🇵🇱 Politechnika Krakowska im. Tadeusza Kościuszki PL
ConstructionMaterials & polymers
Politechnika Krakowska im. Tadeusza Kościuszki is a laboratory accredited by PCA under number AB 1882 (Kraków, Poland). Its accreditation scope covers 3 test methods in the following areas: Construction, Materials & polymers. Test objects include: Thermal insulation products for buildings and thermal insulation pr…, Plastics, Plastic products. Most frequently used techniques: Method: differential scanning calorimetry (DSC), Method: plate apparatus with a guarded hot plate, Method: test apparatus with guarded cylinders.
At a glance
- Accreditation number: PCA AB 1882
- Methods in scope: 3
- Types of test objects: 2
- Techniques used: 3
- City: Kraków, Poland
- Accreditation number
- AB 1882
- Accreditation body
- PCA
- Address
- Laboratorium Maszyn i Urządzeń Energetycznych, ul. Warszawska 24, 31-155 Kraków
- City
- Kraków, Poland
What this laboratory tests (2)
- Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations — 2 methods
- Plastics, Plastic products — 1 method
Analytical techniques used (3)
- Method: differential scanning calorimetry (DSC) — 1 method
- Method: plate apparatus with a guarded hot plate — 1 method
- Method: test apparatus with guarded cylinders — 1 method
Laboratory locations
- Laboratorium Maszyn i Urządzeń Energetycznych — ul. Warszawska 24
Accreditation scope — test methods (3)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Power Machinery and Equipment Laboratory | |||||
| 1 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations | Thermal resistance and related properties in the steady state thermal conductivity (0,025 do 0,3) W/(mּ·ּK) temperature range (- 4,5 do 65) oC rotary system allowing rotation of the measuring set-up in the range from 0o do 90o |
Method: plate apparatus with a guarded hot plate | PN ISO 8302:1999 | |
| 2 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations | Steady-state heat flow through thermal insulation of pipework thermal conductivity (0,025 do 0,1) W/(mּ·ּK) temperature range: measuring chamber cold side (-15 do 140) oC measuring chamber heated side (20 do 200) oC |
Method: test apparatus with guarded cylinders | PN-EN ISO 8497:1999 | |
| 3 | Plastics, Plastic products | Temperature and enthalpy of melting and crystallisation temperature (35 do 450) oC |
Method: differential scanning calorimetry (DSC) | PN-EN ISO 11357-1:2023-09 | ISO 11357-3:2025 | PN-EN ISO 11357-3:2025-12 | |
Reference standards (5)
ISO 11357-3:2025
PN ISO 8302:1999
PN-EN ISO 11357-1:2023-09
PN-EN ISO 11357-3:2025-12