🇵🇱 Szkoła Główna Gospodarstwa Wiejskiego w Warszawie PL
Water & wastewaterEnvironment
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie is a laboratory accredited by PCA under number AB 1952 (Warszawa, Poland). Its accreditation scope covers 8 test methods in the following areas: Water & wastewater, Environment. Test objects include: Heat pumps with electrically driven compressors for space heating a…. Most frequently used techniques: Direct heat transfer medium flow measurement method, Direct measurement method.
At a glance
- Accreditation number: PCA AB 1952
- Methods in scope: 8
- Types of test objects: 1
- Techniques used: 2
- City: Warszawa, Poland
- Valid until: 14-12-2029
- Accreditation number
- AB 1952
- Accreditation body
- PCA
- Address
- ul. Nowoursynowska 164, 02-787 Warszawa
- City
- Warszawa, Poland
- Valid until
- 14-12-2029
What this laboratory tests (1)
- Heat pumps with electrically driven compressors for space heating and cooling – type of pumps: - air-to-water - air-to-air - water-to-water (brine) — 8 methods
Analytical techniques used (2)
- Direct heat transfer medium flow measurement method — 1 method
- Direct measurement method — 1 method
Laboratory locations
- Szkoła Główna Gospodarstwa Wiejskiego w Warszawie (main site) — ul. Nowoursynowska 164, 02-787 Warszawa
- LABORATORY OF REFRIGERATION SYSTEMS — ul. Nowoursynowska 164, 02-787 Warszawa
Certificate information
- Issue date
- 19.06.2026
- Issue no.
- 3
Accreditation scope — test methods (8)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| LABORATORY OF REFRIGERATION SYSTEMS | |||||
| 1 | Heat pumps with electrically driven compressors for space heating and cooling – type of pumps: - air-to-water - air-to-air - water-to-water (brine) | Heating / cooling capacity in heating mode (0 – 30) kW in cooling mode (0 – 30) kW In heating mode (0 – 30) kW In cooling mode (0 – 30) kW |
Direct heat transfer medium flow measurement method | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 pkt. 4.1.1; 4.1.2; 4.4; 4.5 | PN-EN 14825:2022-11 pkt 11 | EN 14511-2:2022 | EN 14511-3:2022 p. 4.1.1; 4.1.2; 4.4; 4.5 | EN 14825:2022 p. 11 | |
| 2 | Heat pumps with electrically driven compressors for space heating and cooling – type of pumps: - air-to-water - air-to-air - water-to-water (brine) | Electric power input Range (0 – 23) kW Range (0 – 23) kW |
Direct measurement method | PN-EN 14511-3:2023-02 pkt. 4.1.3; 4.1.4; 4.1.5; 4.1.6; 4.4; 4.5.4 | PN-EN 14825:2022-11 pkt. 11; 12 | EN 14511-3:2022 p. 4.1.3; 4.1.4; 4.1.5; 4.1.6; 4.4; 4.5.4 | EN 14825:2022 p. 11; 12 | |
| 3 | Heat pumps with electrically driven compressors for space heating and cooling – type of pumps: - air-to-water - air-to-air - water-to-water (brine) | Coefficient of Performance COP for heating (calculated) | PN-EN 14511-1:2023-02 pkt 3.6 | EN 14511-1:2022 p. 3.6 | ||
| 4 | Heat pumps with electrically driven compressors for space heating and cooling – type of pumps: - air-to-water - air-to-air - water-to-water (brine) | Energy Efficiency Ratio EER (calculated) | PN-EN 14511-1:2023-02 pkt 3.15 | EN 14511-1:2022 p. 3.15 | ||
| 5 | Heat pumps with electrically driven compressors for space heating and cooling – type of pumps: - air-to-water - air-to-air - water-to-water (brine) | Seasonal Coefficient of Performance SCOP for heating (calculated) | PN-EN 14825:2022-11 pkt 7 | Rozporządzenie Komisji (UE) nr 813/2013 z dnia 02.08.2013 r. | EN 14825:2022 p. 7 | Commission Regulation (EU) No 813/2013 of 2 August 2013 | ||
| 6 | Heat pumps with electrically driven compressors for space heating and cooling – type of pumps: - air-to-water - air-to-air - water-to-water (brine) | Seasonal space heating energy efficiency ηs,h (calculated) | PN-EN 14825:2022-11 pkt 7 | Rozporządzenie Komisji (UE) nr 813/2013 z dnia 02.08.2013 r. | EN 14825:2022 p. 7 | Commission Regulation (EU) No 813/2013 of 2 August 2013 | ||
| 7 | Heat pumps with electrically driven compressors for space heating and cooling – type of pumps: - air-to-water - air-to-air - water-to-water (brine) | Seasonal Energy Efficiency Ratio SEER (calculated) | PN-EN 14825:2022-11 pkt 10 | EN 14825:2022 p. 10 | ||
| 8 | Heat pumps with electrically driven compressors for space heating and cooling – type of pumps: - air-to-water - air-to-air - water-to-water (brine) | Seasonal space cooling energy efficiency ηs,c (calculated) | PN-EN 14825:2022-11 pkt 10 | EN 14825:2022 p. 10 | ||
Reference standards (20)
Commission Regulation (EU) No 813/2013 of 2 August 2013
EN 14511-1:2022 p. 3.15
EN 14511-1:2022 p. 3.6
EN 14511-2:2022
EN 14511-3:2022 p. 4.1.1; 4.1.2; 4.4; 4.5
EN 14511-3:2022 p. 4.1.3; 4.1.4; 4.1.5; 4.1.6; 4.4; 4.5.4
EN 14825:2022 p. 10
EN 14825:2022 p. 11
EN 14825:2022 p. 11; 12
EN 14825:2022 p. 7
PN-EN 14511-1:2023-02 pkt 3.15
PN-EN 14511-1:2023-02 pkt 3.6
PN-EN 14511-2:2023-02
PN-EN 14511-3:2023-02 pkt. 4.1.1; 4.1.2; 4.4; 4.5
PN-EN 14511-3:2023-02 pkt. 4.1.3; 4.1.4; 4.1.5; 4.1.6; 4.4; 4.5.4
PN-EN 14825:2022-11 pkt 10
PN-EN 14825:2022-11 pkt 11
PN-EN 14825:2022-11 pkt 7
PN-EN 14825:2022-11 pkt. 11; 12
Rozporządzenie Komisji (UE) nr 813/2013 z dnia 02.08.2013 r.