 55011:2016-05
PN-EN 55011:2016-05/A1:2017-06
PN-EN 55011:2016-05/A2:2021-08
PN-EN 55012:2012
PN-EN 55016-1-4:2019:04
PN-EN 55016-1-4:2019:04/A1:2021-03
PN-EN 55016-1-4:2019:04/A2:2024-01
PN-EN 55016-2-1:2014-09
PN-EN 55016-2-1:2014-09/A1:2017-12
PN-EN 55016-2-2:2011
PN-EN 55016-2-3:2017-06
PN-EN 55016-2-3:2017-06/A1:2020-01
PN-EN 55016-2-3:2017-06/A2:2024-03
PN-EN 55016-2-4:2005
PN-EN 55022:2011
PN-EN 55025:2017-04
PN-EN 55032:2015-09
PN-EN 55032:2015-09/A1:2021-05
PN-EN 55035:2017-09
PN-EN 60601-1-2:2015-1
PN-EN 60601-1-2:2015-11
PN-EN 60601-1-2:2015-11/A1:2021-07
PN-EN 61000-3-12:2012
PN-EN 61000-3-12:2012/A1:2024-11
PN-EN 61000-3-2:2019-04
PN-EN 61000-3-2:2019-04/A1:2021-08
PN-EN 61000-3-2:2019-04/A2:2024-12
PN-EN 61000-3-3:2013-10
PN-EN 61000-3-3:2013-10/A1:2019-10
PN-EN 61000-3-3:2013-10/A2:2022-04
PN-EN 61000-4-12:2017-12
PN-EN 61000-4-20:2011
PN-EN 61000-4-29:2004
PN-EN 61000-4-2:2011
PN-EN 61000-4-30:2015-05
PN-EN 61000-4-39:2017-07
PN-EN 61000-4-3:2021-06
PN-EN 61000-4-4:2013-05
PN-EN 61000-4-5:2014-10
PN-EN 61000-4-5:2014-10/A1:2018-01
PN-EN 61000-4-7:2007
PN-EN 61000-4-7:2007/A1:2011
PN-EN 61000-4-8:2010
PN-EN IEC 55014-1:2021-08
PN-EN IEC 61000-3-11:2020-01
PN-EN IEC 61000-4-11:2020-11
PN-EN IEC 61000-4-18:2019-08
PN-EN IEC 61000-4-6:2024-03
PN-T-84710-01:1984
PN-T-84710-02:1984
PN-T-84712-2:1996
PN-T-84712-3:1996
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s.89-131
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (tekst jednolity Dz.U.2022, poz. 2630)