🇵🇱 Przedsiębiorstwo Produkcyjno Handlowo Usługowe ABB plus Jacek Kujawa PL
Environment
Przedsiębiorstwo Produkcyjno Handlowo Usługowe ABB plus Jacek Kujawa is a laboratory accredited by PCA under number AB 1961 (Płock, Poland). Its accreditation scope covers 8 test methods in the following areas: Environment. Test objects include: Workplace environment - air, General environment – noise from installations, equipment and indus…, Workplace environment – noise. Most frequently used techniques: Direct measurement method, Gravimetric method, Individual dosimetry method; Individual dosimetry method.
At a glance
- Accreditation number: PCA AB 1961
- Methods in scope: 8
- Types of test objects: 3
- Techniques used: 3
- City: Płock, Poland
- Valid until: 22-03-2030
- Accreditation number
- AB 1961
- Accreditation body
- PCA
- Address
- ul. Otolińska (budynek firmy SERWKOMB s.c.) 25, 09-407 Płock
- City
- Płock, Poland
- Valid until
- 22-03-2030
What this laboratory tests (3)
- Workplace environment - air — 4 methods
- General environment – noise from installations, equipment and industrial plants — 2 methods
- Workplace environment – noise — 2 methods
Analytical techniques used (3)
- Direct measurement method — 2 methods
- Gravimetric method — 2 methods
- Individual dosimetry method; Individual dosimetry method — 1 method
Laboratory locations
- Przedsiębiorstwo Produkcyjno Handlowo Usługowe ABB plus Jacek Kujawa (main site) — ul. Mikołaja Kopernika 5/12, 09-500 Gostynin
- Laboratory (building of SERWKOMB s.c.) — ul. Otolińska 25, 09-407 Płock
Certificate information
- Issue date
- 23.03.2026
- Issue no.
- 1
Accreditation scope — test methods (8)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment - air | Sampling for the assessment of occupational exposure to: dust agents inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction metals and their compounds, including inhalable fraction respirable fraction |
Individual dosimetry method; Individual dosimetry method | PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 | |
| 2 | Workplace environment - air | Exposure index (calculated) | PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 | ||
| 3 | Workplace environment - air | Concentration of harmful dust agents - inhalable fraction: Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,19– 17,0) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 4 | Workplace environment - air | Concentration of harmful dust agents - respirable fraction: Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,11 – 3,16) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 5 | Workplace environment – noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (35 – 136) dB C-weighted peak sound pressure level Range (35 – 136) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 (z wyłączeniem metody opisującej strategię 2- punkt 10 i strategię 3-punkt 11) | |
| 6 | Workplace environment – noise | Noise exposure level referred to: 8-hour daily working time, the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 (z wyłączeniem metody opisującej strategię 2- punkt 10 i strategię 3-punkt 11) | ||
| 7 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (25 – 135) dB |
Direct measurement method | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706) z wyłączeniem pkt. EII.1 i F | |
| 8 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706) z wyłączeniem pkt. EII.1 i F | ||
Reference standards (9)
PN-EN ISO 9612:2011 (z wyłączeniem metody opisującej strategię 2- punkt 10 i strategię 3-punkt 11)
PN-N-01307:1994
PN-Z-04008-7:2002
PN-Z-04008-7:2002/Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706) z wyłączeniem pkt. EII.1 i F