🇵🇱 QUADRO ENERGY Sp. z o.o. PL

PCA AB 1968 • Krzeszowice, Poland • 11 methods

Water & wastewaterEnvironment

QUADRO ENERGY Sp. z o.o. is a laboratory accredited by PCA under number AB 1968 (Krzeszowice, Poland). Its accreditation scope covers 11 test methods in the following areas: Water & wastewater, Environment. Test objects include: Heat pumps with electrically driven compressors: - air-water with r…, Chillers with electrically driven compressors with rated capacity u…. Most frequently used techniques: Direct heat transfer medium flow measurement method; Liquid enthalp…, Direct measurement method.

At a glance

  • Accreditation number: PCA AB 1968
  • Methods in scope: 11
  • Types of test objects: 2
  • Techniques used: 2
  • City: Krzeszowice, Poland
  • Valid until: 27-04-2030
Accreditation number
AB 1968
Accreditation body
PCA
Address
ul. Krakowska 17, Nawojowa Góra, 32-065 Krzeszowice
City
Krzeszowice, Poland
Valid until
27-04-2030

What this laboratory tests (2)

Analytical techniques used (2)

Certificate information

Issue date
13.05.2026
Issue no.
2

Accreditation scope — test methods (11)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Heat pumps with electrically driven compressors: - air-water with rated capacity up to 100 kW, - water-water with rated capacity up to 200 kW, - brine-water with rated capacity up to 200 kW for space heating and cooling Heating / cooling capacity
Range (0-200) kW
Direct heat transfer medium flow measurement method; Liquid enthalpy method PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1 | PN-EN 14511-4:2023-02 | PN-EN 14825:2022-11 p. 11 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt. 4.1.1 | EN 14511-4:2022 | EN 14825:2022 pt. 11
2 Heat pumps with electrically driven compressors: - air-water with rated capacity up to 100 kW, - water-water with rated capacity up to 200 kW, - brine-water with rated capacity up to 200 kW for space heating and cooling Electric power input
Range (0-49,5) kW
Direct measurement method PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1 | PN-EN 14511-4:2023-02 | PN-EN 14825:2022-11 p. 11; 12 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt. 4.1.1 | EN 14511-4:2022 | EN 14825:2022 pt. 11; 12
3 Heat pumps with electrically driven compressors: - air-water with rated capacity up to 100 kW, - water-water with rated capacity up to 200 kW, - brine-water with rated capacity up to 200 kW for space heating and cooling Coefficient of Performance COP (calculated) PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1 | PN-EN 14511-4:2023-02 | PN-EN 14825:2022-11 p. 11 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt. 4.1.1 | EN 14511-4:2022 | EN 14825:2022 pt. 11
4 Heat pumps with electrically driven compressors: - air-water with rated capacity up to 100 kW, - water-water with rated capacity up to 200 kW, - brine-water with rated capacity up to 200 kW for space heating and cooling Energy efficiency ratio EER (calculated) PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1 | PN-EN 14511-4:2023-02 | PN-EN 14825:2022-11 p. 11 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt. 4.1.1 | EN 14511-4:2022 | EN 14825:2022 pt. 11
5 Heat pumps with electrically driven compressors: - air-water with rated capacity up to 100 kW, - water-water with rated capacity up to 200 kW, - brine-water with rated capacity up to 200 kW for space heating and cooling Seasonal coefficient of performance SCOP (calculated) PN-EN 14825:2022-11 p. 7 | EN 14825:2022 p. 7
6 Heat pumps with electrically driven compressors: - air-water with rated capacity up to 100 kW, - water-water with rated capacity up to 200 kW, - brine-water with rated capacity up to 200 kW for space heating and cooling Seasonal space heating energy efficiency ηs,h (calculated) PN-EN 14825:2022-11 p. 7 | EN 14825:2022 p. 7
7 Heat pumps with electrically driven compressors: - air-water with rated capacity up to 100 kW, - water-water with rated capacity up to 200 kW, - brine-water with rated capacity up to 200 kW for space heating and cooling Seasonal energy efficiency ratio SEER (calculated). PN-EN 14825:2022-11 p. 5 | EN 14825:2022 p. 5
8 Chillers with electrically driven compressors with rated capacity up to 100 kW Cooling capacity
Range (0-100) kW
Direct heat transfer medium flow measurement method; Liquid enthalpy method PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1 | PN-EN 14511-4:2023-02 | PN-EN 14825:2022-11 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt. 4.1.1 | EN 14511-4:2022 | EN 14825:2022
9 Chillers with electrically driven compressors with rated capacity up to 100 kW Electric power input
Range (0-49,5) kW
Direct measurement method PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1 | PN-EN 14511-4:2023-02 | PN-EN 14825:2022-11 p. 11; 12 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt. 4.1.1 | EN 14511-4:2022 | EN 14825:2022 pt. 11; 12
10 Chillers with electrically driven compressors with rated capacity up to 100 kW Energy efficiency ratio EER (calculated) PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1 | PN-EN 14511-4:2023-02 | PN-EN 14825:2022-11 p. 11 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt. 4.1.1 | EN 14511-4:2022 | EN 14825:2022 pt. 11
11 Chillers with electrically driven compressors with rated capacity up to 100 kW Seasonal energy efficiency ratio SEER (calculated). PN-EN 14825:2022-11 p. 5 | EN 14825:2022 p. 5

Reference standards (16)

EN 14511-2:2022
EN 14511-3:2022 excl. pt. 4.1.1
EN 14511-4:2022
EN 14825:2022
EN 14825:2022 p. 5
EN 14825:2022 p. 7
EN 14825:2022 pt. 11
EN 14825:2022 pt. 11; 12
PN-EN 14511-2:2023-02
PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1
PN-EN 14511-4:2023-02
PN-EN 14825:2022-11
PN-EN 14825:2022-11 p. 11
PN-EN 14825:2022-11 p. 11; 12
PN-EN 14825:2022-11 p. 5
PN-EN 14825:2022-11 p. 7

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201968