🇵🇱 SIEMENS HEALTHCARE Sp. z o.o. PL
Other
SIEMENS HEALTHCARE Sp. z o.o. is a laboratory accredited by PCA under number AB 1843 (Warszawa, Poland). Its accreditation scope covers 12 test methods in the following areas: Other. Test objects include: Equipment used in computed tomography, Equipment used in fluoroscopy and angiography, Equipment used in general digital radiography, Monitors used for the display of medical images.
At a glance
- Accreditation number: PCA AB 1843
- Methods in scope: 12
- Types of test objects: 6
- City: Warszawa, Poland
- Accreditation number
- AB 1843
- Accreditation body
- PCA
- Address
- ul. Polna 11, 00-633 Warszawa, LABORATORIUM BADAWCZE, ul. Gdańska 4a
- City
- Warszawa, Poland
What this laboratory tests (6)
- Equipment used in computed tomography — 2 methods
- Equipment used in fluoroscopy and angiography — 2 methods
- Equipment used in general digital radiography — 2 methods
- Monitors used for the display of medical images — 2 methods
- Planar scintillation cameras — 2 methods
- SPECT and SPECT/CT cameras — 2 methods
Accreditation scope — test methods (12)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Equipment used in computed tomography | Acceptance tests covering measurements of: HU value image uniformity tube output volume computed tomography dose index (CTDIvol) layer thickness accuracy of high voltage setting repeatability of the high voltage value high voltage value with changing current |
PB-CT wyd. 1 z 06.05.2024 r. | ||
| 2 | Monitors used for the display of medical images | Acceptance tests covering measurements of: uniformity luminance – consistency of maximum luminance between monitors luminance – monitor contrast luminance - greyscale curve |
PB-MON wyd. 1 z 06.05.2024 r. | ||
| 3 | Planar scintillation cameras | Acceptance tests covering measurements of: pixel size system sensitivity |
PB-MN wyd. 1 z 06.05.2024 r. | ||
| 4 | SPECT and SPECT/CT cameras | Acceptance tests covering measurements of: pixel size system sensitivity tomographic spatial resolution in air tomographic uniformity of the system |
PB-MN wyd. 1 z 06.05.2024 r. | ||
| 5 | Equipment used in general digital radiography | Acceptance tests covering measurements of: accuracy of high voltage setting repeatability of the high voltage value high voltage value with changing current − exposure time − half-value layer (HVL) − X-ray tube output − repeatability of X-ray tube output − X-ray tube output value with changing current − X-ray tube output value with changing current-time product − focal spot size − perpendicularity of the X-ray beam axis − coincidence of the centre of the X-ray field with the centre of the resulting image − coincidence of the centre of the X-ray field with the centre of the light field cross − coincidence of the centre of the light field cross with the centre of the resulting image − coincidence of the X-ray radiation field with the field of the resulting image for collimators with automatic field setting − coincidence of the X-ray radiation field with the light field for collimators with manual field setting − illuminance of the light field simulating the X-ray radiation field − assessment of the repeatability of the AEC system − assessment of the AEC system with changing phantom thickness sensitivity of imaging plates (CR systems) |
PB-RO wyd.2 z 25.06.2024 r. | ||
| 6 | Equipment used in fluoroscopy and angiography | Acceptance tests covering measurements of: − accuracy of the high voltage setting − repeatability of the high voltage value − high voltage value with varying tube current − exposure time − half-value layer (HVL) − X-ray tube output − repeatability of the X-ray tube output − X-ray tube output with varying tube current − X-ray tube output with varying current-time product − perpendicularity of the X-ray beam axis − congruence of the centre of the X-ray field with the centre of the resulting image coincidence of the centre of the X-ray field with the centre of the light field cross − coincidence of the centre of the light field cross with the centre of the resulting image − coincidence of the X-ray radiation field with the field of the resulting image for collimators with automatic field setting − coincidence of the X-ray radiation field with the light field for collimators with manual field setting − illuminance of the light field simulating the X-ray radiation field − assessment of the repeatability of the AEC system − assessment of the AEC system with changing phantom thickness − dose rate at the input of the image intensifier/ image receptor/ digital detector − dose rate at the entrance surface of the phantom − high-contrast resolution of the imaging chain − threshold image contrast − coincidence of the X-ray radiation field with the field of view of the image receptor − entrance dose per image at the input of the image intensifier/ image receptor/ digital detector − entrance dose per image at the entrance surface of the phantom |
PB-F wyd. 1 z 06.05.2024 | ||
| 7 | Equipment used in computed tomography | Specialist tests | Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-CT wyd. 1 z 06.05.2024 r. | ||
| 8 | Monitors used for the display of medical images | Specialist tests | Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-MON wyd.1 z 06.05.2024 | ||
| 9 | Planar scintillation cameras | Specialist tests | Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-MN wyd.1 z 06.05.2024 | ||
| 10 | SPECT and SPECT/CT cameras | Specialist tests | Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-MN wyd. 1 z 06.05.2024 | ||
| 11 | Equipment used in general digital radiography | Specialist tests | Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-RO wyd. 2 z 25.06.2024 r. | ||
| 12 | Equipment used in fluoroscopy and angiography | Specialist tests | Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-F wyd. 1 z 06.05.2024 r. | ||
Reference standards (13)
PB-CT wyd. 1 z 06.05.2024 r.
PB-F wyd. 1 z 06.05.2024
PB-F wyd. 1 z 06.05.2024 r.
PB-MN wyd. 1 z 06.05.2024
PB-MN wyd. 1 z 06.05.2024 r.
PB-MN wyd.1 z 06.05.2024
PB-MON wyd. 1 z 06.05.2024 r.
PB-MON wyd.1 z 06.05.2024
PB-RO wyd. 2 z 25.06.2024 r.
PB-RO wyd.2 z 25.06.2024 r.
Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)
Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)
Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)