PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1807 (Wołomin, Poland). Its accreditation scope covers 27 test methods in the following areas: Water & wastewater. Test objects include: Wastewater, Water, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Conductometric method.

At a glance

  • Accreditation number: PCA AB 1807
  • Methods in scope: 27
  • Types of test objects: 2
  • Techniques used: 8
  • City: Wołomin, Poland
Accreditation number
AB 1807
Accreditation body
PCA
Address
ul. Graniczna 1, 05-200 Wołomin, LABORATORIUM KONTROLI JAKOŚCI WODY I ŚCIEKÓW, ul. Krymska 42
City
Wołomin, Poland

What this laboratory tests (2)

Analytical techniques used (8)

Accreditation scope — test methods (27)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water, Water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken
Range (5,0 – 50,0) °C
PN-ISO 5667-5:2017-10 | PN-77/C-04584
2 Water, Water intended for human consumption pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
3 Water, Water intended for human consumption Electrical conductivity
Range (100 − 5000) μS/cm
Conductometric method PN-EN 27888:1999
4 Water, Water intended for human consumption Turbidity
Range (0,20 – 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
5 Water, Water intended for human consumption Colour
Range (3 – 50) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015-06 metoda C
6 Water, Water intended for human consumption Ammonium ion concentration
Range (0,10 – 1,50) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
7 Water, Water intended for human consumption Nitrate concentration
Range (0,40 – 50) mg/l
Spectrophotometric method IB-07 wydanie 02 z dnia 12.09.2022 r. | na podstawie Testu firmy MERCK nr 1.09713
8 Water, Water intended for human consumption Nitrite concentration
Range (0,010 – 0,200) mg/l
Spectrophotometric method PN-EN 26777:1999
9 Water, Water intended for human consumption Manganese concentration
Range (0,020 – 1,00) mg/l
Spectrophotometric method IB-08 wydanie 02 z dnia 12.09.2022 r. | na podstawie Testu firmy MERCK nr 1.14770
10 Water, Water intended for human consumption Iron concentration
Range (0,050 – 10,00) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
11 Water, Water intended for human consumption Aluminium concentration
Range (0,040 – 0,500) mg/l
Spectrophotometric method IB-04 wydanie 03 z dnia 12.09.2022 r. | na podstawie Testu firmy HACH LANGE nr LCK 301
12 Water, Water intended for human consumption Chloride concentration
Range (5,00 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
13 Water, Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (10 – 800) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
14 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (5,0 – 50) °C
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
15 Wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
16 Wastewater Electrical conductivity
Range (100 − 5000) μS/cm
Conductometric method PN-EN 27888:1999
17 Wastewater Ammonium nitrogen concentration
Range (0,500 – 125) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
18 Wastewater Nitrate nitrogen concentration
Range (1,00 – 25,0) mg/l
Spectrophotometric method IB-07 wydanie 02 z dnia 12.09.2022 r. | na podstawie Testu firmy MERCK nr 1.09713
19 Wastewater Nitrite nitrogen concentration
Range (0,050 – 1,00) mg/l
Spectrophotometric method PN-EN 26777:1999
20 Wastewater Kjeldahl nitrogen concentration
Range (4,00 – 250) mg/l
Titrimetric method PN-EN 25663:2001
21 Wastewater Total nitrogen concentration (calculated) IB-05 wydanie 02 z dnia 22.06.2020 r.
22 Wastewater Total phosphorus concentration
Range (0,100 – 100) mg/l
Spectrophotometric method IB-06 wydanie 03 z dnia 18.07.2023 r. | na podstawie Testu firmy HACH LANGE nr LCK 349, nr LCK 350
23 Wastewater Total suspended solids (TSS)
Range (2,0 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
24 Wastewater Chemical oxygen demand − CODCr
Range (10,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
25 Wastewater Biochemical oxygen demand − BOD5
Range (2,0 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
26 Wastewater Biochemical oxygen demand − BOD5
Range (3,0 – 2000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
27 Wastewater Chloride concentration
Range (5,00 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994

Reference standards (26)

IB-04 wydanie 03 z dnia 12.09.2022 r.
IB-05 wydanie 02 z dnia 22.06.2020 r.
IB-06 wydanie 03 z dnia 18.07.2023 r.
IB-07 wydanie 02 z dnia 12.09.2022 r.
IB-08 wydanie 02 z dnia 12.09.2022 r.
PN-77/C-04584
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5815-1:2019-12
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012+Ap1:2015-06 metoda C
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994
na podstawie Testu firmy HACH LANGE nr LCK 301
na podstawie Testu firmy HACH LANGE nr LCK 349, nr LCK 350
na podstawie Testu firmy MERCK nr 1.09713
na podstawie Testu firmy MERCK nr 1.14770