🇵🇱 MIEJSKIE WODOCIĄGI I KANALIZACJA W BYDGOSZCZY PL
Water & wastewaterMicrobiology
MIEJSKIE WODOCIĄGI I KANALIZACJA W BYDGOSZCZY is a laboratory accredited by PCA under number AB 396 (Bydgoszcz, Poland). Its accreditation scope covers 67 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Wastewater, Water, water intended for human consumption, wastewater, Wastewater, Rainwater and snowmelt water. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Flame atomic absorption spectrometry (FAAS).
At a glance
- Accreditation number: PCA AB 396
- Methods in scope: 67
- Types of test objects: 8
- Techniques used: 18
- City: Bydgoszcz, Poland
- Accreditation number
- AB 396
- Accreditation body
- PCA
- Address
- - Spółka z ograniczoną odpowiedzialnością, ul. Toruńska 103, 85-817 Bydgoszcz, CENTRALNE LABORATORIUM BADANIA WODY I ŚCIEKÓW, ul. Koronowska 96
- City
- Bydgoszcz, Poland
What this laboratory tests (8)
- Water, water intended for human consumption — 32 methods
- Wastewater — 25 methods
- Water, water intended for human consumption, wastewater — 3 methods
- Wastewater, Rainwater and snowmelt water — 2 methods
- Water, wastewater — 2 methods
- Swimming pool water — 1 method
- Water intended for human consumption — 1 method
- Water, water intended for human consumption, wastewater, rainwater and snowmelt water — 1 method
Analytical techniques used (18)
- Spectrophotometric method — 16 methods
- Titrimetric method — 10 methods
- Flame atomic absorption spectrometry (FAAS) — 6 methods
- Membrane filtration method — 6 methods
- Gas chromatography with flame ionization detection (GC-FID) — 3 methods
- Gravimetric method — 3 methods
- Conductometric method — 2 methods
- Electrochemical method — 2 methods
- Gas chromatography with electron capture detection (GC-ECD) — 2 methods
- Inductively coupled plasma mass spectrometry (ICP-MS) — 2 methods
- Ion chromatography with conductometric detection (IC-CD) — 2 methods
- Plate method (pour plate) — 2 methods
- Potentiometric method — 2 methods
- Spectrometry method in the infrared range IR — 2 methods
- Cold vapour atomic fluorescence spectrometry (CVAFS) — 1 method
- and 3 more
Accreditation scope — test methods (67)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing Temperature of the water sample taken Range (5,0 – 50,0) °C |
PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 6.5 | PN-77/C-04584 | ||
| 2 | Water, water intended for human consumption | Electrical conductivity Range 10 μS/cm – 12,9 mS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 3 | Water, water intended for human consumption | Nitrate concentration Range (0,44 – 100) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 4 | Water, water intended for human consumption | Nitrite concentration Range (0,006 – 0,823) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 5 | Water, water intended for human consumption | Chloride concentration Range (5 – 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 6 | Water, water intended for human consumption | Manganese concentration Range (0,040 – 5,0) mg/l |
Spectrophotometric method | PN-92/C-04590.02 | |
| 7 | Water, water intended for human consumption | Orthophosphate concentration Range (0,11 – 1,15) mg/l P2O5 Range (0,15 – 1,54) mg/l PO43- |
Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 | |
| 8 | Water, water intended for human consumption | Total content of calcium and magnesium (total hardness) Range (5 – 500) mg/l CaCO3 |
Titrimetric method | P N - I SO 6059:1999 | |
| 9 | Water, water intended for human consumption | Anion concentrations fluorides (0,02 – 2) mg/l bromates (0,0025 – 0,5) mg/l chlorides (0,50 – 200) mg/l bromides (0,05 – 10) mg/l nitrates (0,40 – 20) mg/l sulfates (1 – 200) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PB-15(C) wyd. III z dnia 01.02.2017 r. | |
| 10 | Water, water intended for human consumption | Calcium concentration Range (0,5 – 500) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-EN ISO 7980:2002 | |
| 11 | Water, water intended for human consumption | Magnesium concentration Range (0,05 – 50) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-EN ISO 7980:2002 | |
| 12 | Water, water intended for human consumption | Sodium concentration Range (0,2 – 200) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 9964-1:1994+Ap1:2009 | |
| 13 | Water, water intended for human consumption | Potassium concentration Range (0,2 – 200) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 9964-2:1994 | |
| 14 | Water, water intended for human consumption | Ammonium ion concentration Range (0,06 – 1,29) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 15 | Water, water intended for human consumption | Mercury concentration Range (0,0003 – 0,0050) mg/l |
Cold vapour atomic fluorescence spectrometry (CVAFS) | PN-EN ISO 17852:2009 | |
| 16 | Water, water intended for human consumption | Sulfate concentration Range (10 – 1000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 17 | Water, water intended for human consumption | Element concentration Antimony (1,0 – 2000) μg/l Arsenic (1,0 – 2000) μg/l Barium (5,0 – 2000) μg/l Boron (5,0 – 10000) μg/l Chromium (1,0 – 2000) μg/l Zinc (1,0 – 20000) μg/l Aluminium (5,0 – 10000) μg/l Cadmium (1,0 – 2000) μg/l Lithium (1,0 – 2000) μg/l Manganese (1,0 – 10000) μg/l Copper (1,0 – 2000) μg/l Nickel (1,0 – 2000) μg/l Lead (1,0 – 2000) μg/l Mercury (0,3 – 2,0) μg/l Selenium (1,0 – 2000) μg/l Strontium (1,0 – 2000) μg/ Silver (1,0 – 2000) μg/l Vanadium (1,0 – 2000) μg/l |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN ISO 17294-2:2024-04 | |
| 18 | Water, water intended for human consumption | Colour Range (2 – 100) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 p.6+Ap1:2015 | |
| 19 | Water, water intended for human consumption | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 20 | Water, water intended for human consumption | Turbidity Range (0,20 – 40) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 21 | Water, water intended for human consumption | Iron concentration Range (0,010 – 20,0) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016 | |
| 22 | Water, water intended for human consumption | Total organic carbon concentration (TOC) Range (1,0 – 250) mg/l |
Spectrometry method in the infrared range IR | PN-EN 1484:1999 | |
| 23 | Water, water intended for human consumption | Permanganate index Range (0,5 – 20) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 24 | Water, water intended for human consumption | Concentration of highly volatile halogenated hydrocarbons (THM) chloroform (1,0 – 100) μg/l bromodichloromethane (1,0 – 100) μg/l chlorodibromomethane (1,0 – 100) μg/l bromoform (1,0 – 100) μg/l Sum of 4 THM (calculated) |
Gas chromatography with electron capture detection (GC-ECD) | PB-02(C) wyd. V z dnia 03.02.2020 r. | |
| 25 | Water, water intended for human consumption, wastewater | Metal concentrations Zn (0,05 – 100) mg/l Cu (0,05 – 10) mg/l Ni (0,1 – 15) mg/l Cd (0,03 – 10) mg/l Pb (0,2 – 10) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002 | |
| 26 | Water, water intended for human consumption, wastewater | Concentration of aromatic hydrocarbons benzene (0,001 – 1,75) mg/l toluene (0,001 – 1,75) mg/l ethylbenzene (0,001 – 1,75) mg/l (m+p)-xylene (0,002 – 3,50) mg/l o-xylene (0,001 – 1,75) mg/l Sum of BTEX (calculated) |
Gas chromatography with flame ionization detection (GC-FID) | PB-11(C) wyd. IV z dnia 03.02.2020 r. | |
| 27 | Water, water intended for human consumption, wastewater | Concentration of aliphatic hydrocarbons C7-C12 Range (0,05 – 6,0) mg/l Concentration of aliphatic hydrocarbons C12-C40 Range (0,05 – 6,0) mg/l |
Gas chromatography with flame ionization detection (GC-FID) | PB-12(C) wyd. IV z dnia 01.04.2019 r. | |
| 28 | Water, water intended for human consumption, wastewater, rainwater and snowmelt water | Mineral oil index Range (1,0 – 100) mg/l |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 9377-2:2003 | |
| 29 | Wastewater | Total organic carbon concentration (TOC) Range (1,0 – 400) mg/l |
Spectrometry method in the infrared range IR | PN-EN 1484:1999 | |
| 30 | Wastewater | Iron concentration Range (0,1 – 20,0) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002 | |
| 31 | Wastewater | Anion concentrations Chlorides (0,50 – 200) mg/l Nitrates (0,40 – 20) mg/l Sulfates (1 – 1000) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 32 | Wastewater | Concentration of highly volatile halogenated hydrocarbons trichloromethane (chloroform) Range (0,01 – 4,0) mg/l tetrachloromethane (carbon tetrachloride) (0,01 – 4,0) mg/l |
Gas chromatography with electron capture detection (GC-ECD) | PN-EN ISO 10301:2002 | |
| 33 | Wastewater | Element concentration Arsenic (1,0 – 2000) μg/l Chromium (0,010 – 10,0) mg/l Zinc (0,010 – 20,0) mg/l Cadmium (1,0 – 2000) μg/l Copper (0,010 – 10,0) mg/l Nickel (0,010 – 10,0) mg/l Lead (10,0 – 2000) μg/l Silver (1,0 – 2000) μg/l Vanadium (1,0 – 2000) μg/l Iron (0,010 – 10,0) mg/l |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN ISO 17294-2:2024-04 | |
| 34 | Wastewater, Rainwater and snowmelt water | Sampling for chemical and physical testing Temperature of the collected wastewater sample Range (5,0 – 50,0) °C |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 35 | Wastewater, Rainwater and snowmelt water | Total suspended solids (TSS) Range (2,0 – 5000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 36 | Wastewater | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 37 | Wastewater | Electrical conductivity Range (10 – 100000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 38 | Wastewater | Nitrate nitrogen concentration Range (0,1 – 50,0) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 39 | Wastewater | Total phosphorus concentration Range (0,04 – 300) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 | |
| 40 | Wastewater | Nitrite nitrogen concentration Range (0,006 – 10,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 41 | Wastewater | Chloride concentration Range (5 – 10000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 42 | Wastewater | Chemical oxygen demand – COD-Cr Range (10 – 50000) mg/l O2 |
Titrimetric method | PN-74/C-04578.03 | |
| 43 | Wastewater | Chemical oxygen demand – COD-Cr Range (30 – 50000) mg/l O2 |
Titrimetric method | PN-ISO 6060:2006 | |
| 44 | Wastewater | Chemical oxygen demand – COD-Cr Range (10,0 – 150) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 45 | Wastewater | Biochemical oxygen demand – BOD5, BOD2+5 Range (3 – 6000) mg/l O2 |
Titrimetric method | PN-EN ISO 5815-1:2019-12 | |
| 46 | Wastewater | Biochemical oxygen demand – BOD5, BOD2+5 Range (1,0 – 6,0) mg/l O2 |
Titrimetric method | PN-EN 1899-2:2002 | |
| 47 | Wastewater | Ammonium nitrogen concentration Range (2,0 – 1000) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 48 | Wastewater | Ammonium nitrogen concentration Range (0,040 – 2,00) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 49 | Wastewater | Kjeldahl nitrogen concentration Range (1,0 – 1000) mg/l |
Titrimetric method | PN–EN 25663:2001 | |
| 50 | Wastewater | Total nitrogen concentration (calculated) | PB-07(F) wyd. VI z dnia 01.02.2017 r. | ||
| 51 | Wastewater | Total chromium concentration Range (0,01 – 10) mg/l |
Spectrophotometric method | PN-77/C-04604.02 | |
| 52 | Wastewater | Hexavalent chromium concentration Range (0,01 – 10) mg/l Trivalent chromium concentration (calculated) |
Spectrophotometric method | PN-77/C-04604.08 | |
| 53 | Wastewater | Concentration of substances extractable with petroleum ether Range (20 – 650) mg/l |
Gravimetric method | PB-05(F) wyd. V z dnia 01.02.2017 r. | |
| 54 | Wastewater | Concentration of non-ionic surfactants (non-ionic detergents) Range (0,50 – 60,0) mg/l |
Spectrophotometric method | PB-09(F) wyd. I z dnia 14.02.2017 r. w oparciu o testy HACH LANGE LCK 333 | |
| 55 | Wastewater | Concentration of anionic surfactants (anionic detergents) Range (0,10 – 40,0) mg/l |
Spectrophotometric method | PB-10(F) wyd. I z dnia 14.02.2017 r. w oparciu o testy HACH LANGE LCK 432 | |
| 56 | Water, wastewater | Biochemical oxygen demand – BOD5, BOD2+5 Range (3 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 57 | Water, wastewater | Biochemical oxygen demand – BOD5, BOD2+5 Range (1,0 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 58 | Water, water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.4.2, 4.4.3, 4.4.5, 4.4.6 | ||
| 59 | Water, water intended for human consumption | Total viable count at 36 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 60 | Water, water intended for human consumption | Escherichia coli and coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12+A1:2017-04 | |
| 61 | Water, water intended for human consumption | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 62 | Water, water intended for human consumption | Count of Legionella sp. bacteria Matrix A Procedure 5 (medium A), 7 (medium C-GVPC) from 1 CFU/100 ml from 1CFU/1l |
Membrane filtration method | PN-EN ISO 11731:2017-08+Ap1:2019-12 | |
| 63 | Water, water intended for human consumption | Total viable count at 22 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 64 | Water, water intended for human consumption | Faecal coliform bacteria count | MPN method | PN-77/C-04615.07 | |
| 65 | Water, water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 66 | Water, water intended for human consumption | Clostridium perfringens count including spores | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 67 | Swimming pool water | Count of Legionella sp. bacteria Matrix B Procedure 7 (medium C-GVPC) from 1 CFU/100 ml |
Membrane filtration method | PN-EN ISO 11731:2017-08+Ap1:2019-12 | |
Reference standards (54)
P N - I SO 6059:1999
PB-02(C) wyd. V z dnia 03.02.2020 r.
PB-05(F) wyd. V z dnia 01.02.2017 r.
PB-07(F) wyd. VI z dnia 01.02.2017 r.
PB-09(F) wyd. I z dnia 14.02.2017 r. w oparciu o testy HACH LANGE LCK 333
PB-10(F) wyd. I z dnia 14.02.2017 r. w oparciu o testy HACH LANGE LCK 432
PB-11(C) wyd. IV z dnia 03.02.2020 r.
PB-12(C) wyd. IV z dnia 01.04.2019 r.
PB-15(C) wyd. III z dnia 01.02.2017 r.
PN-74/C-04578.03
PN-77/C-04584
PN-77/C-04604.02
PN-77/C-04604.08
PN-77/C-04615.07
PN-82/C-04576.08
PN-82/C-04576/08
PN-92/C-04590.02
PN-EN 1484:1999
PN-EN 1899-2:2002
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10301:2002
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08+Ap1:2019-12
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 17294-2:2024-04
PN-EN ISO 17852:2009
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.4.2, 4.4.3, 4.4.5, 4.4.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 p.6+Ap1:2015
PN-EN ISO 7899-2:2004
PN-EN ISO 7980:2002
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12+A1:2017-04
PN-EN ISO 9377-2:2003
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 6.5
PN-ISO 6060:2006
PN-ISO 6332:2001+Ap1:2016
PN-ISO 7150-1:2002
PN-ISO 8288:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-ISO 9964-1:1994+Ap1:2009
PN-ISO 9964-2:1994
PN–EN 25663:2001