🇵🇱 Eco-BHP Alicja Skoropińska PL

PCA AB 1922 • Gdańsk, Poland • 16 methods

EnvironmentConstructionMaterials & polymers

Eco-BHP Alicja Skoropińska is a laboratory accredited by PCA under number AB 1922 (Gdańsk, Poland). Its accreditation scope covers 16 test methods in the following areas: Environment, Construction, Materials & polymers. Test objects include: Workplace environment – air, Workplace environment – hand-arm vibration, Workplace environment – hot microclimate*, Workplace environment – indoor electric lighting. Most frequently used techniques: Direct measurement method, Gravimetric method, Personal dosimetry method.

At a glance

  • Accreditation number: PCA AB 1922
  • Methods in scope: 16
  • Types of test objects: 7
  • Techniques used: 3
  • City: Gdańsk, Poland
Accreditation number
AB 1922
Accreditation body
PCA
Address
ul. Uphagena 27/612, 80-237 Gdańsk
City
Gdańsk, Poland

What this laboratory tests (7)

Analytical techniques used (3)

Accreditation scope — test methods (16)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (30,0 – 136,0) dB C-weighted peak sound pressure level Range (30,0 – 136,0) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11
2 Workplace environment – noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11
3 Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,32 – 100) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
4 Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent for 8 hours of action vector sum of root-mean-square, frequency-corrected vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz)., Exposure lasting 30 minutes and less, expressed as the vector sum of root-mean-square, frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
5 Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,03 – 25) m/s2
Direct measurement method PN-EN 14253+A1:2011
6 Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
7 Workplace environment – hot microclimate* Air temperature
Range (20 – 60) °C Natural wet bulb temperature Range (20 – 60) °C Black globe temperature Range (20 – 60) °C
Direct measurement method PN-EN ISO 7243:2018-01
8 Workplace environment – hot microclimate* WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01
9 Workplace environment – moderate microclimate Air temperature
Range (10 – 30) °C Black globe temperature Range (10 – 40) °C Air humidity Range (25 – 90) % Air velocity Range (0,15 – 5,0) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04
10 Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04
11 Workplace environment – indoor electric lighting Illuminance
Range (0,5 – 4800) lx
Direct measurement method PN-83/E-04040.03
12 Workplace environment – indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
13 Workplace environment – air Sampling for the assessment of occupational exposure to:
dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction
Personal dosimetry method PN-Z-04008-7:2002 + Az1:2004
14 Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002 + Az1:2004
15 Workplace environment – air Concentration of harmful dust agents - inhalable fraction:
Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,18 – 40,07) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
16 Workplace environment – air Concentration of harmful dust agents - respirable fraction:
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,11 – 15,47) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08

Reference standards (15)

PN-83/E-04040.03
PN-EN 14253+A1:2011
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006+Ap2:2016-04
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11
PN-N-01307:1994
PN-Z-04008-7:2002 + Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08