🇵🇱 TELE-COM Sp. z o. o. PL
EnvironmentElectronics & EMCMaterials & polymers
TELE-COM Sp. z o. o. is a laboratory accredited by PCA under number AB 529 (Poznań, Poland). Its accreditation scope covers 31 test methods in the following areas: Environment, Electronics & EMC, Materials & polymers. Test objects include: Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment − electromagnetic field from equipment used i…, Workplace environment − electromagnetic field originating from indu…, Workplace environment − electromagnetic field originating from radi…. Most frequently used techniques: Direct measurement method.
At a glance
- Accreditation number: PCA AB 529
- Methods in scope: 31
- Types of test objects: 9
- Techniques used: 1
- City: Poznań, Poland
- Accreditation number
- AB 529
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAWCZE, ul. Jawornicka 8, 60-968 Poznań
- City
- Poznań, Poland
What this laboratory tests (9)
- Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) — 5 methods
- Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units — 4 methods
- Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - inductive metal detectors — 4 methods
- Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld and cordless radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - equipment emitting an electromagnetic field for purposes other than communication or location — 4 methods
- Environment – electromagnetic field in the vicinity of electric power substations and power lines — 3 methods
- Workplace environment − electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices — 3 methods
- Workplace environment − electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry — 3 methods
- Workplace environment − electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems — 3 methods
- Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) — 2 methods
Analytical techniques used (1)
- Direct measurement method — 21 methods
Accreditation scope — test methods (31)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - inductive metal detectors | Electric field strength: in the frequency range from 5 Hz do 100 kHz Range 1 V/m – 50 kV/m in the frequency range from 0,1 MHz do 6 GHz Range (0,8 – 1000) V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 2 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - inductive metal detectors | Magnetic field strength: in the frequency range from 0,1 MHz do 30 MHz Range (0,01 – 16) A/m in the frequency range from 30 MHz do 1000 MHz Range (0,01 – 10) A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 3 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - inductive metal detectors | Magnetic flux density: in the frequency range from 5 Hz do 500 Hz Range 1 μT – 20 mT in the frequency range from 500 Hz do 600 kHz Range (30 nT – 20 mT) |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 4 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - inductive metal detectors | Magnetic field strength: in the frequency range from 5 Hz do 600 kHz in the frequency range from 0,8 GHz do 6 GHz (calculated) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | ||
| 5 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld and cordless radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - equipment emitting an electromagnetic field for purposes other than communication or location | Electric field strength: in the frequency range from 0,1 MHz do 6 GHz Range (0,8 – 1000) V/m in the frequency range from 6 GHz do 90 GHz Range (0,8 – 300) V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 6 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld and cordless radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - equipment emitting an electromagnetic field for purposes other than communication or location | Magnetic field strength: in the frequency range from 0,1 MHz do 30 MHz Range (0,01 – 16) A/m in the frequency range from 30 MHz do 1000 MHz Range (0,01 – 10) A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 7 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld and cordless radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - equipment emitting an electromagnetic field for purposes other than communication or location | Magnetic flux density: in the frequency range from 500 Hz do 600 kHz Range (30 nT – 20 mT) |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 8 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld and cordless radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - equipment emitting an electromagnetic field for purposes other than communication or location | Magnetic field strength: in the frequency range from 5 Hz do 600 kHz in the frequency range from 0,8 GHz do 90 GHz (calculated) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | ||
| 9 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | Electric field strength: in the frequency range from 0,1 MHz do 6 GHz Range (0,8 – 1000) V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 10 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | Magnetic field strength: in the frequency range from 0,1 MHz do 30 MHz Range (0,01 – 16) A/m in the frequency range from 30 MHz do 1000 MHz Range (0,01 – 10) A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 11 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | Magnetic flux density: in the frequency range from 5 Hz do 600 kHz Range (30 nT – 20 mT) |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 12 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | Magnetic field strength: in the frequency range from 5 Hz do 600 kHz in the frequency range from 0,8 GHz do 6 GHz (calculated) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | ||
| 13 | Workplace environment − electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices | Electric field strength: in the frequency range from 5 Hz do 100 kHz Range 1 V/m – 50 kV/m |
Direct measurement method | PiMOŚP nr 4(90) 2016 str. 151-180 | |
| 14 | Workplace environment − electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices | Magnetic field strength: in the frequency range from 5 Hz do 100 kHz (calculated) |
PiMOŚP nr 4(90) 2016 str. 151-180 | ||
| 15 | Workplace environment − electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices | Magnetic flux density: in the frequency range from 5 Hz do 500 Hz Range 1 μT – 20 mT in the frequency range from 500 Hz do 100 kHz) Range (30 nT – 20 mT) |
Direct measurement method | PiMOŚP nr 4(90) 2016 str. 151-180 | |
| 16 | Workplace environment − electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | Electric field strength: in the frequency range from 45 Hz do 55 Hz Range (0,1 – 50) kV/m |
Direct measurement method | PiMOŚP nr 4(90) 2016 str. 91-150 | |
| 17 | Workplace environment − electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | Magnetic field strength: in the frequency range from 45 Hz do 55 Hz (calculated) |
PiMOŚP nr 4(90) 2016 str. 91-150 | ||
| 18 | Workplace environment − electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | Magnetic flux density: in the frequency range from 45 Hz do 55 Hz Range 1 μT – 20 mT |
Direct measurement method | PiMOŚP nr 4(90) 2016 str. 91-150 | |
| 19 | Workplace environment − electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems | Electric field strength: in the frequency range from 0,1 MHz do 300 MHz Range (0,8 – 1000) V/m in the frequency range from 0,3 GHz do 6 GHz Range (0,8 – 1000) V/m in the frequency range from 6 GHz do 90 GHz Range (0,8 – 280) V/m |
Direct measurement method | PiMOŚP nr 2(92) 2017 str. 89-131 | |
| 20 | Workplace environment − electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems | Magnetic field strength: in the frequency range from 0,3 MHz do 30 MHz Range (0,01 – 16) A/m in the frequency range from 30 MHz do 1000 MHz Range (0,01 – 10) A/m |
Direct measurement method | PiMOŚP nr 2(92) 2017 str. 89-131 | |
| 21 | Workplace environment − electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems | Magnetic field strength: in the frequency range from 0,8 GHz do 90 GHz (calculated) |
PiMOŚP nr 2(92) 2017 str. 89-131 | ||
| 22 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Electric field strength: in the frequency range 50 Hz Range (0,1 – 50) kV/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 23 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic flux density: in the frequency range 50 Hz Range (1 μT – 20 mT) |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 24 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic field strength: in the frequency range 50 Hz (calculated) |
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 25 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Electric field strength: in the frequency range from 0,1 MHz do 300 MHz Range (0,8 – 1000) V/m in the frequency range from 0,3 GHz do 6 GHz Range (0,8 – 1000) V/m in the frequency range from 6 GHz do 90 GHz Range (0,8 – 280) V/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 26 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic field strength: in the frequency range from 100 kHz do 30 MHz Range (0,01 – 16) A/m in the frequency range from 30 MHz do 1 GHz Range (0,01 – 10) A/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 27 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic field strength: in the frequency range: from 10 MHz do 90 GHz (calculated) |
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 28 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic flux density: in the frequency range from 5 Hz do 600 kHz Range (30 nT – 20 mT) |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 29 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic field strength: in the frequency range from 5 Hz do 600 kHz (calculated) |
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 30 | Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) | Electric field strength: in the frequency range from 0,1 MHz do 90 GHz Range (0,8 – 300) V/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 31 | Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) | Magnetic field strength: in the frequency range from 10 MHz do 90 GHz (calculated) |
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
Reference standards (6)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r.
PiMOŚP nr 2(92) 2017 str. 89-131
PiMOŚP nr 4(90) 2016 str. 151-180
PiMOŚP nr 4(90) 2016 str. 91-150
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)