🇵🇱 OŚRODEK BADAŃ I ANALIZ PP PL
EnvironmentElectronics & EMC
OŚRODEK BADAŃ I ANALIZ PP is a laboratory accredited by PCA under number AB 286 (Kraków, Poland). Its accreditation scope covers 50 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Workplace environment - non-laser optical radiation, Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment - electromagnetic field from transmitting dev…, Workplace environment − electromagnetic field. Most frequently used techniques: Direct measurement method, Direct measurement method (method A), Direct measurement method (method D).
At a glance
- Accreditation number: PCA AB 286
- Methods in scope: 50
- Types of test objects: 25
- Techniques used: 9
- City: Kraków, Poland
- Accreditation number
- AB 286
- Accreditation body
- PCA
- Address
- Spółka z ograniczoną odpowiedzialnością, ul. Profesora Michała Bobrzyńskiego 23A lok.U2, 30-348 Kraków
- City
- Kraków, Poland
What this laboratory tests (25)
- Workplace environment - non-laser optical radiation — 11 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements — 4 methods
- Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems - radio, television, mobile telephony base stations, etc.) — 3 methods
- Workplace environment − electromagnetic field — 3 methods
- Environment – electromagnetic field in the vicinity of power installations — 2 methods
- General environment - noise from installations, equipment and industrial plants — 2 methods
- General environment – noise from high-voltage power lines — 2 methods
- Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry — 2 methods
- Workplace environment - noise — 2 methods
- Workplace environment − hand-arm vibration — 2 methods
- Workplace environment − whole-body vibration — 2 methods
- Workstations equipped with devices emitting laser radiation — 2 methods
- Dental equipment – panoramic radiography and digital cephalometry units — 1 method
- Environment – electromagnetic field in the vicinity of radiocommunication installations: - selective measurements — 1 method
- Equipment used in computed tomography — 1 method
- and 10 more
Analytical techniques used (9)
- Direct measurement method — 18 methods
- Direct measurement method (method A) — 2 methods
- Direct measurement method (method D) — 1 method
- Direct measurement method (method M) — 1 method
- Direct measurement method (method O) — 1 method
- Direct measurement method (method R) — 1 method
- Direct measurement method (method U) — 1 method
- Direct measurement method (method X) — 1 method
- Direct measurement method; Direct measurement method — 1 method
Accreditation scope — test methods (50)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Electric field strength: in the frequency range 50 Hz Range (100 - 50 000) V/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150 | |
| 2 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Magnetic flux density 50 Hz Range (0,05 - 19 000) μT Magnetic field strength (calculated). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150 | |
| 3 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices | Electric field strength in the frequency range from 100 Hz to 1000 Hz Range (0,9 - 49000) V/m Magnetic flux density in the frequency range from 10 do 1000 Hz Range (0,04 - 19 000) μT Magnetic field strength in the frequency range from 10 do 1000 Hz (calculated) |
Direct measurement method; Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 | |
| 4 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems - radio, television, mobile telephony base stations, etc.) | Electric field strength: in the frequency range from 100 kHz do 3 GHz Range (0,5 - 1250) V/m from 80 MHz do 90 GHz Range (0,5 - 300) V/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131 | |
| 5 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems - radio, television, mobile telephony base stations, etc.) | Magnetic field strength in the frequency range from 300 kHz do 1 GHz Range (0,01 - 190) A/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131 | |
| 6 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems - radio, television, mobile telephony base stations, etc.) | Magnetic field strength in the frequency range from 800 MHz do 90 GHz (calculated) |
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131 | ||
| 7 | Workplace environment − electromagnetic field | Electric field strength in the frequency band: from 5 Hz to 600 kHz Range (0,5 - 30 000) V/m from 100 kHz do 3 GHz Range (0,5 - 1250) V/m from 80 MHz do 90 GHz Range (0,5 - 300) V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | |
| 8 | Workplace environment − electromagnetic field | Magnetic field strength in the frequency band from 0 Hz Range (0,1 - 900) mT from 10 Hz do 600 Hz Range (0,05 - 19000) μT from 300 kHz do 1 GHz Range (0,01 - 12) A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | |
| 9 | Workplace environment − electromagnetic field | Magnetic field strength in the frequency band: from 800 MHz to 90 GHz (calculated) | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | ||
| 10 | Environment – electromagnetic field in the vicinity of power installations | Electric field strength: in the frequency range from 50 Hz Range (100 – 50 000) V/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | |
| 11 | Environment – electromagnetic field in the vicinity of power installations | Magnetic flux density in the frequency range 50 Hz Range (0,05 - 19 000) μT Magnetic field strength (calculated). |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | |
| 12 | Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements | Electric field strength: in the frequency range from 100 kHz do 3 GHz Range (0,5 - 1250) V/m in the frequency range from 80 MHz do 90 GHz Range (0,5 - 300) V/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | |
| 13 | Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements | Magnetic field strength: in the frequency range from 300 kHz do 1 GHz Range (0,01 - 12,0) A/m |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | |
| 14 | Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements | Magnetic field strength in the frequency band: from 300 MHz to 90 GHz (calculated) | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | ||
| 15 | Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements | Power density in the frequency band: from 300 MHz – 3 GHz (calculated) | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | ||
| 16 | Environment – electromagnetic field in the vicinity of radiocommunication installations: - selective measurements | Electric field strength: in the frequency range from 420 MHz do 6 GHz Range (0,01 - 200) V/m Magnetic field strength in the frequency band: from 420 MHz do 6 GHz (calculated) |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | |
| 17 | Workplace environment - noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (43 - 115) dB C-weighted peak sound pressure level Range (43 - 137) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11 | |
| 18 | Workplace environment - noise | Noise exposure level referred to: 8-h daily working time -average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11 | ||
| 19 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (24 - 137) dB |
Direct measurement method | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) – z wyłączeniem pkt. E.II.1 i F | |
| 20 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound level for the reference time T expressed by the index LAeqD and LAeqN (calculated) | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) – z wyłączeniem pkt. E.II.1 i F | ||
| 21 | Workplace environment − whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,02 - 17,8) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 22 | Workplace environment − whole-body vibration | Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy , awz), Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy , awz ) (calculated) | PN-EN 14253+A1:2011 | ||
| 23 | Workplace environment − hand-arm vibration | Weighted r.m.s. values frequency-weighted acceleration vibration Range (0,06 - 100) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 24 | Workplace environment − hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for an 8-hour working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (awx, awy, awz), Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (awx, awy, awz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 25 | General environment – noise from high-voltage power lines | A-weighted equivalent sound pressure level Range (24,0 – 137,0) dB |
Direct measurement method | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023, poz. 1706) – z wyłączeniem pkt. E.II.1 i F | PN-N 01339:2000 | |
| 26 | General environment – noise from high-voltage power lines | A-weighted equivalent sound level for the reference time T expressed by the indicators LAeqD and L AAeqN, Long-term equivalent A-weighted sound level expressed by the indicators, LAeq,LTd and LAeq,LTn (calculated) | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023, poz. 1706) – z wyłączeniem pkt. E.II.1 i F | PN-N 01339:2000 | ||
| 27 | Workplace environment - non-laser optical radiation | Effective irradiance of hazardous ultraviolet in the spectral range 180 - 400 nm, Measurement range: 8*10 -4 - 10 [W/m2] | Direct measurement method (method A) | PN-EN 14255-1:2010 | |
| 28 | Workplace environment - non-laser optical radiation | Effective irradiation of hazardous ultraviolet in the spectral range 180 - 400 nm (calculated) | PN-EN 14255-1:2010 | ||
| 29 | Workplace environment - non-laser optical radiation | Irradiance of UVA radiation in the spectral range 315 - 390 nm, Measurement range: 2*10 -4 - 2*103 [W/m2] | Direct measurement method (method M) | PN-EN 14255-1:2010 | |
| 30 | Workplace environment - non-laser optical radiation | Radiant exposure of UVA radiation in the spectral range 315 - 390 nm (calculated) | PN-EN 14255-1:2010 | ||
| 31 | Workplace environment - non-laser optical radiation | Effective irradiance in the spectral range 305 - 700 nm, Measurement range: 2*10-4 - 3*103 [W/m2] | Direct measurement method (method O) | PN-EN 14255-2:2010 | |
| 32 | Workplace environment - non-laser optical radiation | Irradiance in the spectral range 770 - 3000 nm, Measurement range: 9*10-1 - 4*103 [W/m2] | Direct measurement method (method R) | PN-EN 14255-2:2010 | |
| 33 | Workplace environment - non-laser optical radiation | Effective radiance of visible radiation in the spectral range 305 - 700 nm, Measurement range: 1,4*10-3 - 2,78*104 [W/m2*sr] | Direct measurement method (method D) | PN-EN 14255-2:2010 | |
| 34 | Workplace environment - non-laser optical radiation | Effective radiance of radiation in the spectral range 380 - 1400 nm, Measurement range: 2*10-3 - 2*106 [W/m2*sr] | Direct measurement method (method A) | PN-EN 14255-2:2010 | |
| 35 | Workplace environment - non-laser optical radiation | Effective radiance of radiation in the spectral range 780 - 1400 nm, Measurement range: 2,75*10-3 - 2,75*106 [W/m2*sr] | Direct measurement method (method U) | PN-EN 14255-2:2010 | |
| 36 | Workplace environment - non-laser optical radiation | Irradiance in the spectral range 380 - 3000 nm, Measurement range: 9*10-1 - 4*103 [W/m2] | Direct measurement method (method X) | PN-EN 14255-2:2010 | |
| 37 | Workplace environment - non-laser optical radiation | Radiant exposure of radiation in the spectral range 380 - 3000 nm (calculated) | PN-EN 14255-2:2010 | ||
| 38 | Workstations equipped with devices emitting laser radiation | Power of laser radiation generated by laser devices Range of laser radiation wavelengths: 0,19 - 10,6 [μm] Range of radiation power laser 100 μW - 700 W |
Direct measurement method | PN-EN ISO 11554:2010 | PN-EN ISO 11554:2018-01 | |
| 39 | Workstations equipped with devices emitting laser radiation | Laser pulse energy: Measuring range: − 20 nJ – 20 μJ in the radiation wavelength range λ = (0,19 – 1,1) μm, − 8 μJ – 10 J in the radiation wavelength range λ = (0,15 – 3,0) μm, − 1 mJ – 30 J in the radiation wavelength range λ = (0,19 – 10,6) μm, − 120 mJ – 300 J in the radiation wavelength range λ = (0,19 – 10,6) μm, | Direct measurement method | PN-EN ISO 11554:2010 | PN-EN ISO 11554:2018-01 | |
| 40 | Equipment used in general analogue radiography | Specialist tests | Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/1.8 z dnia 18.05.2018 r. | ||
| 41 | Equipment used in general digital radiography | Specialist tests | Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/1.8 z dnia 18.05.2018 r. | ||
| 42 | Dental equipment – panoramic radiography and digital cephalometry units | Specialist tests | Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/3.6 z dnia 18.05.2018 r. | ||
| 43 | Equipment used in dentistry – units for intra oral radiography | Specialist tests | Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/2.7 z dnia 18.05.2018 r. | ||
| 44 | Equipment used in dental cone beam computed tomography | Specialist tests | Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/3.6 z dnia 18.05.2018 r. Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/3.6 z dnia 18.05.2018 r. | ||
| 45 | Equipment used in fluoroscopy and angiography | Specialist tests | Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/5.9 z dnia 17.03.2025 r. | ||
| 46 | Equipment used in digital mammography | Specialist tests | Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/4.8 z dnia 26.06.2023 r. | ||
| 47 | Equipment used in computed tomography | Specialist tests | Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/8.3 z dnia 18.05.2018 r. | ||
| 48 | Monitors used for the display of medical images | Specialist tests | Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/9.4 z dnia 18.05.2018 r. | ||
| 49 | Workplace environment – ionising radiation | Dose rate in the vicinity of the X-ray apparatus Range 10 nSv/h – 100 mSv/h Direct measurement |
PB/J/6.4 z dnia 20.05.2021 r. | ||
| 50 | General environment – ionising radiation | Dose rate in the vicinity of the X-ray apparatus Range 10 nSv/h – 100 mSv/h Direct measurement |
PB/J/6.4 z dnia 20.05.2021 r. | ||
Reference standards (27)
PB/J/6.4 z dnia 20.05.2021 r.
PN-EN 14253+A1:2011
PN-EN 14255-1:2010
PN-EN 14255-2:2010
PN-EN ISO 11554:2010
PN-EN ISO 11554:2018-01
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11
PN-N 01339:2000
PN-N-01307:1994
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/2.7 z dnia 18.05.2018 r.
Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/3.6 z dnia 18.05.2018 r. Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/3.6 z dnia 18.05.2018 r.
Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/5.9 z dnia 17.03.2025 r.
Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/8.3 z dnia 18.05.2018 r.
Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/1.8 z dnia 18.05.2018 r.
Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/3.6 z dnia 18.05.2018 r.
Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/4.8 z dnia 26.06.2023 r.
Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/9.4 z dnia 18.05.2018 r.
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) – z wyłączeniem pkt. E.II.1 i F
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023, poz. 1706) – z wyłączeniem pkt. E.II.1 i F