🇵🇱 QUADRO ENERGY Sp. z o.o. PL
Water & wastewaterEnvironment
QUADRO ENERGY Sp. z o.o. is a laboratory accredited by PCA under number AB 1968 (Krzeszowice, Poland). Its accreditation scope covers 11 test methods in the following areas: Water & wastewater, Environment. Test objects include: Heat pumps with electrically driven compressors: - air-water with r…, Chillers with electrically driven compressors with rated capacity u…. Most frequently used techniques: Direct heat transfer medium flow measurement method; Liquid enthalp…, Direct measurement method.
At a glance
- Accreditation number: PCA AB 1968
- Methods in scope: 11
- Types of test objects: 2
- Techniques used: 2
- City: Krzeszowice, Poland
- Valid until: 27-04-2030
- Accreditation number
- AB 1968
- Accreditation body
- PCA
- Address
- ul. Krakowska 17, Nawojowa Góra, 32-065 Krzeszowice
- City
- Krzeszowice, Poland
- Valid until
- 27-04-2030
What this laboratory tests (2)
- Heat pumps with electrically driven compressors: - air-water with rated capacity up to 100 kW, - water-water with rated capacity up to 200 kW, - brine-water with rated capacity up to 200 kW for space heating and cooling — 7 methods
- Chillers with electrically driven compressors with rated capacity up to 100 kW — 4 methods
Analytical techniques used (2)
- Direct heat transfer medium flow measurement method; Liquid enthalpy method — 2 methods
- Direct measurement method — 2 methods
Certificate information
- Issue date
- 13.05.2026
- Issue no.
- 2
Accreditation scope — test methods (11)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Heat pumps with electrically driven compressors: - air-water with rated capacity up to 100 kW, - water-water with rated capacity up to 200 kW, - brine-water with rated capacity up to 200 kW for space heating and cooling | Heating / cooling capacity Range (0-200) kW |
Direct heat transfer medium flow measurement method; Liquid enthalpy method | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1 | PN-EN 14511-4:2023-02 | PN-EN 14825:2022-11 p. 11 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt. 4.1.1 | EN 14511-4:2022 | EN 14825:2022 pt. 11 | |
| 2 | Heat pumps with electrically driven compressors: - air-water with rated capacity up to 100 kW, - water-water with rated capacity up to 200 kW, - brine-water with rated capacity up to 200 kW for space heating and cooling | Electric power input Range (0-49,5) kW |
Direct measurement method | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1 | PN-EN 14511-4:2023-02 | PN-EN 14825:2022-11 p. 11; 12 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt. 4.1.1 | EN 14511-4:2022 | EN 14825:2022 pt. 11; 12 | |
| 3 | Heat pumps with electrically driven compressors: - air-water with rated capacity up to 100 kW, - water-water with rated capacity up to 200 kW, - brine-water with rated capacity up to 200 kW for space heating and cooling | Coefficient of Performance COP (calculated) | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1 | PN-EN 14511-4:2023-02 | PN-EN 14825:2022-11 p. 11 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt. 4.1.1 | EN 14511-4:2022 | EN 14825:2022 pt. 11 | ||
| 4 | Heat pumps with electrically driven compressors: - air-water with rated capacity up to 100 kW, - water-water with rated capacity up to 200 kW, - brine-water with rated capacity up to 200 kW for space heating and cooling | Energy efficiency ratio EER (calculated) | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1 | PN-EN 14511-4:2023-02 | PN-EN 14825:2022-11 p. 11 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt. 4.1.1 | EN 14511-4:2022 | EN 14825:2022 pt. 11 | ||
| 5 | Heat pumps with electrically driven compressors: - air-water with rated capacity up to 100 kW, - water-water with rated capacity up to 200 kW, - brine-water with rated capacity up to 200 kW for space heating and cooling | Seasonal coefficient of performance SCOP (calculated) | PN-EN 14825:2022-11 p. 7 | EN 14825:2022 p. 7 | ||
| 6 | Heat pumps with electrically driven compressors: - air-water with rated capacity up to 100 kW, - water-water with rated capacity up to 200 kW, - brine-water with rated capacity up to 200 kW for space heating and cooling | Seasonal space heating energy efficiency ηs,h (calculated) | PN-EN 14825:2022-11 p. 7 | EN 14825:2022 p. 7 | ||
| 7 | Heat pumps with electrically driven compressors: - air-water with rated capacity up to 100 kW, - water-water with rated capacity up to 200 kW, - brine-water with rated capacity up to 200 kW for space heating and cooling | Seasonal energy efficiency ratio SEER (calculated). | PN-EN 14825:2022-11 p. 5 | EN 14825:2022 p. 5 | ||
| 8 | Chillers with electrically driven compressors with rated capacity up to 100 kW | Cooling capacity Range (0-100) kW |
Direct heat transfer medium flow measurement method; Liquid enthalpy method | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1 | PN-EN 14511-4:2023-02 | PN-EN 14825:2022-11 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt. 4.1.1 | EN 14511-4:2022 | EN 14825:2022 | |
| 9 | Chillers with electrically driven compressors with rated capacity up to 100 kW | Electric power input Range (0-49,5) kW |
Direct measurement method | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1 | PN-EN 14511-4:2023-02 | PN-EN 14825:2022-11 p. 11; 12 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt. 4.1.1 | EN 14511-4:2022 | EN 14825:2022 pt. 11; 12 | |
| 10 | Chillers with electrically driven compressors with rated capacity up to 100 kW | Energy efficiency ratio EER (calculated) | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1 | PN-EN 14511-4:2023-02 | PN-EN 14825:2022-11 p. 11 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt. 4.1.1 | EN 14511-4:2022 | EN 14825:2022 pt. 11 | ||
| 11 | Chillers with electrically driven compressors with rated capacity up to 100 kW | Seasonal energy efficiency ratio SEER (calculated). | PN-EN 14825:2022-11 p. 5 | EN 14825:2022 p. 5 | ||
Reference standards (16)
EN 14511-2:2022
EN 14511-3:2022 excl. pt. 4.1.1
EN 14511-4:2022
EN 14825:2022
EN 14825:2022 p. 5
EN 14825:2022 p. 7
EN 14825:2022 pt. 11
EN 14825:2022 pt. 11; 12
PN-EN 14511-2:2023-02
PN-EN 14511-3:2023-02 z wyłączeniem punktu 4.1.1
PN-EN 14511-4:2023-02
PN-EN 14825:2022-11
PN-EN 14825:2022-11 p. 11
PN-EN 14825:2022-11 p. 11; 12
PN-EN 14825:2022-11 p. 5
PN-EN 14825:2022-11 p. 7