🇵🇱 Atomik sp. z o.o. PL

PCA AB 505 • Warszawa, Poland • 12 methods

Environment

Atomik sp. z o.o. is a laboratory accredited by PCA under number AB 505 (Warszawa, Poland). Its accreditation scope covers 12 test methods in the following areas: Environment. Test objects include: Environment – electromagnetic field in the vicinity of electric pow…, Workplace environment – electromagnetic field from transmitting dev…, Environment – electromagnetic field in the vicinity of radiocommuni…, Environment – electromagnetic field in the vicinity of radiocommuni…. Most frequently used techniques: Direct measurement method.

At a glance

  • Accreditation number: PCA AB 505
  • Methods in scope: 12
  • Types of test objects: 5
  • Techniques used: 1
  • City: Warszawa, Poland
Accreditation number
AB 505
Accreditation body
PCA
Address
ul. Koszykowa 49A, lok. 26, 00-659 Warszawa, Laboratorium badawcze, al. Komisji Edukacji Narodowej nr 105, lok. 78
City
Warszawa, Poland

What this laboratory tests (5)

Analytical techniques used (1)

Certificate information

Issue date
24.02.2025
Issue no.
19

Accreditation scope — test methods (12)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Electric field strength:
in the frequency range 45 - 55 Hz Range (1,0 – 30000) V/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
2 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic flux density:
in the frequency range 45 - 55 Hz Range 1μT – 19 mT
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
3 Workplace environment – electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.) Electric field strength:
in the frequency range From 75 MHz do 90 GHz Range (1,0 – 243) V/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
4 Workplace environment – electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 75 MHz do 1,0 GHz Range (0,011 – 1,5) A/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
5 Workplace environment – electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 800 MHz do 90 GHz (calculated)
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
6 Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength:
in the frequency range 50 Hz Range (1,0 – 30000) V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
7 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density:
in the frequency range 50 Hz Range 1μT – 19 mT
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
8 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength:
in the frequency range 50 Hz (calculated)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
9 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength:
in the frequency range from 75 MHz do 90 GHz Range (1,0 – 243) V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
10 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 75 MHz do 90 GHz (calculated)
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
11 Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Electric field strength:
in the frequency range from 27 MHz do 3 GHz Range (0,1 – 200) V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
12 Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Magnetic field strength:
in the frequency range from 27 MHz do 3 GHz (calculated)
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)

Reference standards (4)

Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20505