🇵🇱 HARPER ANALYTICS Sp. z o.o. PL

PCA AB 1981 • Tychy, Poland • 12 methods

Petrochemistry & fuels

HARPER ANALYTICS Sp. z o.o. is a laboratory accredited by PCA under number AB 1981 (Tychy, Poland). Its accreditation scope covers 12 test methods in the following areas: Petrochemistry & fuels. Test objects include: Solid fuels – hard coal. Most frequently used techniques: Gravimetric method, High-temperature combustion with IR detection, Calorimetric method.

At a glance

  • Accreditation number: PCA AB 1981
  • Methods in scope: 12
  • Types of test objects: 1
  • Techniques used: 6
  • City: Tychy, Poland
  • Valid until: 13-10-2030
Accreditation number
AB 1981
Accreditation body
PCA
Address
ul. Dojazdowa 23, 43-100 Tychy
City
Tychy, Poland
Valid until
13-10-2030

What this laboratory tests (1)

Analytical techniques used (6)

Laboratory locations

Certificate information

Issue date
14.10.2026
Issue no.
1

Accreditation scope — test methods (12)

No. Test object Methodology / Parameters Technique Reference document
HARPER ANALYTICS Sp. z o.o.; Testing Laboratory
1 Solid fuels – hard coal Sampling for chemical testing and physical properties PN-ISO 18283:2025-07 pkt. 5.6.5; 5.6.6; 5.6.7 | PN-G-04502:2014-11 pkt. 5.3.3; 5.3.4; 5.3.6
2 Solid fuels – hard coal Total moisture content
Range (1,0 – 30,0) %
Gravimetric method PN-ISO 589:2006 met. B1 | PN-G-04611:2020-06 pkt. 4.4.3
3 Solid fuels – hard coal Moisture content in the analytical sample
Range (0,1 – 10,0) %
Gravimetric method PN-ISO 11722:2009 | PN-G-04611:2020-06 pkt. 4.3.1.3.1
4 Solid fuels – hard coal Ash content
Range (1,0 – 50,0) %
Gravimetric method PN-ISO 1171:2002
5 Solid fuels – hard coal Total sulfur content
Range (0,10 – 2,50) %
High-temperature combustion with IR detection ISO 19579:2006 | PN-G-04584:2001
6 Solid fuels – hard coal Total carbon content
Range (30,0 – 98,0) %
High-temperature combustion with IR detection PKN-ISO/TS 12902:2007 | PN-G-04571:1998
7 Solid fuels – hard coal Hydrogen content
Range (0,10 – 6,00) %
High-temperature combustion with IR detection PKN-ISO/TS 12902:2007 | PN-G-04571:1998
8 Solid fuels – hard coal Nitrogen content
Range (0,10 – 2,00) %
High-temperature combustion with TC detection PKN-ISO/TS 12902:2007 | PN-G-04571:1998
9 Solid fuels – hard coal Gross calorific value
Range (10000 – 35000) kJ/kg Net calorific value (calculated)
Calorimetric method PN-ISO 1928:2020-05
10 Solid fuels – hard coal Volatile matter content
Range (4,00 – 40,00) %
Gravimetric method ISO 562:2024-08 | PN-G-04516:1998
11 Solid fuels – hard coal Chlorine content
Range (0,02 – 0,50) %
Titrimetric method PN-ISO 587:2000 pkt. 7.2.1
12 Solid fuels – hard coal Caking ability
Range 0 - 90
Roga method PN-G-04508:2020-05

Reference standards (16)

ISO 19579:2006
ISO 562:2024-08
PKN-ISO/TS 12902:2007
PN-G-04502:2014-11 pkt. 5.3.3; 5.3.4; 5.3.6
PN-G-04508:2020-05
PN-G-04516:1998
PN-G-04571:1998
PN-G-04584:2001
PN-G-04611:2020-06 pkt. 4.3.1.3.1
PN-G-04611:2020-06 pkt. 4.4.3
PN-ISO 1171:2002
PN-ISO 11722:2009
PN-ISO 18283:2025-07 pkt. 5.6.5; 5.6.6; 5.6.7
PN-ISO 1928:2020-05
PN-ISO 587:2000 pkt. 7.2.1
PN-ISO 589:2006 met. B1

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201981