🇵🇱 Grupa Azoty Zakłady Azotowe „Puławy" S.A. PL
Water & wastewater
Grupa Azoty Zakłady Azotowe „Puławy" S.A. is a laboratory accredited by PCA under number AB 1852 (Puławy, Poland). Its accreditation scope covers 16 test methods in the following areas: Water & wastewater. Test objects include: Surface waters, Wastewater, Surface waters, Wastewater. Most frequently used techniques: Spectrophotometric method, Electrochemical method, Gravimetric method.
At a glance
- Accreditation number: PCA AB 1852
- Methods in scope: 16
- Types of test objects: 3
- Techniques used: 6
- City: Puławy, Poland
- Accreditation number
- AB 1852
- Accreditation body
- PCA
- Address
- Laboratorium Jakości, Aleja Tysiąclecia Państwa Polskiego 13, 24-110 Puławy
- City
- Puławy, Poland
What this laboratory tests (3)
- Surface waters, Wastewater — 14 methods
- Surface waters — 1 method
- Wastewater — 1 method
Analytical techniques used (6)
- Spectrophotometric method — 6 methods
- Electrochemical method — 2 methods
- Gravimetric method — 2 methods
- Titrimetric method — 2 methods
- Manual method; Automatic method — 1 method
- Potentiometric method — 1 method
Accreditation scope — test methods (16)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Surface waters | Sampling for chemical and physical testing Temperature of the water sample taken Range (0,0 – 50) 0C |
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6 | PN-77/C-04584 | ||
| 2 | Wastewater | Sampling for chemical and physical testing Temperature of wastewater / collected wastewater sample Range (0,0 – 50) 0C |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 3 | Surface waters, Wastewater | pH Range (4,0 – 10,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 4 | Surface waters, Wastewater | Chemical oxygen demand COD Range (10 – 500) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 5 | Surface waters, Wastewater | Ammonium nitrogen concentration Range (0,020 – 40) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 6 | Surface waters, Wastewater | Nitrate nitrogen concentration Range (0,04 – 15) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 7 | Surface waters, Wastewater | Nitrite nitrogen concentration Range (0,005 – 10) mg/l |
Spectrophotometric method | PN-EN 26777: 1999 | |
| 8 | Surface waters, Wastewater | Iron concentration Range (0,010 – 10,0) mg/l |
Spectrophotometric method | PN-EN ISO 6332:2001 +Ap1:2016-06 | |
| 9 | Surface waters, Wastewater | Kjeldahl nitrogen concentration Range (1,0 – 50) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 10 | Surface waters, Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 11 | Surface waters, Wastewater | Chloride concentration Range (5,00– 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 12 | Surface waters, Wastewater | Sulfate concentration Range (10 – 200) mg/l |
Gravimetric method | PN-ISO 9280: 2002 | |
| 13 | Surface waters, Wastewater | Total suspended solids (TSS) Range (2,0 – 500) mg/l |
Gravimetric method | PN-EN 872:2007 +Ap1:2007 | |
| 14 | Surface waters, Wastewater | Biochemical oxygen demand BOD5 Range (2,0 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 15 | Surface waters, Wastewater | Biochemical oxygen demand -BOD5 Range (2 – 200) mg/l |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 16 | Surface waters, Wastewater | Total phosphorus concentration Range (0,04-5,00) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt.7+Ap1:2010+Ap.2:2010 | |
Reference standards (17)
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576/08
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777: 1999
PN-EN 872:2007 +Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6332:2001 +Ap1:2016-06
PN-EN ISO 6878:2006 pkt.7+Ap1:2010+Ap.2:2010
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 7150-1:2002
PN-ISO 9280: 2002
PN-ISO 9297:1994