🇵🇱 AKADEMIA GÓRNICZO-HUTNICZA PL

PCA AB 1944 • Kraków, Poland • 15 methods

Water & wastewaterEnvironment

AKADEMIA GÓRNICZO-HUTNICZA is a laboratory accredited by PCA under number AB 1944 (Kraków, Poland). Its accreditation scope covers 15 test methods in the following areas: Water & wastewater, Environment. Test objects include: Air-to-water heat pumps with electrically driven compressors for sp…, Air-to-water heat pumps with electrically driven compressors for sp…. Most frequently used techniques: Direct measurement method, Liquid enthalpy method.

At a glance

  • Accreditation number: PCA AB 1944
  • Methods in scope: 15
  • Types of test objects: 2
  • Techniques used: 2
  • City: Kraków, Poland
Accreditation number
AB 1944
Accreditation body
PCA
Address
IM. STANISŁAWA STASZICA W KRAKOWIE, WYDZIAŁ GEOLOGII, GEOFIZYKI I OCHRONY ŚRODOWISKA, al. Mickiewicza 30
City
Kraków, Poland

What this laboratory tests (2)

Analytical techniques used (2)

Laboratory sections (2)

Laboratory locations

Certificate information

Issue date
12.08.2026
Issue no.
2

Accreditation scope — test methods (15)

No. Test object Methodology / Parameters Technique Reference document
Renewable Energy Sources and Energy Conservation Educational and Research Laboratory, Miękinia 381, 32-065 Krzeszowice
1 Air-to-water heat pumps with electrically driven compressors for space heating and cooling Heating capacity
Range: in heating mode (2 – 58) kW
Regulated area: Tests of physical properties of machinery and devices
Liquid enthalpy method PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem pkt. 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 z wyłączeniem pkt. 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022 | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 excl. pt 4.1.2. | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022
2 Air-to-water heat pumps with electrically driven compressors for space heating and cooling Electric power input
Range (0,01 – 34,5) kW Range (0.01 – 34.5) kW
Regulated area: Tests of physical properties of machinery and devices
Direct measurement method PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem pkt. 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 z wyłączeniem pkt. 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022 | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 excl. pt 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022
3 Air-to-water heat pumps with electrically driven compressors for space heating and cooling Coefficient of performance COP for heating (calculated)
Regulated area: Tests of physical properties of machinery and devices
PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem pkt. 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 z wyłączeniem pkt. 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022 | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 excl. pt 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022
4 Air-to-water heat pumps with electrically driven compressors for space heating and cooling Seasonal coefficient of performance SCOP for heating (calculated)
Regulated area: Tests of physical properties of machinery and devices
PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem pkt. 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 z wyłączeniem pkt. 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022 | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 excl. pt 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022
5 Air-to-water heat pumps with electrically driven compressors for space heating and cooling Seasonal space heating energy efficiency ηs,h (calculated)
Regulated area: Tests of physical properties of machinery and devices
PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem pkt. 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 z wyłączeniem pkt. 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022 | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 excl. pt 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022
6 Air-to-water heat pumps with electrically driven compressors for space heating and cooling with dimensions up to 2,2 m A-weighted sound pressure level; Sound pressure level in octave bands
Range (125 – 8000) Hz Range (125 – 8,000) Hz Range (26 – 135) dB
Regulated area: Acoustic and vibration tests of machinery and devices
Direct measurement method PN-EN 12102-1:2022-12 Klasa B | PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3 | EN 12102-1:2022-12 Class B | EN ISO 3744:2011 excl. pt 8.3
7 Air-to-water heat pumps with electrically driven compressors for space heating and cooling with dimensions up to 2,2 m Sound power level; Sound power level in octave bands (calculated)
Regulated area: Acoustic and vibration tests of machinery and devices
PN-EN 12102-1:2022-12 Klasa B | PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3 | EN 12102-1:2022-12 Class B | EN ISO 3744:2011 excl. pt 8.3
Testing Laboratories Team of the Centre for Sustainable Development and Energy Conservation, Miękinia, Miękinia 459, 32-065 Krzeszowice
8 Air-to-water heat pumps with electrically driven compressors for space heating and cooling Heating / cooling capacity
Range: in heating mode (1 – 23) kW Range: In cooling mode (1 – 23) kW
Regulated area: Tests of physical properties of machinery and devices
Liquid enthalpy method PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem pkt. 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 z wyłączeniem pkt. 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022 | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 excl. pt 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022
9 Air-to-water heat pumps with electrically driven compressors for space heating and cooling Electric power input
Range (0,002 – 10,4) kW Range (0,002 – 10,4) kW
Regulated area: Tests of physical properties of machinery and devices
Direct measurement method PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem pkt. 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 z wyłączeniem pkt. 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022 | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 excl. pt 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022
10 Air-to-water heat pumps with electrically driven compressors for space heating and cooling Coefficient of performance COP for heating (calculated)
Regulated area: Tests of physical properties of machinery and devices
PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem pkt. 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 z wyłączeniem pkt. 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022 | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 excl. pt 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022
11 Air-to-water heat pumps with electrically driven compressors for space heating and cooling Energy Efficiency Ratio EER for cooling (calculated)
Regulated area: Tests of physical properties of machinery and devices
PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem pkt. 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 z wyłączeniem pkt. 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022 | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 excl. pt 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022
12 Air-to-water heat pumps with electrically driven compressors for space heating and cooling Seasonal coefficient of performance SCOP for heating (calculated)
Regulated area: Tests of physical properties of machinery and devices
PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem pkt. 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 z wyłączeniem pkt. 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022 | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 excl. pt 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022
13 Air-to-water heat pumps with electrically driven compressors for space heating and cooling Seasonal energy efficiency ratio SEER (calculated)
Regulated area: Tests of physical properties of machinery and devices
PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem pkt. 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 z wyłączeniem pkt. 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022 | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 excl. pt 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022
14 Air-to-water heat pumps with electrically driven compressors for space heating and cooling Seasonal space heating energy efficiency ηs,h (calculated)
Regulated area: Tests of physical properties of machinery and devices
PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem pkt. 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 z wyłączeniem pkt. 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022 | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 excl. pt 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022
15 Air-to-water heat pumps with electrically driven compressors for space heating and cooling Seasonal space cooling energy efficiency ηs,c (calculated)
Regulated area: Tests of physical properties of machinery and devices
PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 z wyłączeniem pkt. 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 z wyłączeniem pkt. 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022 | PN-EN 14511-2:2023-02 | PN-EN 14511-3:2023-02 excl. pt 4.1.2 | PN-EN 14511-4:2023-02 | EN 14511-2:2022 | EN 14511-3:2022 excl. pt 4.1.2 | EN 14511-4:2022 | PN-EN 14825:2022-11 | EN 14825:2022

Reference standards (15)

EN 12102-1:2022-12 Class B
EN 14511-2:2022
EN 14511-3:2022 excl. pt 4.1.2
EN 14511-3:2022 z wyłączeniem pkt. 4.1.2
EN 14511-4:2022
EN 14825:2022
EN ISO 3744:2011 excl. pt 8.3
PN-EN 12102-1:2022-12 Klasa B
PN-EN 14511-2:2023-02
PN-EN 14511-3:2023-02 excl. pt 4.1.2
PN-EN 14511-3:2023-02 excl. pt 4.1.2.
PN-EN 14511-3:2023-02 z wyłączeniem pkt. 4.1.2
PN-EN 14511-4:2023-02
PN-EN 14825:2022-11
PN-EN ISO 3744:2011 z wyłączeniem punktu 8.3

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201944