🇵🇱 WOJSKOWY INSTYTUT CHEMII I RADIOMETRII PL
Materials & polymersPetrochemistry & fuels
WOJSKOWY INSTYTUT CHEMII I RADIOMETRII is a laboratory accredited by PCA under number AB 380 (Warszawa, Poland). Its accreditation scope covers 23 test methods in the following areas: Materials & polymers, Petrochemistry & fuels. Test objects include: Gas masks, Filtering half masks, Combined filters for gas masks, Filter materials, filters. Most frequently used techniques: Photometric method, Pressure method, Method: gravimetric.
At a glance
- Accreditation number: PCA AB 380
- Methods in scope: 23
- Types of test objects: 10
- Techniques used: 3
- City: Warszawa, Poland
- Accreditation number
- AB 380
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAWCZE OCHRONY DRÓG ODDECHOWYCH, Al. Gen. A. Chruściela „Montera” 105, 00-910 Warszawa
- City
- Warszawa, Poland
What this laboratory tests (10)
- Gas masks — 5 methods
- Filtering half masks — 4 methods
- Combined filters for gas masks — 3 methods
- Filter materials, filters — 3 methods
- Combined filters — 2 methods
- Masks — 2 methods
- Gas filters and combined filters — 1 method
- Gas filters, Combined filters — 1 method
- Half masks and quarter masks — 1 method
- Sorbent materials — 1 method
Analytical techniques used (3)
- Photometric method — 11 methods
- Pressure method — 9 methods
- Method: gravimetric — 1 method
Accreditation scope — test methods (23)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Sorbent materials | Breakthrough time and sorption capacity with respect to: chlorine, hydrogen sulphide, sulfur dioxide, ammonia, chloropicrin, cyanogen chloride, hydrogen cyanide, cyclohexane. Breakthrough time range: above 5 minutes |
NO-42-A210:2004/A1:2014 p.3.3.5 | ||
| 2 | Gas filters, Combined filters | Breakthrough time and sorption capacity with respect to: chlorine, hydrogen sulphide, sulfur dioxide, ammonia, chloropicrin, cyanogen chloride, hydrogen cyanide, cyclohexane. Breakthrough time range: above 5 minutes |
PN-EN 14387:2021-07 p. 5.12.1, 5.12.2, 6.6 NO-42-A205:2009 p.3.2.4 NO-42-A205:2009/A1:2025 | ||
| 3 | Masks | Breathing resistance (continuous flow) Range (0 ÷ 2000) Pa |
Pressure method | PN-EN 136:2001 p. 8.15 | PN-EN 136:2001/Ap1:2003 | PN-EN 136:2001/AC:2004 | |
| 4 | Half masks and quarter masks | Breathing resistance (continuous flow) Range (0 ÷ 2000) Pa |
Pressure method | PN-EN 140:2001 p. 7.12 | PN-EN 140:2001/Ap1:2003 | |
| 5 | Filtering half masks | Breathing resistance (continuous flow) Range (0 ÷ 2000) Pa |
Pressure method | PN-EN 149+A1:2010 p. 8.9 | |
| 6 | Gas masks | Breathing resistance (continuous flow) Range (0 ÷ 2000) Pa |
Pressure method | NO-42-A214:2017 p. 5.16 | PN-EN 13274-3:2005 p. 6 | |
| 7 | Filter materials, filters | Breathing resistance (continuous flow) Range (0 ÷ 2000) Pa |
Pressure method | PN-EN 143:2021-07 p. 6.11 | |
| 8 | Gas filters and combined filters | Breathing resistance (continuous flow) Range (0 ÷ 2000) Pa |
Pressure method | PN-EN 14387:2021-07 p. 5.11 | PN-EN 13274-3:2005 p. 6 | |
| 9 | Combined filters for gas masks | Breathing resistance (continuous flow) Range (0 ÷ 2000) Pa |
Pressure method | NO-42-A205:2009 p. 2.5 NO-42-A205:2009/A1:2025 | PN-EN 14387:2021-07 p. 5.11 | |
| 10 | Filter materials, filters | Sodium chloride aerosol penetration Range (0,00005 ÷ 100) % |
Photometric method | PN-EN 143:2021-07 p. 6.12 | |
| 11 | Combined filters | Sodium chloride aerosol penetration Range (0,00005 ÷ 100) % |
Photometric method | PN-EN 14387:2021-07 p. 5.13.2 | PN-EN 143:2021-07 p. 6.12 | |
| 12 | Filtering half masks | Sodium chloride aerosol penetration Range (0,00005 ÷ 100) % |
Photometric method | PN-EN 149+A1:2010 p. 8.11 | PN-EN 13274-7:2019-07 p. 6 | |
| 13 | Combined filters for gas masks | Sodium chloride aerosol penetration Range (0,00005 ÷ 100) % |
Photometric method | NO-42-A205:2009 p. 2.6 NO-42-A205:2009/A1:2025 | PN-EN 143:2021-07 p. 6.12 | |
| 14 | Filter materials, filters | Paraffin oil mist aerosol penetration Range (0,0005 ÷ 100) % |
Photometric method | PN-EN 143:2021-07 p.6.12 | |
| 15 | Combined filters | Paraffin oil mist aerosol penetration Range (0,0005 ÷ 100) % |
Photometric method | PN-EN 14387:2021-07 p. 5.13.2 | PN-EN 143:2021-07 p.6.12 | |
| 16 | Filtering half masks | Paraffin oil mist aerosol penetration Range (0,0005 ÷ 100) % |
Photometric method | PN-EN 149+A1:2010 p. 8.11 | PN-EN 13274-7:2019-07 p. 7 | |
| 17 | Combined filters for gas masks | Paraffin oil mist aerosol penetration Range (0,0005 ÷ 100) % |
Photometric method | NO-42-A205:2009 p. 2.6 NO-42-A205:2009/A1:2025 | PN-EN 143:2021-07 p. 6.12 | |
| 18 | Masks | Total inward leakage Range (0,0001÷100)% |
Photometric method | PN-EN 136:2001 p. 8.16 | PN-EN 136:2001/Ap1:2003 | PN-EN 136:2001/AC:2004 | |
| 19 | Filtering half masks | Total inward leakage Range (0,0001÷100)% |
Photometric method | PN-EN 149+A1:2010 p. 8.5 | |
| 20 | Gas masks | Total inward leakage Range (0,0001÷100)% |
Photometric method | NO-42-A214:2017 p. 5.15 | PN-EN 136:2001 p. 8.16 | PN-EN 136:2001/Ap1:2003 | PN-EN 136:2001/AC:2004 | |
| 21 | Gas masks | Mask tightness under static conditions | Pressure method | PN-EN 136:2001 p. 8.13 | PN-EN 136:2001/Ap1:2003 | PN-EN 136:2001/AC:2004 NO-42-A214:2017 p. 5.11 | |
| 22 | Gas masks | Mask tightness under static conditions with the connected UPP (liquid intake device) | Pressure method | NO-42-A214:2017 p. 5.12 | |
| 23 | Gas masks | Mass of the gas mask Range (0 ÷ 3000) g |
Method: gravimetric | NO-42-A214:2017 p. 5.10 | |
Reference standards (27)
NO-42-A205:2009 p. 2.5 NO-42-A205:2009/A1:2025
NO-42-A205:2009 p. 2.6 NO-42-A205:2009/A1:2025
NO-42-A210:2004/A1:2014 p.3.3.5
NO-42-A214:2017 p. 5.10
NO-42-A214:2017 p. 5.12
NO-42-A214:2017 p. 5.15
NO-42-A214:2017 p. 5.16
PN-EN 13274-3:2005 p. 6
PN-EN 13274-7:2019-07 p. 6
PN-EN 13274-7:2019-07 p. 7
PN-EN 136:2001 p. 8.13
PN-EN 136:2001 p. 8.15
PN-EN 136:2001 p. 8.16
PN-EN 136:2001/AC:2004
PN-EN 136:2001/AC:2004 NO-42-A214:2017 p. 5.11
PN-EN 136:2001/Ap1:2003
PN-EN 140:2001 p. 7.12
PN-EN 140:2001/Ap1:2003
PN-EN 14387:2021-07 p. 5.11
PN-EN 14387:2021-07 p. 5.12.1, 5.12.2, 6.6 NO-42-A205:2009 p.3.2.4 NO-42-A205:2009/A1:2025
PN-EN 14387:2021-07 p. 5.13.2
PN-EN 143:2021-07 p. 6.11
PN-EN 143:2021-07 p. 6.12
PN-EN 143:2021-07 p.6.12
PN-EN 149+A1:2010 p. 8.11
PN-EN 149+A1:2010 p. 8.5
PN-EN 149+A1:2010 p. 8.9