🇵🇱 OŚRODEK BADAŃ I ANALIZ PP PL

PCA AB 286 • Kraków, Poland • 50 methods

EnvironmentElectronics & EMC

OŚRODEK BADAŃ I ANALIZ PP is a laboratory accredited by PCA under number AB 286 (Kraków, Poland). Its accreditation scope covers 50 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Workplace environment - non-laser optical radiation, Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment - electromagnetic field from transmitting dev…, Workplace environment − electromagnetic field. Most frequently used techniques: Direct measurement method, Direct measurement method (method A), Direct measurement method (method D).

At a glance

  • Accreditation number: PCA AB 286
  • Methods in scope: 50
  • Types of test objects: 25
  • Techniques used: 9
  • City: Kraków, Poland
Accreditation number
AB 286
Accreditation body
PCA
Address
Spółka z ograniczoną odpowiedzialnością, ul. Profesora Michała Bobrzyńskiego 23A lok.U2, 30-348 Kraków
City
Kraków, Poland

What this laboratory tests (25)

Analytical techniques used (9)

Accreditation scope — test methods (50)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry Electric field strength:
in the frequency range 50 Hz Range (100 - 50 000) V/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150
2 Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry Magnetic flux density 50 Hz
Range (0,05 - 19 000) μT Magnetic field strength (calculated).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150
3 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Electric field strength in the frequency range from 100 Hz to 1000 Hz
Range (0,9 - 49000) V/m Magnetic flux density in the frequency range from 10 do 1000 Hz Range (0,04 - 19 000) μT Magnetic field strength in the frequency range from 10 do 1000 Hz (calculated)
Direct measurement method; Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
4 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems - radio, television, mobile telephony base stations, etc.) Electric field strength:
in the frequency range from 100 kHz do 3 GHz Range (0,5 - 1250) V/m from 80 MHz do 90 GHz Range (0,5 - 300) V/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
5 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems - radio, television, mobile telephony base stations, etc.) Magnetic field strength
in the frequency range from 300 kHz do 1 GHz Range (0,01 - 190) A/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
6 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems - radio, television, mobile telephony base stations, etc.) Magnetic field strength
in the frequency range from 800 MHz do 90 GHz (calculated)
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
7 Workplace environment − electromagnetic field Electric field strength in the frequency band: from 5 Hz to 600 kHz
Range (0,5 - 30 000) V/m from 100 kHz do 3 GHz Range (0,5 - 1250) V/m from 80 MHz do 90 GHz Range (0,5 - 300) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
8 Workplace environment − electromagnetic field Magnetic field strength in the frequency band from 0 Hz
Range (0,1 - 900) mT from 10 Hz do 600 Hz Range (0,05 - 19000) μT from 300 kHz do 1 GHz Range (0,01 - 12) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
9 Workplace environment − electromagnetic field Magnetic field strength in the frequency band: from 800 MHz to 90 GHz (calculated) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
10 Environment – electromagnetic field in the vicinity of power installations Electric field strength:
in the frequency range from 50 Hz Range (100 – 50 000) V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
11 Environment – electromagnetic field in the vicinity of power installations Magnetic flux density
in the frequency range 50 Hz Range (0,05 - 19 000) μT Magnetic field strength (calculated).
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
12 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Electric field strength:
in the frequency range from 100 kHz do 3 GHz Range (0,5 - 1250) V/m in the frequency range from 80 MHz do 90 GHz Range (0,5 - 300) V/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
13 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength:
in the frequency range from 300 kHz do 1 GHz Range (0,01 - 12,0) A/m
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
14 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength in the frequency band: from 300 MHz to 90 GHz (calculated) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
15 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Power density in the frequency band: from 300 MHz – 3 GHz (calculated) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
16 Environment – electromagnetic field in the vicinity of radiocommunication installations: - selective measurements Electric field strength:
in the frequency range from 420 MHz do 6 GHz Range (0,01 - 200) V/m Magnetic field strength in the frequency band: from 420 MHz do 6 GHz (calculated)
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
17 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (43 - 115) dB C-weighted peak sound pressure level Range (43 - 137) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11
18 Workplace environment - noise Noise exposure level referred to:
8-h daily working time -average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11
19 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (24 - 137) dB
Direct measurement method Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) – z wyłączeniem pkt. E.II.1 i F
20 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound level for the reference time T expressed by the index LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) – z wyłączeniem pkt. E.II.1 i F
21 Workplace environment − whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,02 - 17,8) m/s2
Direct measurement method PN-EN 14253+A1:2011
22 Workplace environment − whole-body vibration Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy , awz), Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy , awz ) (calculated) PN-EN 14253+A1:2011
23 Workplace environment − hand-arm vibration Weighted r.m.s. values
frequency-weighted acceleration vibration Range (0,06 - 100) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
24 Workplace environment − hand-arm vibration Daily exposure, expressed as the energy-equivalent value for an 8-hour working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (awx, awy, awz), Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (awx, awy, awz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
25 General environment – noise from high-voltage power lines A-weighted equivalent sound pressure level
Range (24,0 – 137,0) dB
Direct measurement method Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023, poz. 1706) – z wyłączeniem pkt. E.II.1 i F | PN-N 01339:2000
26 General environment – noise from high-voltage power lines A-weighted equivalent sound level for the reference time T expressed by the indicators LAeqD and L AAeqN, Long-term equivalent A-weighted sound level expressed by the indicators, LAeq,LTd and LAeq,LTn (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023, poz. 1706) – z wyłączeniem pkt. E.II.1 i F | PN-N 01339:2000
27 Workplace environment - non-laser optical radiation Effective irradiance of hazardous ultraviolet in the spectral range 180 - 400 nm, Measurement range: 8*10 -4 - 10 [W/m2] Direct measurement method (method A) PN-EN 14255-1:2010
28 Workplace environment - non-laser optical radiation Effective irradiation of hazardous ultraviolet in the spectral range 180 - 400 nm (calculated) PN-EN 14255-1:2010
29 Workplace environment - non-laser optical radiation Irradiance of UVA radiation in the spectral range 315 - 390 nm, Measurement range: 2*10 -4 - 2*103 [W/m2] Direct measurement method (method M) PN-EN 14255-1:2010
30 Workplace environment - non-laser optical radiation Radiant exposure of UVA radiation in the spectral range 315 - 390 nm (calculated) PN-EN 14255-1:2010
31 Workplace environment - non-laser optical radiation Effective irradiance in the spectral range 305 - 700 nm, Measurement range: 2*10-4 - 3*103 [W/m2] Direct measurement method (method O) PN-EN 14255-2:2010
32 Workplace environment - non-laser optical radiation Irradiance in the spectral range 770 - 3000 nm, Measurement range: 9*10-1 - 4*103 [W/m2] Direct measurement method (method R) PN-EN 14255-2:2010
33 Workplace environment - non-laser optical radiation Effective radiance of visible radiation in the spectral range 305 - 700 nm, Measurement range: 1,4*10-3 - 2,78*104 [W/m2*sr] Direct measurement method (method D) PN-EN 14255-2:2010
34 Workplace environment - non-laser optical radiation Effective radiance of radiation in the spectral range 380 - 1400 nm, Measurement range: 2*10-3 - 2*106 [W/m2*sr] Direct measurement method (method A) PN-EN 14255-2:2010
35 Workplace environment - non-laser optical radiation Effective radiance of radiation in the spectral range 780 - 1400 nm, Measurement range: 2,75*10-3 - 2,75*106 [W/m2*sr] Direct measurement method (method U) PN-EN 14255-2:2010
36 Workplace environment - non-laser optical radiation Irradiance in the spectral range 380 - 3000 nm, Measurement range: 9*10-1 - 4*103 [W/m2] Direct measurement method (method X) PN-EN 14255-2:2010
37 Workplace environment - non-laser optical radiation Radiant exposure of radiation in the spectral range 380 - 3000 nm (calculated) PN-EN 14255-2:2010
38 Workstations equipped with devices emitting laser radiation Power of laser radiation generated by laser devices
Range of laser radiation wavelengths: 0,19 - 10,6 [μm] Range of radiation power laser 100 μW - 700 W
Direct measurement method PN-EN ISO 11554:2010 | PN-EN ISO 11554:2018-01
39 Workstations equipped with devices emitting laser radiation Laser pulse energy: Measuring range: − 20 nJ – 20 μJ in the radiation wavelength range λ = (0,19 – 1,1) μm, − 8 μJ – 10 J in the radiation wavelength range λ = (0,15 – 3,0) μm, − 1 mJ – 30 J in the radiation wavelength range λ = (0,19 – 10,6) μm, − 120 mJ – 300 J in the radiation wavelength range λ = (0,19 – 10,6) μm, Direct measurement method PN-EN ISO 11554:2010 | PN-EN ISO 11554:2018-01
40 Equipment used in general analogue radiography Specialist tests Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/1.8 z dnia 18.05.2018 r.
41 Equipment used in general digital radiography Specialist tests Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/1.8 z dnia 18.05.2018 r.
42 Dental equipment – panoramic radiography and digital cephalometry units Specialist tests Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/3.6 z dnia 18.05.2018 r.
43 Equipment used in dentistry – units for intra oral radiography Specialist tests Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/2.7 z dnia 18.05.2018 r.
44 Equipment used in dental cone beam computed tomography Specialist tests Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/3.6 z dnia 18.05.2018 r. Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/3.6 z dnia 18.05.2018 r.
45 Equipment used in fluoroscopy and angiography Specialist tests Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/5.9 z dnia 17.03.2025 r.
46 Equipment used in digital mammography Specialist tests Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/4.8 z dnia 26.06.2023 r.
47 Equipment used in computed tomography Specialist tests Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/8.3 z dnia 18.05.2018 r.
48 Monitors used for the display of medical images Specialist tests Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/9.4 z dnia 18.05.2018 r.
49 Workplace environment – ionising radiation Dose rate in the vicinity of the X-ray apparatus
Range 10 nSv/h – 100 mSv/h Direct measurement
PB/J/6.4 z dnia 20.05.2021 r.
50 General environment – ionising radiation Dose rate in the vicinity of the X-ray apparatus
Range 10 nSv/h – 100 mSv/h Direct measurement
PB/J/6.4 z dnia 20.05.2021 r.

Reference standards (27)

PB/J/6.4 z dnia 20.05.2021 r.
PN-EN 14253+A1:2011
PN-EN 14255-1:2010
PN-EN 14255-2:2010
PN-EN ISO 11554:2010
PN-EN ISO 11554:2018-01
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkt 10 i 11
PN-N 01339:2000
PN-N-01307:1994
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/2.7 z dnia 18.05.2018 r.
Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/3.6 z dnia 18.05.2018 r. Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/3.6 z dnia 18.05.2018 r.
Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/5.9 z dnia 17.03.2025 r.
Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/8.3 z dnia 18.05.2018 r.
Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/1.8 z dnia 18.05.2018 r.
Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/3.6 z dnia 18.05.2018 r.
Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/4.8 z dnia 26.06.2023 r.
Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/J/9.4 z dnia 18.05.2018 r.
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) – z wyłączeniem pkt. E.II.1 i F
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023, poz. 1706) – z wyłączeniem pkt. E.II.1 i F