🇵🇱 EKOMIAR S.C. PL

PCA AB 417 • Toruń, Poland • 12 methods

EnvironmentElectronics & EMCConstructionMaterials & polymers

EKOMIAR S.C. is a laboratory accredited by PCA under number AB 417 (Toruń, Poland). Its accreditation scope covers 12 test methods in the following areas: Environment, Electronics & EMC, Construction, Materials & polymers. Test objects include: Workplace environment – air, Workplace environment – electromagnetic field, Workplace environment – indoor electric lighting, Workplace environment – noise. Most frequently used techniques: Direct measurement method, Gravimetric method, Direct measurement method (simplified).

At a glance

  • Accreditation number: PCA AB 417
  • Methods in scope: 12
  • Types of test objects: 5
  • Techniques used: 4
  • City: Toruń, Poland
Accreditation number
AB 417
Accreditation body
PCA
Address
K. MAKARUK, G. DŁUŻNIEWSKA, ul. Podgórna 21/10,, 87-100 Toruń, LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Żółkiewskiego 37/41,
City
Toruń, Poland

What this laboratory tests (5)

Analytical techniques used (4)

Accreditation scope — test methods (12)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment – electromagnetic field Electric field strength
in the frequency range from 50 Hz do 30 MHz Range 1 V/m - 50 kV/m, from 0,8 do 3 GHz Range (1 - 500) V/m
Direct measurement method PN-T-06580-3:2002 z wyłączeniem p. 2.1.4.2 Metoda dostosowana do obszaru regulowanego
2 Workplace environment – electromagnetic field Magnetic flux density
in the frequency range from 50 Hz do 500 kHz Range 30 nT - 19 mT Magnetic field strength in the frequency range from 100 kHz do 30 MHz Range (0,03 - 20) A/m
Direct measurement method PN-T-06580-3:2002 z wyłączeniem p. 2.1.4.2 Metoda dostosowana do obszaru regulowanego
3 Workplace environment – electromagnetic field Magnetic field strength in the frequency range from 800 MHz to 3 GHz (calculated) PN-T-06580-3:2002 z wyłączeniem p. 2.1.4.2 Metoda dostosowana do obszaru regulowanego
4 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic flux density:
in the frequency range from 20 do 50 Hz Range (1 μT - 19 mT)
Direct measurement method (simplified) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
5 Workplace environment – air Sampling for the assessment of occupational exposure to:
dust agents – inhalable fraction – respirable fraction organic substances inorganic substances – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
6 Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
7 Workplace environment – air Concentration of harmful dust agents - inhalable fraction:
Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Range (0,2 - 20) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
8 Workplace environment – air Concentration of harmful dust agents - respirable fraction:
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,2 - 20) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
9 Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (30 - 134) dB C-weighted peak sound pressure level Range (40 - 137) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt 10 i strategię 3 – pkt 11
10 Workplace environment – noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt 10 i strategię 3 – pkt 11
11 Workplace environment – indoor electric lighting Illuminance
Range (20 - 9000) lx
Direct measurement method PN-E/83-04040.3 | PB-02 wydanie 3 z dnia 20.09.2022 r.
12 Workplace environment – indoor electric lighting Illuminance uniformity (calculated) PN-E/83-04040.3 | PB-02 wydanie 3 z dnia 20.09.2022 r.

Reference standards (11)

PB-02 wydanie 3 z dnia 20.09.2022 r.
PN-E/83-04040.3
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – pkt 10 i strategię 3 – pkt 11
PN-N-01307:1994
PN-T-06580-3:2002 z wyłączeniem p. 2.1.4.2 Metoda dostosowana do obszaru regulowanego
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180