🇵🇱 BIODRAIN Sp. z o.o. PL
Environment
BIODRAIN Sp. z o.o. is a laboratory accredited by PCA under number AB 1824 (Rzeszów, Poland). Its accreditation scope covers 8 test methods in the following areas: Environment. Test objects include: General environment - gases emitted into the air - waste gases, Indoor spaces – air, Waste gases. Most frequently used techniques: Metoda płuca, Anemometric method; Thermoanemometric method.
At a glance
- Accreditation number: PCA AB 1824
- Methods in scope: 8
- Types of test objects: 3
- Techniques used: 2
- City: Rzeszów, Poland
- Accreditation number
- AB 1824
- Accreditation body
- PCA
- Address
- Laboratorium Badawcze BioDrain, ul. T. Boya Żeleńskiego 12, 35-105 Rzeszów
- City
- Rzeszów, Poland
What this laboratory tests (3)
- General environment - gases emitted into the air - waste gases — 6 methods
- Indoor spaces – air — 1 method
- Waste gases — 1 method
Analytical techniques used (2)
- Metoda płuca — 4 methods
- Anemometric method; Thermoanemometric method — 1 method
Accreditation scope — test methods (8)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | General environment - gases emitted into the air - waste gases | Sampling for testing by dynamic olfactometry from point sources | Metoda płuca | PN-EN 13725:2022-07 z wyłączeniem pkt. 9.1.4.3 | |
| 2 | General environment - gases emitted into the air - waste gases | Sampling for testing by dynamic olfactometry from active area sources | Metoda płuca | PN-EN 13725:2022-07 z wyłączeniem pkt. 9.1.4.3 | |
| 3 | General environment - gases emitted into the air - waste gases | Sampling for testing by dynamic olfactometry from passive area sources | Metoda płuca | VDI 3880:2011 | |
| 4 | General environment - gases emitted into the air - waste gases | Odour emission rate from point and active area sources (calculated) | PN-EN 13725:2022-07 | ||
| 5 | General environment - gases emitted into the air - waste gases | Odour emission rate from passive area sources (calculated) | VDI 3880:2011 | ||
| 6 | General environment - gases emitted into the air - waste gases | Deodorisation efficiency (calculated) | PN-EN 13725:2022-07 | ||
| 7 | Waste gases | Gas volume flow rate Velocity Range (0,7 – 20) m/s Range (0,2 – 9) m/s |
Anemometric method; Thermoanemometric method | PN-EN ISO 16911-1:2013-07 | |
| 8 | Indoor spaces – air | Sampling for testing by dynamic olfactometry from volume sources | Metoda płuca | PN-EN 13725:2022-07 z wyłączeniem pkt. 9.1.4.3 | Instrukcja IR-01-03 wydanie 03 z dnia 30.10.2025 r. | |
Reference standards (5)
Instrukcja IR-01-03 wydanie 03 z dnia 30.10.2025 r.
PN-EN 13725:2022-07
PN-EN 13725:2022-07 z wyłączeniem pkt. 9.1.4.3
PN-EN ISO 16911-1:2013-07
VDI 3880:2011