🇵🇱 DR NOWACZYK PL

PCA AB 1774 • Wrocław, Poland • 24 methods

Pharma & cosmeticsEnvironmentMicrobiologyWater & wastewater

DR NOWACZYK is a laboratory accredited by PCA under number AB 1774 (Wrocław, Poland). Its accreditation scope covers 24 test methods in the following areas: Pharma & cosmetics, Environment, Microbiology, Water & wastewater. Test objects include: Cosmetics, Cosmetics, household chemicals, raw materials, semi-finished products, Environmental samples from areas of trade and production of cosmeti…, Environmental samples from areas of trade and production of cosmeti…. Most frequently used techniques: Plate method (pour plate), Culture method with biochemical confirmation, Contact plate method.

At a glance

  • Accreditation number: PCA AB 1774
  • Methods in scope: 24
  • Types of test objects: 9
  • Techniques used: 12
  • City: Wrocław, Poland
Accreditation number
AB 1774
Accreditation body
PCA
Address
CENTRUM BADAŃ I INNOWACJI SP. Z O.O. SP. K., ul. Żmigrodzka 81-83 lok. 205, 51-130 Wrocław
City
Wrocław, Poland

What this laboratory tests (9)

Analytical techniques used (12)

Accreditation scope — test methods (24)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products - air Air sampling for microbiological testing Gravimetric method (sedimentation plates) MB-005.00, rev. 03 z dn. 17.10.2024
2 Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products - air Total viable count Plate method MB-005.00, rev. 03 z dn. 17.10.2024
3 Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products and from other plants with increased hygiene standards - air Air sampling for microbiological testing Volumetric method (impingement) MB-004.00, rev. 03 z dn. 17.10.2024
4 Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products and from other plants with increased hygiene standards - air Total viable count Plate method MB-004.00, rev. 03 z dn. 17.10.2024
5 Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products - swab from a template-delimited surface - swab from a surface not delimited by a template, including hands Sampling for microbiological testing Swab method PN-EN ISO 18593:2018-08
6 Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products - swab from a template-delimited surface - swab from a surface not delimited by a template, including hands Total viable count Plate method (spread plate) MB-003.00, rev. 04 z dn. 17.10.2024
7 Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products - swab from a template-delimited surface - swab from a surface not delimited by a template, including hands Enterobacteriaceae count Plate method (spread plate) MB-003.00, rev. 04 z dn. 17.10.2024
8 Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products – surface imprint Surface sampling for microbiological testing Contact plate method PN-EN ISO 18593:2018-08
9 Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products – surface imprint Total viable count Contact plate method MB-002.00, rev. 03 z dn. 17.10.2024
10 Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products – surface imprint Enterobacteriaceae count Contact plate method MB-002.00, rev. 03 z dn. 17.10.2024
11 Cosmetics Mesophilic aerobic bacteria count Plate method (pour plate) PN-EN ISO 21149:2017-07 + A1:2023-01
12 Cosmetics Yeast and mould count Plate method (pour plate) PN-EN ISO 16212:2017-08 + A1:2023-01
13 Cosmetics Presence of Pseudomonas aeruginosa Culture method with biochemical confirmation PN-EN ISO 22717:2016-01 + A1:2023-03
14 Cosmetics Presence of Staphylococcus aureus Culture method with biochemical confirmation PN-EN ISO 22718:2016-01 + A1:2023-01
15 Cosmetics Presence of Escherichia coli Culture method with biochemical confirmation PN-EN ISO 21150:2016-01 + A1:2023-03
16 Cosmetics Presence of Candida albicans Culture method with biochemical confirmation PN-EN ISO 18416:2016-01 + A1:2023-03
17 Cosmetics Antimicrobial protection efficacy of the product Plate method (pour plate) PN-EN ISO 11930:2019-03 + A1:2023-02
18 Purified water, Water for injections, Water for preparation of extracts Count of aerobic microorganisms Membrane filtration method Ph. Eur.: 04/2024:0008 Ph. Eur.: 04/2024:0169 Ph. Eur.: 04/2012:2249
19 Water intended for human consumption Total viable count at 22 oC Plate method (pour plate) PN-EN ISO 6222:2004
20 Water intended for human consumption Total viable count at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004
21 Cosmetics, household chemicals, raw materials, semi-finished products Determination of pH
Range 2,0 – 12,0
Potentiometric method MA-001.00, rev. 02 z dn. 16.10.2024
22 Cosmetics, household chemicals, raw materials, semi-finished products Determination of pH of 1% and 10% aqueous solutions
Range 2,0 – 12,0
Potentiometric method MA-001.00, rev. 02 z dn. 16.10.2024
23 Cosmetics, household chemicals, raw materials, semi-finished products Dynamic viscosity
Range (100 – 50000) mPa s
Method using a rotational viscometer MA-003.00, rev. 02 z dn. 16.10.2024
24 Cosmetics, household chemicals, food, raw materials, semi-finished products Water activity
Range 0,100 – 0,950
Method for measuring vapour pressure PN-ISO 21807:2005 z wył. pkt. 6.2, 6.9, 6.10, 6.11

Reference standards (17)

MA-001.00, rev. 02 z dn. 16.10.2024
MA-003.00, rev. 02 z dn. 16.10.2024
MB-002.00, rev. 03 z dn. 17.10.2024
MB-003.00, rev. 04 z dn. 17.10.2024
MB-004.00, rev. 03 z dn. 17.10.2024
MB-005.00, rev. 03 z dn. 17.10.2024
PN-EN ISO 11930:2019-03 + A1:2023-02
PN-EN ISO 16212:2017-08 + A1:2023-01
PN-EN ISO 18416:2016-01 + A1:2023-03
PN-EN ISO 18593:2018-08
PN-EN ISO 21149:2017-07 + A1:2023-01
PN-EN ISO 21150:2016-01 + A1:2023-03
PN-EN ISO 22717:2016-01 + A1:2023-03
PN-EN ISO 22718:2016-01 + A1:2023-01
PN-EN ISO 6222:2004
PN-ISO 21807:2005 z wył. pkt. 6.2, 6.9, 6.10, 6.11
Ph. Eur.: 04/2024:0008 Ph. Eur.: 04/2024:0169 Ph. Eur.: 04/2012:2249