🇵🇱 POLITECHNIKA RZESZOWSKA im. Ignacego Łukasiewicza PL
Electronics & EMC
POLITECHNIKA RZESZOWSKA im. Ignacego Łukasiewicza is a laboratory accredited by PCA under number AB 1925 (Rzeszów, Poland). Its accreditation scope covers 13 test methods in the following areas: Electronics & EMC. Test objects include: Industrial, scientific and medical equipment, Household appliances, electric tools and similar apparatus, Electrical and electronic equipment, Information technology and multimedia equipment.
At a glance
- Accreditation number: PCA AB 1925
- Methods in scope: 13
- Types of test objects: 5
- City: Rzeszów, Poland
- Accreditation number
- AB 1925
- Accreditation body
- PCA
- Address
- Al. Powstańców Warszawy 12, 35-959 Rzeszów, WYDZIAŁ ELEKTROTECHNIKI I INFORMATYKI, Laboratorium Kompatybilności Elektromagnetycznej
- City
- Rzeszów, Poland
What this laboratory tests (5)
- Industrial, scientific and medical equipment — 4 methods
- Household appliances, electric tools and similar apparatus — 3 methods
- Electrical and electronic equipment — 2 methods
- Information technology and multimedia equipment — 2 methods
- Lighting technology equipment — 2 methods
Laboratory locations
- Laboratorium Kompatybilności Elektromagnetycznej EMC — ul. Wincentego Pola 2
- Laboratorium Kompatybilności Elektromagnetycznej EMC im Prof. Włodzimierza Kality — ul. Wincentego Pola 2, 35-021 Rzeszów
Accreditation scope — test methods (13)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Prof. Włodzimierz Kalita Electromagnetic Compatibility EMC Laboratory | |||||
| 1 | Electrical and electronic equipment | Conducted disturbance emission Continuous disturbance voltage Range 9 kHz – 30 MHz |
PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | ||
| 2 | Industrial, scientific and medical equipment | Conducted disturbance emission Continuous disturbance voltage Range 9 kHz – 30 MHz |
PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A2:2021-08 | ||
| 3 | Household appliances, electric tools and similar apparatus | Conducted disturbance emission Continuous disturbance voltage Range 9 kHz – 30 MHz |
PN-EN IEC 55014-1:2021-08 | ||
| 4 | Information technology and multimedia equipment | Conducted disturbance emission Continuous disturbance voltage Range 9 kHz – 30 MHz |
PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A1:2021-05 | ||
| 5 | Lighting technology equipment | Conducted disturbance emission Continuous disturbance voltage Range 9 kHz – 30 MHz |
PN-EN IEC 55015:2019-11 | ||
| 6 | Electrical and electronic equipment | Radiated disturbance emission Electromagnetic field strength Measurement in a SAC chamber Range 30 MHz – 6 GHz |
PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | ||
| 7 | Industrial, scientific and medical equipment | Radiated disturbance emission Electromagnetic field strength Measurement in a SAC chamber Range 30 MHz – 6 GHz |
PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A2:2021-08 | ||
| 8 | Household appliances, electric tools and similar apparatus | Radiated disturbance emission Electromagnetic field strength Measurement in a SAC chamber Range 30 MHz – 6 GHz |
PN-EN IEC 55014-1:2021-08 | ||
| 9 | Information technology and multimedia equipment | Radiated disturbance emission Electromagnetic field strength Measurement in a SAC chamber Range 30 MHz – 6 GHz |
PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A1:2021-05 | ||
| 10 | Lighting technology equipment | Radiated disturbance emission Electromagnetic field strength Measurement in a SAC chamber Range 30 MHz – 6 GHz |
PN-EN IEC 55015:2019-11 | ||
| 11 | Household appliances, electric tools and similar apparatus | Disturbance power Range 30 MHz – 300 MHz |
PN-EN 55016-2-2:2011 | PN-EN IEC 55014-1:2021-08 | ||
| 12 | Industrial, scientific and medical equipment | Conducted emitted disturbances, Current harmonics | PN-EN IEC 61000-3-2:2019-04 | PN-EN IEC 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-12:2012 | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | ||
| 13 | Industrial, scientific and medical equipment | Conducted emitted disturbances, Voltage fluctuations and flicker (flickers) | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN IEC 61000-3-11:2020-01 | PN-EN 61000-4-15:2011 | ||
Reference standards (21)
PN-EN 55011:2016-05
PN-EN 55011:2016-05/A1:2017-06
PN-EN 55011:2016-05/A2:2021-08
PN-EN 55016-2-1:2014-09
PN-EN 55016-2-1:2014-09/A1:2017-12
PN-EN 55016-2-2:2011
PN-EN 55016-2-3:2017-06
PN-EN 55016-2-3:2017-06/A1:2020-01
PN-EN 55032:2015-09
PN-EN 55032:2015-09/A1:2021-05
PN-EN 61000-3-12:2012
PN-EN 61000-3-3:2013-10
PN-EN 61000-3-3:2013-10/A1:2019-10
PN-EN 61000-4-15:2011
PN-EN 61000-4-7:2007
PN-EN 61000-4-7:2007/A1:2011
PN-EN IEC 55014-1:2021-08
PN-EN IEC 55015:2019-11
PN-EN IEC 61000-3-11:2020-01
PN-EN IEC 61000-3-2:2019-04
PN-EN IEC 61000-3-2:2019-04/A1:2021-08