🇵🇱 PERN S.A. PL

PCA AB 387 • Płock, Poland • 318 methods

Petrochemistry & fuelsWater & wastewaterEnvironmentMaterials & polymers

PERN S.A. is a laboratory accredited by PCA under number AB 387 (Płock, Poland). Its accreditation scope covers 318 test methods in the following areas: Petrochemistry & fuels, Water & wastewater, Environment, Materials & polymers. Test objects include: Liquid fuels E, Crude oil E, Water, wastewater E, Water, wastewater E, Drinking water E. Most frequently used techniques: Gravimetric method, Gas chromatography with flame ionization detection (GC-FID), Optical method.

At a glance

  • Accreditation number: PCA AB 387
  • Methods in scope: 318
  • Types of test objects: 16
  • Techniques used: 45
  • City: Płock, Poland
Accreditation number
AB 387
Accreditation body
PCA
Address
ul. Wyszogrodzka 133, 09-410 Płock
City
Płock, Poland

What this laboratory tests (16)

Analytical techniques used (45)

Laboratory sections (13)

Laboratory locations

Accreditation scope — test methods (318)

No. Test object Methodology / Parameters Technique Reference document
Laboratorium Paliw Płynnych i Ochrony Środowiska w Nowej Wsi Wielkiej, Pracownia Paliw Płynnych
1 Liquid fuels E, Crude oil E Sampling from tanks for chemical and physical testing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 3170
2 Liquid fuels E, Chemical products E: petroleum solvents Density at 15 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Oscillation method PN-EN ISO 12185
3 Liquid fuels E Fractional composition
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Distillation method PN-EN ISO 3405 z wyłączeniem pkt 9
4 Liquid fuels E Copper strip corrosion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Visual method PN-EN ISO 2160
5 Liquid fuels E Volatility index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 228
6 Liquid fuels E Air saturated vapour pressure (ASVP) and vapour pressure DVPE
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Mini Reid method PN-EN 13016-1
7 Liquid fuels E Lead content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame atomic absorption spectrometry (FAAS) PN-EN 237
8 Liquid fuels E Content of hydrocarbon groups and oxygenates
olefins aromatics benzene oxygenates
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 22854
9 Liquid fuels E Total oxygen content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 22854
10 Liquid fuels E Research octane number (RON)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Motor method PN-EN ISO 5164
11 Liquid fuels E Manganese content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Inductively coupled plasma atomic emission spectrometry (ICP OES) PN-EN 16136
12 Liquid fuels E Kinematic viscosity at 20 oC and 40 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Capillary method PN-EN ISO 3104
13 Liquid fuels E Flash point
Pensky-Martens
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Closed cup method PN-EN ISO 2719
14 Liquid fuels E Carbon residue
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 10370
15 Liquid fuels E Residue after incineration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 6245
16 Liquid fuels E Impurity content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 12662-1
17 Liquid fuels E Cold filter plugging point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN 116
18 Liquid fuels E Cetane index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 4264
19 Liquid fuels E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Coulometric titration method PN-EN ISO 12937
20 Liquid fuels E Manganese content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN 16576
21 Liquid fuels E Fatty acid methyl ester content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrometry method in the infrared range (IR) PN-EN 14078
22 Liquid fuels E Cloud point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN ISO 3015
23 Liquid fuels E Cetane number
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Motor method PN-EN ISO 5165
24 Liquid fuels E Lubricity
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
HFRR method PN-EN ISO 12156-1
25 Liquid fuels E Oxidation stability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Conductometric method PN-EN 15751
26 Liquid fuels E Oxidation stability by rapid small scale oxidation test (RSSOT)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Pressure method PN-EN 16091
27 Liquid fuels E Zawartość grup węglowodorów Aromatycznych
monocyclic aromatic hydrocarbons (MAH) diaromatic hydrocarbons (DAH) tri- and polycyclic aromatic hydrocarbons (T+AH)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Liquid chromatography with refractive index detection (HPLC-RID) PN-EN 12916 z wyłączeniem procedury B
28 Liquid fuels E Polycyclic hydrocarbons (POLY-AH) (calculated), Total aromatic hydrocarbon content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 12916 z wyłączeniem procedury B
29 Liquid fuels E Sulfur content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ultraviolet fluorescence method PN-EN ISO 20846
30 Liquid fuels E Pour point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN ISO 3016
31 Liquid fuels E Gross calorific value
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Calorimetric method PN-C-04062
32 Liquid fuels E Net calorific value (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-C-04062
33 Liquid fuels E Solvent Red 19 dye content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-C-04426 z wyłączeniem metod B i C
34 Liquid fuels E Cetane number
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Motor method PN-EN ISO 5165
35 Liquid fuels E Content of the sum of esters and linolenic acid methyl ester
sum of esters linolenic acid methyl ester
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 14103
36 Liquid fuels E Flash point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Equilibrium method in a closed cup PN-EN ISO 3679 z wyłączeniem procedury A
37 Liquid fuels E Copper strip corrosion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Visual method PN-EN ISO 2160
38 Liquid fuels E Acid value
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 14104
39 Liquid fuels E Iodine value
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric titration method PN-EN 14111
40 Liquid fuels E Content of free and total glycerol and of mono-, di- and triacylglycerols
Monoacylglycerols Diacylglycerols Triacylglycerols Free glycerol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 14105
41 Liquid fuels E Total glycerol (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 14105
42 Liquid fuels E Impurity content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 12662-2
43 Liquid fuels E Content of higher alcohols, methanol and volatile impurities
higher alcohols methanol other volatile impurities
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 15721 z wyłączeniem procedury B
44 Liquid fuels E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Coulometric titration method PN-EN 15489
45 Liquid fuels E Copper content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN 15488
Laboratorium Paliw Płynnych i Ochrony Środowiska w Nowej Wsi Wielkiej, Punkt laboratoryjny w Dębogórzu
46 Liquid fuels E Sampling from tanks for chemical and physical testing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 3170
47 Liquid fuels E Density at 15 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Oscillation method PN-EN ISO 12185
48 Liquid fuels E Fractional composition
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Distillation method PN-EN ISO 3405
49 Liquid fuels E Flash point
Pensky-Martens
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Closed cup method PN-EN ISO 2719
50 Liquid fuels E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Coulometric titration method PN-EN ISO 12937
Laboratorium Paliw Płynnych i Ochrony Środowiska w Nowej Wsi Wielkiej, Pracownia Ochrony Środowiska
51 Workplace environment E - air Concentration of harmful dust agents – inhalable fraction:
wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts portland cement natural graphite and synthetic graphite coal (hard, brown) silicon carbide non-fibrous calcium sulfate (VI) (gypsum) calcium magnesium carbonate (dolomite) kaolin amorphous and synthetic silica
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-Z-04507
52 Workplace environment E - air Concentration of harmful dust agents – respirable fraction:
organic dusts of animal and plant origin, excluding wood and flour dusts portland cement natural graphite coal (hard, brown) amorphous and synthetic silica
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-Z-04508
53 Workplace environment E - air Sampling for the assessment of occupational exposure to:
dust agents: inhalable fraction respirable fraction organic substances, inorganic substances: respirable fraction
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Personal dosimetry method PN-Z-04008-7
54 Workplace environment E - air Exposure index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-Z-04008-7
55 Workplace environment E - air Hydrocarbon concentration
Ethyl acetate n-Butyl acetate Acetone Styrene Benzene Toluene Pentane Ethylbenzene Ksylen – mieszanina izomerów:1,2-; 1,3-; 1,4- Octane Hexane Heptane
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) LPB/L02/Ś/22
56 Workplace environment E - air samples collected on sorbent tubes Hydrocarbon content
Ethyl acetate n-Butyl acetate Acetone Styrene Benzene Toluene Pentane Ethylbenzene Ksylen – mieszanina izomerów:1,2-; 1,3-; 1,4- Octane Hexane Heptane
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) LPB/L02/Ś/22
57 Workplace environment E - noise A-weighted equivalent sound level, A-weighted maximum sound level, C-weighted peak sound level
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Direct measurement method PN-N-01307 | PN-EN ISO 9612 z wyłączeniem metody obejmującej strategię 2, 3 - pkt 10,11
58 Workplace environment E - noise Noise exposure level referred to:
an 8-hour daily working time average weekly working time (calculated )
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-N-01307 | PN-EN ISO 9612 z wyłączeniem metody obejmującej strategię 2, 3 - pkt 10,11
59 Workplace environment E - indoor and outdoor electric lighting Illuminance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Direct measurement method LPB/L02/Ś/21
60 Workplace environment E - indoor and outdoor electric lighting Illuminance uniformity (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
LPB/L02/Ś/21
61 Water, wastewater E Settleable solids
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Volumetric method PN-72/C-04559.03 (zakres stały)
62 Water, wastewater E Hydrocarbon concentration
benzene toluene xylene ethylbenzene Sum of BTEX (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) LPB/L02/Ś/07
63 Water, wastewater E Total phosphorus concentration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN ISO 6878
64 Water, wastewater E Dissolved oxygen concentration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 25813
65 Water, wastewater E Biochemical oxygen demand
BOD5
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method; Electrochemical method PN-EN ISO 5815-1
66 Water, wastewater E Biochemical oxygen demand - BOD5
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method; Electrochemical method PN-EN 1899-2
67 Water, wastewater E Total suspended solids (TSS)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 872
68 Water, wastewater E Dissolved oxygen concentration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Electrochemical method PN-EN ISO 5814
69 Water, wastewater E Concentration of aliphatic and aromatic hydrocarbons
C7 – C12 (sum of gasolines) C12 – C35 (suma olei mineralnych) Suma benzyn (C6 – C1 Suma benzyn i olei (C6 – C35) (z obliczeń)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) LPB/L02/Ś/12
70 Water, wastewater E Total nitrogen concentration (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
LPB/L02/Ś/14
71 Water, wastewater E Kjeldahl nitrogen concentration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 25663
72 Water, wastewater E Metal concentrations
nickel copper zinc cadmium lead
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288 metoda A
73 Water, wastewater E Potassium concentration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame atomic absorption spectrometry (FAAS) PN-ISO 9964-2
74 Water, wastewater E Mineral oil index (petroleum hydrocarbons)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2
75 Water, wastewater E Chemical oxygen demand (SP-COD)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-ISO 15705
76 Water, wastewater E Dry residue
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method LPB/L02/Ś/05
77 Water, wastewater E Total dissolved solids concentration (TDS)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 15216
78 Water, wastewater E Concentration of aromatic hydrocarbons
benzene toluene m+p xylene o-xylene ethylbenzene Sum of BTEX (calculated) Ksylen ( z obliczeń)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Headspace gas chromatography with flame ionization detection (HS-GC-FID) PN-ISO 11423-1
79 Water, wastewater Nitrate concentration
Range (1,0 – 120) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
80 Water, wastewater Nitrate nitrogen concentration (calculated) PN-EN ISO 10304-1:2009+AC:2012
81 Water, wastewater Nitrite concentration
Range (0,05 – 3) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
82 Water, wastewater Nitrite nitrogen concentration (calculated) PN-EN ISO 10304-1:2009+AC:2012
83 Water, wastewater Chloride concentration
Range (4 – 1500) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
84 Water, wastewater Sulfate concentration
Range (8 – 500) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
85 Water, wastewater E Element concentration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885
86 Water, wastewater E, Drinking water E Nitrate nitrogen concentration
NNO3 nitrates NO3
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-82/C-04576.08 (zakres stały)
87 Water, wastewater E, Drinking water E Iron concentration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-ISO 6332
88 Water, wastewater E, Drinking water E Nitrite nitrogen concentration
NNO2 nitrites NO2
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN 26777
89 Water, wastewater E, Drinking water E Ammonium nitrogen concentration
NNH4 ammonium ion NH4+ ammonia NH3
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-ISO 7150-1
90 Water, wastewater E, Drinking water E Sulfate concentration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-ISO 9280
91 Water, wastewater E, Drinking water E pH
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric method PN-EN ISO 10523
92 Water, wastewater E, Drinking water E Chloride concentration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-ISO 9297
93 Water, wastewater E, Drinking water E Total concentration of calcium and magnesium (total hardness)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-ISO 6059
94 Water, wastewater E, Drinking water E Sodium concentration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame atomic absorption spectrometry (FAAS) PN-ISO 9964-1
95 Water, wastewater E, Drinking water E Permanganate index
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN ISO 8467
96 Water, wastewater E, Drinking water E Colour
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN ISO 7887
97 Water, wastewater E, Drinking water E Electrical conductivity
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Conductometric method PN-EN 27888
98 Water, wastewater E, Drinking water E Total organic carbon concentration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrometry method in the infrared range (IR) PN-EN 1484
99 Water, wastewater E, Drinking water E Element concentration
lead cadmium chromium nickel manganese
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586
100 Drinking water E Metal concentrations
copper
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288 metoda A
101 Groundwater E Sampling for chemical and physical testing
Temperature of the collected water sample
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Manual method PN-ISO 5667-11 z wyłączeniem pkt 5.2, 6.2, 6.3.2 | PN-77/C-04584 (zakres stały)
102 Wastewater E Sampling for chemical and physical testing
Temperature of the collected wastewater sample
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Manual method; Automatic method PN-ISO 5667-10 | PN-77/C-04584 (zakres stały)
103 Water E, Groundwater E Concentration of polycyclic aromatic hydrocarbons (PAH)
benzo(a)pyrene benzo(b)fluoranthene benzo(k)fluoranthene dibenzo(ah)anthracene benzo(ghi)perylene indeno(1,2,3-cd)pyrene
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-performance liquid chromatography with fluorescence detection HPLC-FLD) PN-EN ISO 17993
104 Water E, Groundwater E Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 17993
105 Soil E Sampling for chemical and physical testing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-ISO 10381-5
106 Soil E Content of soil dry matter and water in soil expressed on soil dry matter basis
dry matter water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-ISO 11465
107 Soil E Volatile aromatic hydrocarbon content
Benzene Toluene m+p xylene o-xylene Ethylbenzene Styrene Ksylen (z obliczeń) Sum of aromatic hydrocarbons (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Metoda chromatografii gazowej z analizą fazy nadpowierzchniowei i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-EN ISO 22155
108 Soil E Content of hydrocarbons C7 – C12:
Content of C6 – C12 hydrocarbons (components of the gasoline fraction) (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) LPB/L02/Ś/02
109 Soil E Content of hydrocarbons C10 – C40 (mineral oil content)
Content of C12 – C35 hydrocarbons (components of the oil fraction) (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 16703
Laboratorium Paliw Płynnych w Koluszkach
110 Liquid fuels E, Crude oil E Sampling from tanks for chemical and physical testing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 3170
111 Liquid fuels E Density at 15 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Oscillation method PN-EN ISO 12185
112 Liquid fuels E Sulfur content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Energy-dispersive X-ray fluorescence spectrometry PN-EN ISO 8754
113 Liquid fuels E Fatty acid methyl ester content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrometry method in the infrared range (IR) PN-EN 14078
114 Liquid fuels E Fractional composition
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Distillation method PN-EN ISO 3405 z wyłączeniem pkt 9
115 Liquid fuels E Cold filter plugging point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN 116
116 Liquid fuels E Lubricity
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
HFRR method PN-EN ISO 12156-1
117 Liquid fuels E Cloud point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN ISO 3015
118 Liquid fuels E Oxidation stability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 12205
119 Liquid fuels E Zawartość grup węglowodorów Aromatycznych
monocyclic aromatic hydrocarbons (MAH) diaromatic hydrocarbons (DAH) tri- and polycyclic aromatic hydrocarbons (T+AH
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Liquid chromatography with refractive index detection (HPLC-RID) PN-EN 12916 z wyłączeniem procedury B
120 Liquid fuels E Polycyclic hydrocarbons (POLY-AH) (calculated), Total aromatic hydrocarbon content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 12916 z wyłączeniem procedury B
121 Liquid fuels E Cetane index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 4264
122 Liquid fuels E Fatty acid methyl ester content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrometry method in the infrared range (IR) PN-EN 14078
123 Liquid fuels E Derived cetane number (DCN)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Combustion chamber method PN-EN 16715
124 Liquid fuels E Impurity content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 12662-1
125 Liquid fuels E Kinematic viscosity at 20 oC and 40 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Capillary method PN-EN ISO 3104
126 Liquid fuels E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Coulometric titration method PN-EN ISO 12937
127 Liquid fuels E Flash point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Pensky-Martens closed cup method PN-EN ISO 2719
128 Liquid fuels E Residue after incineration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 6245
129 Liquid fuels E Carbon residue
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 10370
130 Liquid fuels E Red dye content calculated as Solvent Red 19
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-C-04426 z wyłączeniem metod B i C
131 Liquid fuels E Sulfur content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ultraviolet fluorescence method PN-EN ISO 20846
132 Liquid fuels E Copper strip corrosion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Visual method PN-EN ISO 2160
133 Liquid fuels E Volatility index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 228
134 Liquid fuels E Gum content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 6246
135 Liquid fuels E Air saturated vapour pressure
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Mini Reid method PN-EN 13016-1
136 Liquid fuels E Motor octane number (MON)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Motor method PN-EN ISO 5163
137 Liquid fuels E Oxidation stability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Induction period method PN-EN ISO 7536
138 Liquid fuels E Content of hydrocarbon groups and oxygenates
olefins aromatics benzene oxygenates
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 22854
139 Liquid fuels E Total oxygen content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 22854
140 Liquid fuels E Content of esters and linolenic acid methyl ester
Sum of esters Ester metylowy kwasu linolenowego:
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 14103
141 Liquid fuels E Flash point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Equilibrium method in a closed cup PN-EN ISO 3679 z wyłączeniem procedury A
142 Liquid fuels E Impurity content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 12662-2
143 Liquid fuels E Acid value
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 14104
144 Liquid fuels E Pour point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN ISO 3016
145 Liquid fuels E Oxidation stability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Conductometric method PN-EN 15751
146 Liquid fuels E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Coulometric titration method PN-EN 15489
147 Liquid fuels E Appearance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Visual method PN-EN 15769
Laboratorium Paliw Płynnych w Woli Rzędzińskiej
148 Liquid fuels E Sampling from tanks for chemical and physical testing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 3170
149 Liquid fuels E Density at 15 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Oscillation method PN-EN ISO 12185
150 Liquid fuels E Fractional composition
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Distillation method PN-EN ISO 3405 z wyłączeniem pkt 9
151 Liquid fuels E Flash point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Metoda zamkniętego tygla Pensky’ego–Martensa PN-EN ISO 2719
152 Liquid fuels E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Coulometric titration method PN-EN ISO 12937
153 Liquid fuels E Impurity content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 12662-1
154 Liquid fuels E Kinematic viscosity at 40°C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Capillary method PN-EN ISO 3104
155 Liquid fuels E Cold filter plugging point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN 116
156 Liquid fuels E Cetane index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 4264
157 Liquid fuels E Fatty acid methyl ester content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrometry method in the infrared range (IR) PN-EN 14078
158 Liquid fuels E Copper strip corrosion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Visual method PN-EN ISO 2160
159 Liquid fuels E Sulfur content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ultraviolet fluorescence method PN-EN ISO 20846
160 Liquid fuels E Air saturated vapour pressure
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Mini Reid method PN-EN 13016-1
161 Liquid fuels E Volatility index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 228
162 Liquid fuels E Content of oxygenated organic compounds
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13132
163 Liquid fuels E Total organically bound oxygen content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 13132
164 Liquid fuels E Benzene content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 12177
Laboratorium Paliw Płynnych w Małaszewiczach
165 Liquid fuels E, Crude oil E Sampling from tanks for chemical and physical testing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 3170
166 Liquid fuels E Cetane index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 4264
167 Liquid fuels E Fatty acid methyl ester content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrometry method in the infrared range (IR) PN-EN 14078
168 Liquid fuels E Cloud point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN ISO 3015
169 Liquid fuels E Density at 15 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Oscillation method PN-EN ISO 12185
170 Liquid fuels E Sulfur content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ultraviolet fluorescence method PN-EN ISO 20846
171 Liquid fuels E Fractional composition
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Distillation method PN-EN ISO 3405 z wyłączeniem pkt 9
172 Liquid fuels E Flash point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Pensky - Martens closed cup method PN-EN ISO 2719
173 Liquid fuels E Impurity content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 12662-1
174 Liquid fuels E Kinematic viscosity at 40 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Capillary method PN-EN ISO 3104
175 Liquid fuels E Cold filter plugging point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN 116
176 Liquid fuels E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Coulometric titration method PN-EN ISO 12937
Laboratorium Paliw Płynnych w Emilianowie
177 Liquid fuels E, Crude oil E Sampling from tanks for chemical and physical testing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 3170
178 Liquid fuels E Density at a temperature of 15oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Oscillation method PN-EN ISO 12185
179 Liquid fuels E Sulfur content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ultraviolet fluorescence method PN-EN ISO 20846
180 Liquid fuels E Fractional composition
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Distillation method PN-EN ISO 3405 z wyłączeniem pkt 9
181 Liquid fuels E Kinematic viscosity at 20°C and 40°C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Capillary method PN-EN ISO 3104
182 Liquid fuels E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Coulometric titration method PN-EN ISO 12937 z wyłączeniem pkt 6.2.5 - 6.2.8
183 Liquid fuels E Flash point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Pensky - Martens closed cup method PN-EN ISO 2719
184 Liquid fuels E Carbon residue
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 10370
185 Liquid fuels E Impurity content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 12662-1
186 Liquid fuels E Residue after incineration
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 6245
187 Liquid fuels E Copper strip corrosion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Visual method PN-EN ISO 2160
188 Liquid fuels E Cold filter plugging point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN 116
189 Liquid fuels E Cetane index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 4264
190 Liquid fuels E Content of fatty acid methyl esters
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrometry method in the infrared range (IR) PN-EN 14078
191 Liquid fuels E Cloud point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN ISO 3015
192 Liquid fuels E Oxidation stability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Conductometric method PN-EN 15751
193 Liquid fuels E Oxidation stability by rapid small scale oxidation test (RSSOT)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Pressure method PN-EN 16091
194 Liquid fuels E Pour point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN ISO 3016
195 Liquid fuels E Solvent Red 19 dye content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-C-04426 z wyłączeniem metod B i C
196 Liquid fuels E Air saturated vapour pressure
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Mini Reid method PN-EN 13016-1
197 Liquid fuels E Benzene content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 12177
198 Liquid fuels E Volatility index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 228
199 Liquid fuels E Content of oxygenated organic compounds
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13132
200 Liquid fuels E Total organically bound oxygen content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 13132
201 Liquid fuels E Research octane number (RON)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Motor method PN-EN ISO 5164
202 Liquid fuels E Content of the sum of esters and linolenic acid methyl ester
sum of esters linolenic acid methyl ester
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 14103
203 Liquid fuels E Flash point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Equilibrium method in a closed cup PN-EN ISO 3679
204 Liquid fuels E Oxidation stability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Conductometric method PN-EN 15751
205 Liquid fuels E Impurity content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 12662-2
206 Liquid fuels E Acid value
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 14104
Laboratorium Paliw Płynnych w Kawicach; Kawice, 59-230 Prochowice
207 Liquid fuels E Sampling from tanks for physical and chemical testing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 3170
208 Liquid fuels E Density at 15 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Oscillation method PN-EN ISO 12185
209 Liquid fuels E Fractional composition
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Distillation method PN-EN ISO 3405 z wyłączeniem pkt 9
210 Liquid fuels E Sulfur content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ultraviolet fluorescence method PN-EN ISO 20846
211 Liquid fuels E Cetane index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 4264
212 Liquid fuels E Cold filter plugging point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN 116
213 Liquid fuels E Cloud point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN ISO 3015
214 Liquid fuels E Fatty acid methyl ester content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrometry method in the infrared range (IR) PN-EN 14078
215 Liquid fuels E Oxidation stability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Conductometric method PN-EN 15751
216 Liquid fuels E Impurity content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 12662-1
217 Liquid fuels E Flash point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Pensky-Martens closed cup method PN-EN ISO 2719
218 Liquid fuels E Kinematic viscosity at 20 oC and 40 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Capillary method PN-EN ISO 3104
219 Liquid fuels E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Coulometric titration method PN-EN ISO 12937
220 Liquid fuels E Pour point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-ISO 3016
221 Liquid fuels E Volatility index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 228
222 Liquid fuels E Air saturated vapour pressure
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Mini Reid method PN-EN 13016-1
223 Liquid fuels E Content of oxygenated organic compounds
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13132
224 Liquid fuels E Total organically bound oxygen content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 13132
225 Liquid fuels E Benzene content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 12177
226 Liquid fuels E Density at 15 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Oscillation method PN-EN ISO 12185
227 Liquid fuels E Kinematic viscosity at 40 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Capillary method PN-EN ISO 3104
228 Liquid fuels E Sulfur content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ultraviolet fluorescence method PN-EN ISO 20846
229 Liquid fuels E Cold filter plugging point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN 116
230 Liquid fuels E Oxidation stability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Conductometric method PN-EN 15751
Laboratorium Paliw Płynnych w Rejowcu
231 Liquid fuels E Sampling from tanks and pipelines for chemical and physical testing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 3170
232 Liquid fuels E Density at 15 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Oscillation method PN-EN ISO 12185
233 Liquid fuels E Fractional composition
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Distillation method PN-EN ISO 3405 z wyłączeniem pkt 9
234 Liquid fuels E Sulfur content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ultraviolet fluorescence method PN-EN ISO 20846
235 Liquid fuels E Fatty acid methyl ester content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrometry method in the infrared range (IR) PN-EN 14078
236 Liquid fuels E Cloud point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN ISO 3015
237 Liquid fuels E Cetane index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 4264
238 Liquid fuels E Oxidation stability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Conductometric method PN-EN 15751
239 Liquid fuels E Oxidation stability by rapid small scale oxidation test (RSSOT)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Pressure method PN-EN 16091
240 Liquid fuels E Cold filter plugging point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN 116
241 Liquid fuels E Impurity content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 12662-1
242 Liquid fuels E Kinematic viscosity at 20 oC and 40 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Capillary method PN-EN ISO 3104
243 Liquid fuels E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Coulometric titration method PN-EN ISO 12937
244 Liquid fuels E Flash point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Pensky-Martens closed cup method PN-EN ISO 2719
245 Liquid fuels E Pour point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN ISO 3016
246 Liquid fuels E Copper strip corrosion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Visual method PN-EN ISO 2160
247 Liquid fuels E Oxidation stability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Conductometric method PN-EN 15751
248 Liquid fuels E Impurity content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 12662-2
249 Liquid fuels E Volatility index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 228
250 Liquid fuels E Air saturated vapour pressure
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Mini Reid method PN-EN 13016-1
251 Liquid fuels E Benzene content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 12177
252 Liquid fuels E Content of hydrocarbon groups and oxygenates
olefins aromatics benzene oxygenates
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 22854
253 Liquid fuels E Total oxygen content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 22854
Laboratorium Paliw Płynnych w Boronowie
254 Liquid fuels E Sampling from tanks for chemical and physical testing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 3170
255 Liquid fuels E Density at 15 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Oscillation method PN-EN ISO 12185
256 Liquid fuels E Density at a temperature of 20 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Oscillation method PN-EN ISO 12185
257 Liquid fuels E Fractional composition
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Distillation method PN-EN ISO 3405 z wyłączeniem pkt 9
258 Liquid fuels E Sulfur content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ultraviolet fluorescence method PN-EN ISO 20846
259 Liquid fuels E Cold filter plugging point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN 116
260 Liquid fuels E Cloud point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN ISO 3015
261 Liquid fuels E Fatty acid methyl ester content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrometry method in the infrared range (IR) PN-EN 14078
262 Liquid fuels E Cetane index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 4264
263 Liquid fuels E Cloud point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN ISO 3015
264 Liquid fuels E Oxidation stability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Conductometric method PN-EN 15751
265 Liquid fuels E Kinematic viscosity at 20 oC and 40 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Capillary method PN-EN ISO 3104
266 Liquid fuels E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Coulometric titration method PN-EN ISO 12937
267 Liquid fuels E Flash point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Pensky-Martens closed cup method PN-EN ISO 2719
268 Liquid fuels E Impurity content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 12662-1
269 Liquid fuels E Carbon residue
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 10370
270 Liquid fuels E Corrosive action action on copper
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Visual method PN-EN ISO 2160
271 Liquid fuels E Pour point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method PN-EN ISO 3016
272 Liquid fuels E Dye content, Solvent Red 19
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-C-04426 z wyłączeniem metod B i C
273 Liquid fuels E Volatility index (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 228
274 Liquid fuels E Air saturated vapour pressure
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Mini Reid method PN-EN 13016-1
275 Liquid fuels E Research octane number (RON)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Motor method PN-EN ISO 5164
276 Liquid fuels E Motor octane number (MON)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Motor method PN-EN ISO 5163
277 Liquid fuels E Content of hydrocarbon groups and oxygenates
olefins aromatics benzene oxygenates
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 22854
278 Liquid fuels E Total oxygen content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 22854
279 Liquid fuels E Acid value
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 14104
280 Liquid fuels E Iodine value
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 14111
281 Liquid fuels E Content of the sum of esters and linolenic acid methyl ester
sum of esters linolenic acid methyl ester
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 14103
282 Liquid fuels E Oxidation stability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Conductometric method PN-EN 15751
283 Liquid fuels E Flash point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Equilibrium method in a closed cup PN-EN ISO 3679 z wyłączeniem procedury A
284 Liquid fuels E Impurity content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 12662-2
285 Liquid fuels E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Coulometric titration method PN-EN 15489
286 Liquid fuels E Appearance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Visual method PN-EN 15769
Laboratorium Ropy w Adamowie; Adamowo, 17-307 Mielnik
287 Crude oil E Density at 15 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Oscillation method ASTM D5002
288 Crude oil E Sampling from tanks for chemical and physical testing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 3170
289 Crude oil E Sampling from pipelines for chemical and physical testing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
GOST2517 Z wyłączeniem punktu: 4.1-4.12; 4.13.3-4.15
290 Crude oil E Chloride salt content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Conductometric method ASTM D3230
291 Crude oil E Sulfur content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Energy-dispersive X-ray fluorescence spectrometry ASTM D4294 | GOST R 51947
292 Crude oil E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric titration method ASTM D 4377
293 Crude oil E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Distillation method GOST 2477
294 Crude oil E Organic chloride content in the fraction boiling up to 204 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Microcoulometric method ASTM D4929 metoda B | GOST R 52247 metoda B
295 Crude oil E Organic chloride content in crude oil (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
ASTM D4929 metoda B | GOST R 52247 metoda B
296 Crude oil E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Coulometric titration method ASTM D4928
297 Crude oil E Impurity content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method GOST 6370
298 Crude oil E Chloride salt content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method GOST 21534
Laboratorium Ropy w Miszewku Strzałkowskim; Miszewko Strzałkowskie, 09-472 Słupno
299 Crude oil E Density at 15 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Oscillation method ASTM D5002
300 Crude oil E Sampling from tanks for chemical and physical testing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 3170
301 Crude oil E Sulfur content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Energy-dispersive X-ray fluorescence spectrometry ASTM D4294
302 Crude oil E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric titration method ASTM D 4377
303 Crude oil E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Distillation method GOST 2477
304 Crude oil E Organic chloride content in the fraction boiling up to 204 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Microcoulometric method ASTM D4929 metoda B | GOST R 52247 metoda B
305 Crude oil E Organic chloride content in crude oil (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
ASTM D4929 metoda B | GOST R 52247 metoda B
306 Crude oil E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Coulometric titration method ASTM D4928
307 Crude oil E Chloride salt content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Conductometric method ASTM D3230
308 Crude oil E Chloride salt content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
ASTM D3230
309 Crude oil E Impurity content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method ASTM D473
Laboratorium Ropy w Gdańsku
310 Crude oil E Sampling from tanks for chemical and physical testing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 3170
311 Crude oil E Density at 15 oC
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Oscillation method ASTM D5002
312 Crude oil E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric method ASTM D4377
313 Crude oil E Sulfur content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Energy-dispersive X-ray fluorescence spectrometry ASTM D4294
314 Crude oil E Sediment content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method ASTM D473
315 Crude oil E Chloride salt content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Conductometric method ASTM D3230
316 Crude oil E Chloride salt content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
ASTM D3230
317 Crude oil E Pour point
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Optical method ASTM D 5853 Procedura A
318 Crude oil E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Coulometric titration method ASTM D4928

Reference standards (117)

ASTM D 4377
ASTM D 5853 Procedura A
ASTM D3230
ASTM D4294
ASTM D4377
ASTM D473
ASTM D4928
ASTM D4929 metoda B
ASTM D5002
GOST 21534
GOST 2477
GOST 6370
GOST R 51947
GOST R 52247 metoda B
GOST2517 Z wyłączeniem punktu: 4.1-4.12; 4.13.3-4.15
LPB/L02/Ś/02
LPB/L02/Ś/05
LPB/L02/Ś/07
LPB/L02/Ś/12
LPB/L02/Ś/14
LPB/L02/Ś/21
LPB/L02/Ś/22
PN-72/C-04559.03 (zakres stały)
PN-77/C-04584 (zakres stały)
PN-82/C-04576.08 (zakres stały)
PN-C-04062
PN-C-04426 z wyłączeniem metod B i C
PN-EN 116
PN-EN 12177
PN-EN 12662-1
PN-EN 12662-2
PN-EN 12916 z wyłączeniem procedury B
PN-EN 13016-1
PN-EN 13132
PN-EN 14078
PN-EN 14103
PN-EN 14104
PN-EN 14105
PN-EN 14111
PN-EN 1484
PN-EN 15216
PN-EN 15488
PN-EN 15489
PN-EN 15721 z wyłączeniem procedury B
PN-EN 15751
PN-EN 15769
PN-EN 16091
PN-EN 16136
PN-EN 16576
PN-EN 16715
PN-EN 1899-2
PN-EN 228
PN-EN 237
PN-EN 25663
PN-EN 25813
PN-EN 26777
PN-EN 27888
PN-EN 872
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10370
PN-EN ISO 10523
PN-EN ISO 11885
PN-EN ISO 12156-1
PN-EN ISO 12185
PN-EN ISO 12205
PN-EN ISO 12937
PN-EN ISO 12937 z wyłączeniem pkt 6.2.5 - 6.2.8
PN-EN ISO 15586
PN-EN ISO 16703
PN-EN ISO 17993
PN-EN ISO 20846
PN-EN ISO 2160
PN-EN ISO 22155
PN-EN ISO 22854
PN-EN ISO 2719
PN-EN ISO 3015
PN-EN ISO 3016
PN-EN ISO 3104
PN-EN ISO 3170
PN-EN ISO 3405
PN-EN ISO 3405 z wyłączeniem pkt 9
PN-EN ISO 3679
PN-EN ISO 3679 z wyłączeniem procedury A
PN-EN ISO 4264
PN-EN ISO 5163
PN-EN ISO 5164
PN-EN ISO 5165
PN-EN ISO 5814
PN-EN ISO 5815-1
PN-EN ISO 6245
PN-EN ISO 6246
PN-EN ISO 6878
PN-EN ISO 7536
PN-EN ISO 7887
PN-EN ISO 8467
PN-EN ISO 8754
PN-EN ISO 9377-2
PN-EN ISO 9612 z wyłączeniem metody obejmującej strategię 2, 3 - pkt 10,11
PN-ISO 10381-5
PN-ISO 11423-1
PN-ISO 11465
PN-ISO 15705
PN-ISO 3016
PN-ISO 5667-10
PN-ISO 5667-11 z wyłączeniem pkt 5.2, 6.2, 6.3.2
PN-ISO 6059
PN-ISO 6332
PN-ISO 7150-1
PN-ISO 8288 metoda A
PN-ISO 9280
PN-ISO 9297
PN-ISO 9964-1
PN-ISO 9964-2
PN-N-01307
PN-Z-04008-7
PN-Z-04507
PN-Z-04508