🇵🇱 PRO-SAFER Bartosz Hejduk PL
EnvironmentConstruction
PRO-SAFER Bartosz Hejduk is a laboratory accredited by PCA under number AB 1884 (Lublin, Poland). Its accreditation scope covers 27 test methods in the following areas: Environment, Construction. Test objects include: Workplace environment - air, Workplace environment – emergency lighting, Workplace environment - energy expenditure, Workplace environment – cold microclimate. Most frequently used techniques: Direct measurement method, Gravimetric method, Electrochemical method.
At a glance
- Accreditation number: PCA AB 1884
- Methods in scope: 27
- Types of test objects: 10
- Techniques used: 4
- City: Lublin, Poland
- Accreditation number
- AB 1884
- Accreditation body
- PCA
- Address
- ul. Marii Curie-Skłodowskiej 8/8, 20-029 Lublin, ul. Tomasza Zana 38, 20-601 Lublin (adres działalności technicznej)
- City
- Lublin, Poland
What this laboratory tests (10)
- Workplace environment - air — 6 methods
- Workplace environment – emergency lighting — 5 methods
- Workplace environment - energy expenditure — 2 methods
- Workplace environment – cold microclimate — 2 methods
- Workplace environment – hand-arm vibration — 2 methods
- Workplace environment – hot microclimate — 2 methods
- Workplace environment – indoor electric lighting — 2 methods
- Workplace environment – moderate microclimate — 2 methods
- Workplace environment – noise — 2 methods
- Workplace environment – whole-body vibration — 2 methods
Analytical techniques used (4)
- Direct measurement method — 11 methods
- Gravimetric method — 2 methods
- Electrochemical method — 1 method
- Personal dosimetry method — 1 method
Accreditation scope — test methods (27)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment - air | Sampling for the assessment of occupational exposure to: dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – inhalable fraction – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 | |
| 2 | Workplace environment - air | Exposure index (calculated) | PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 | ||
| 3 | Workplace environment - air | Concentration of harmful dust agents - inhalable fraction: Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,18 – 21,26) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 4 | Workplace environment - air | Concentration of harmful dust agents - respirable fraction: Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,10 – 9,28) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 5 | Workplace environment - air | Carbon monoxide concentration Range (2.32 – 232) mg/m3 Range (2 – 200) ppm |
Electrochemical method | PB-02 wydanie 3 z 12.06.2025 r. | |
| 6 | Workplace environment - air | Exposure indices (calculated) | PB-02 wydanie 3 z 12.06.2025 r. | ||
| 7 | Workplace environment – noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (40,0 – 137,0) dB C-weighted peak sound pressure level Range (40,0 – 137,0) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 | |
| 8 | Workplace environment – noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 | ||
| 9 | Workplace environment – indoor electric lighting | Illuminance Range (5 – 9800) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 10 | Workplace environment – indoor electric lighting | Illuminance uniformity (calculated), Illuminance uniformity | PN-83/E-04040.03 | ||
| 11 | Workplace environment – emergency lighting | Illuminance Range (0,5 – 100) lx |
Direct measurement method | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.4.3, 4.4.4, 4.4.6, 4.4.7, 5, | |
| 12 | Workplace environment – emergency lighting | Ratio of minimum to maximum illuminance (calculated) | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.4.3, 4.4.4, 4.4.6, 4.4.7, 5, | ||
| 13 | Workplace environment – emergency lighting | Illuminance uniformity for the high-risk zone (calculated) | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.4.3, 4.4.4, 4.4.6, 4.4.7, 5, | ||
| 14 | Workplace environment – emergency lighting | Closing time Range (1 – 80) s |
Direct measurement method | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.4.3, 4.4.4, 4.4.6, 4.4.7, 5, | |
| 15 | Workplace environment – emergency lighting | Operation time Range (1 – 60) min |
Direct measurement method | PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.4.3, 4.4.4, 4.4.6, 4.4.7, 5, | |
| 16 | Workplace environment - energy expenditure | Air flow Range (10 – 60) dm3/min Air temperature Range (0 – 60) 0C |
Direct measurement method | PB-01 wydanie nr 2 z dnia 27.09.2023 r. | |
| 17 | Workplace environment - energy expenditure | Energy expenditure (calculated) | PB-01 wydanie nr 2 z dnia 27.09.2023 r. | ||
| 18 | Workplace environment – hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,32 – 50) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 | |
| 19 | Workplace environment – hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 | ||
| 20 | Workplace environment – whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,032 – 35) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 21 | Workplace environment – whole-body vibration | Daily exposure, expressed as the energy-equivalent for 8 hours of action root-mean-square, frequency-corrected vibration acceleration, dominant among the vibration accelerations determined for the three directional components taking into account the relevant factors (1.4 awx, 1.4 awy, awz), Exposure lasting 30 minutes and less, expressed as the root-mean-square, frequency-weighted vibration acceleration, dominant among the vibration accelerations determined for the three directional components taking into account the relevant factors (1.4 awx, 1.4 awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 22 | Workplace environment – cold microclimate | Air temperature Range (-29,0 – 10,0) °C Black globe temperature Range (-29,0 – 10,0) °C Air humidity Range (25 – 89) % Air velocity Range (0,15 – 5) m/s |
Direct measurement method | PN-EN ISO 11079:2008+Ap1:2013 | |
| 23 | Workplace environment – cold microclimate | tWC index, IREQmin index, IREQneutral index (calculated) | PN-EN ISO 11079:2008+Ap1:2013 | ||
| 24 | Workplace environment – moderate microclimate | Air temperature Range (10,0 – 30,0) °C Black globe temperature Range (10,0 – 40,0) °C Air humidity Range (25 – 89) % Air velocity Range (0,15 – 1,0) m/s |
Direct measurement method | PN-EN ISO 7730:2006+Ap2:2016-04 | |
| 25 | Workplace environment – moderate microclimate | PMV index, PPD index (calculated) | PN-EN ISO 7730:2006+Ap2:2016-04 | ||
| 26 | Workplace environment – hot microclimate | Air temperature Range (20,0 – 60,0) °C Natural wet bulb temperature Range (10,0 – 60,0) °C Black globe temperature Range (20,0 – 60,0) °C |
Direct measurement method | PN-EN ISO 7243:2018-01 | |
| 27 | Workplace environment – hot microclimate | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 | ||
Reference standards (18)
PB-01 wydanie nr 2 z dnia 27.09.2023 r.
PB-02 wydanie 3 z 12.06.2025 r.
PN-83/E-04040.03
PN-EN 14253+A1:2011
PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.4.3, 4.4.4, 4.4.6, 4.4.7, 5,
PN-EN ISO 11079:2008+Ap1:2013
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004+A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006+Ap2:2016-04
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11
PN-N-01307:1994
PN-Z-04008-7:2002
PN-Z-04008-7:2002/Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08