🇵🇱 Atomik sp. z o.o. PL

PCA AB 505 • Warszawa, Poland • 12 methods

Electronics & EMCEnvironment

Atomik sp. z o.o. is a laboratory accredited by PCA under number AB 505 (Warszawa, Poland). Its accreditation scope covers 12 test methods in the following areas: Electronics & EMC, Environment. Test objects include: Environment – electromagnetic field in the vicinity of electric pow…, Workplace environment – electromagnetic field from transmitting dev…, Environment – electromagnetic field in the vicinity of radiocommuni…, Environment – electromagnetic field in the vicinity of radiocommuni…. Most frequently used techniques: Direct measurement method.

At a glance

  • Accreditation number: PCA AB 505
  • Methods in scope: 12
  • Types of test objects: 5
  • Techniques used: 1
  • City: Warszawa, Poland
Accreditation number
AB 505
Accreditation body
PCA
Address
ul. Koszykowa 49A, lok. 26, 00-659 Warszawa, Laboratorium badawcze, al. Komisji Edukacji Narodowej nr 105, lok. 78
City
Warszawa, Poland

What this laboratory tests (5)

Analytical techniques used (1)

Accreditation scope — test methods (12)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Electric field strength:
in the frequency range 45 - 55 Hz Range (1,0 – 30000) V/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
2 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic flux density:
in the frequency range 45 - 55 Hz Range 1μT – 19 mT
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
3 Workplace environment – electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.) Electric field strength:
in the frequency range From 75 MHz do 90 GHz Range (1,0 – 243) V/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
4 Workplace environment – electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 75 MHz do 1,0 GHz Range (0,011 – 1,5) A/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
5 Workplace environment – electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 800 MHz do 90 GHz (calculated)
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
6 Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength:
in the frequency range 50 Hz Range (1,0 – 30000) V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
7 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density:
in the frequency range 50 Hz Range 1μT – 19 mT
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
8 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength:
in the frequency range 50 Hz (calculated)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
9 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength:
in the frequency range from 75 MHz do 90 GHz Range (1,0 – 243) V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
10 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 75 MHz do 90 GHz (calculated)
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
11 Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Electric field strength:
in the frequency range from 27 MHz do 3 GHz Range (0,1 – 200) V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
12 Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Magnetic field strength:
in the frequency range from 27 MHz do 3 GHz (calculated)
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)

Reference standards (4)

Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)