🇵🇱 PODHALAŃSKIE PRZEDSIĘBIORSTWO KOMUNALNE Sp. z o.o. PL

PCA AB 1911 • Nowy Targ, Poland • 13 methods

Water & wastewater

PODHALAŃSKIE PRZEDSIĘBIORSTWO KOMUNALNE Sp. z o.o. is a laboratory accredited by PCA under number AB 1911 (Nowy Targ, Poland). Its accreditation scope covers 13 test methods in the following areas: Water & wastewater. Test objects include: Water, wastewater, Wastewater, Water. Most frequently used techniques: Spectrophotometric method, Electrochemical method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 1911
  • Methods in scope: 13
  • Types of test objects: 3
  • Techniques used: 6
  • City: Nowy Targ, Poland
Accreditation number
AB 1911
Accreditation body
PCA
Address
Al. Tysiąclecia 35A, 34-400 Nowy Targ, LABORATORIUM BADANIA ŚCIEKÓW
City
Nowy Targ, Poland

What this laboratory tests (3)

Analytical techniques used (6)

Accreditation scope — test methods (13)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water Sampling for chemical and physical testing Temperature of the water sample taken
Range (5,0 – 35,0) °C
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6 | PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13,14, 15 | PN-77/C-04584
2 Water, wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
3 Water, wastewater Total suspended solids (TSS)
Range (2,0 – 20000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
4 Water, wastewater Biochemical oxygen demand − BOD5
Range (0,50 – 6,0) mg/l O2
Electrochemical method P N-EN 1899-2:2002
5 Water, wastewater Biochemical oxygen demand − BOD5
Range (3,0 – 6000) mg/l O2
Electrochemical method P N-EN ISO 5815-1:2019-12
6 Water, wastewater Chemical oxygen demand − COD
Range (6,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
7 Water, wastewater Total nitrogen concentration
Range (5,0 – 1200) mg/l
Spectrophotometric method PB-01 wydanie 4 z dnia 01.07.2024 r. | na podstawie testu kuwetowego HachLange nr LCK 238, nr LCK 338
8 Water, wastewater Total phosphorus concentration
Range (0,10 – 90,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010
9 Wastewater Sampling for chemical and physical testing
Temperature of wastewater/ collected wastewater sample Range (5,0 – 35,0) °C
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
10 Wastewater Ammonium nitrogen concentration
Range (5,0 – 200) mg/l
Titrimetric method PN-ISO 5664:2002
11 Wastewater Nitrite nitrogen concentration
Range (0,013 – 10,0) mg/l Range (0,043 – 32,9) mg/l NO2-
Spectrophotometric method PN-EN 26777:1999
12 Wastewater Chloride concentration
Range (5,00 – 3000) mg/l
Titrimetric method PN-ISO 9297:1994
13 Wastewater Total chromium concentration
Range (0,030 – 10,0) mg/l
Spectrophotometric method PB-02 wydanie 4 z dnia 01.07.2024 r. | na podstawie testu kuwetowego Hach Lange nr LCK 313

Reference standards (17)

P N-EN 1899-2:2002
P N-EN ISO 5815-1:2019-12
PB-01 wydanie 4 z dnia 01.07.2024 r.
PB-02 wydanie 4 z dnia 01.07.2024 r.
PN-77/C-04584
PN-EN 26777:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6
PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13,14, 15
PN-ISO 9297:1994
na podstawie testu kuwetowego Hach Lange nr LCK 313
na podstawie testu kuwetowego HachLange nr LCK 238, nr LCK 338