🇵🇱 DR NOWACZYK PL
Pharma & cosmeticsEnvironmentMicrobiologyWater & wastewater
DR NOWACZYK is a laboratory accredited by PCA under number AB 1774 (Wrocław, Poland). Its accreditation scope covers 24 test methods in the following areas: Pharma & cosmetics, Environment, Microbiology, Water & wastewater. Test objects include: Cosmetics, Cosmetics, household chemicals, raw materials, semi-finished products, Environmental samples from areas of trade and production of cosmeti…, Environmental samples from areas of trade and production of cosmeti…. Most frequently used techniques: Plate method (pour plate), Culture method with biochemical confirmation, Contact plate method.
At a glance
- Accreditation number: PCA AB 1774
- Methods in scope: 24
- Types of test objects: 9
- Techniques used: 12
- City: Wrocław, Poland
- Accreditation number
- AB 1774
- Accreditation body
- PCA
- Address
- CENTRUM BADAŃ I INNOWACJI SP. Z O.O. SP. K., ul. Żmigrodzka 81-83 lok. 205, 51-130 Wrocław
- City
- Wrocław, Poland
What this laboratory tests (9)
- Cosmetics — 7 methods
- Cosmetics, household chemicals, raw materials, semi-finished products — 3 methods
- Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products - swab from a template-delimited surface - swab from a surface not delimited by a template, including hands — 3 methods
- Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products – surface imprint — 3 methods
- Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products - air — 2 methods
- Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products and from other plants with increased hygiene standards - air — 2 methods
- Water intended for human consumption — 2 methods
- Cosmetics, household chemicals, food, raw materials, semi-finished products — 1 method
- Purified water, Water for injections, Water for preparation of extracts — 1 method
Analytical techniques used (12)
- Plate method (pour plate) — 5 methods
- Culture method with biochemical confirmation — 4 methods
- Contact plate method — 3 methods
- Plate method — 2 methods
- Plate method (spread plate) — 2 methods
- Potentiometric method — 2 methods
- Gravimetric method (sedimentation plates) — 1 method
- Membrane filtration method — 1 method
- Method for measuring vapour pressure — 1 method
- Method using a rotational viscometer — 1 method
- Swab method — 1 method
- Volumetric method (impingement) — 1 method
Accreditation scope — test methods (24)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products - air | Air sampling for microbiological testing | Gravimetric method (sedimentation plates) | MB-005.00, rev. 03 z dn. 17.10.2024 | |
| 2 | Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products - air | Total viable count | Plate method | MB-005.00, rev. 03 z dn. 17.10.2024 | |
| 3 | Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products and from other plants with increased hygiene standards - air | Air sampling for microbiological testing | Volumetric method (impingement) | MB-004.00, rev. 03 z dn. 17.10.2024 | |
| 4 | Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products and from other plants with increased hygiene standards - air | Total viable count | Plate method | MB-004.00, rev. 03 z dn. 17.10.2024 | |
| 5 | Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products - swab from a template-delimited surface - swab from a surface not delimited by a template, including hands | Sampling for microbiological testing | Swab method | PN-EN ISO 18593:2018-08 | |
| 6 | Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products - swab from a template-delimited surface - swab from a surface not delimited by a template, including hands | Total viable count | Plate method (spread plate) | MB-003.00, rev. 04 z dn. 17.10.2024 | |
| 7 | Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products - swab from a template-delimited surface - swab from a surface not delimited by a template, including hands | Enterobacteriaceae count | Plate method (spread plate) | MB-003.00, rev. 04 z dn. 17.10.2024 | |
| 8 | Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products – surface imprint | Surface sampling for microbiological testing | Contact plate method | PN-EN ISO 18593:2018-08 | |
| 9 | Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products – surface imprint | Total viable count | Contact plate method | MB-002.00, rev. 03 z dn. 17.10.2024 | |
| 10 | Environmental samples from areas of trade and production of cosmetics, medical devices and medicinal products – surface imprint | Enterobacteriaceae count | Contact plate method | MB-002.00, rev. 03 z dn. 17.10.2024 | |
| 11 | Cosmetics | Mesophilic aerobic bacteria count | Plate method (pour plate) | PN-EN ISO 21149:2017-07 + A1:2023-01 | |
| 12 | Cosmetics | Yeast and mould count | Plate method (pour plate) | PN-EN ISO 16212:2017-08 + A1:2023-01 | |
| 13 | Cosmetics | Presence of Pseudomonas aeruginosa | Culture method with biochemical confirmation | PN-EN ISO 22717:2016-01 + A1:2023-03 | |
| 14 | Cosmetics | Presence of Staphylococcus aureus | Culture method with biochemical confirmation | PN-EN ISO 22718:2016-01 + A1:2023-01 | |
| 15 | Cosmetics | Presence of Escherichia coli | Culture method with biochemical confirmation | PN-EN ISO 21150:2016-01 + A1:2023-03 | |
| 16 | Cosmetics | Presence of Candida albicans | Culture method with biochemical confirmation | PN-EN ISO 18416:2016-01 + A1:2023-03 | |
| 17 | Cosmetics | Antimicrobial protection efficacy of the product | Plate method (pour plate) | PN-EN ISO 11930:2019-03 + A1:2023-02 | |
| 18 | Purified water, Water for injections, Water for preparation of extracts | Count of aerobic microorganisms | Membrane filtration method | Ph. Eur.: 04/2024:0008 Ph. Eur.: 04/2024:0169 Ph. Eur.: 04/2012:2249 | |
| 19 | Water intended for human consumption | Total viable count at 22 oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 20 | Water intended for human consumption | Total viable count at 36 oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 21 | Cosmetics, household chemicals, raw materials, semi-finished products | Determination of pH Range 2,0 – 12,0 |
Potentiometric method | MA-001.00, rev. 02 z dn. 16.10.2024 | |
| 22 | Cosmetics, household chemicals, raw materials, semi-finished products | Determination of pH of 1% and 10% aqueous solutions Range 2,0 – 12,0 |
Potentiometric method | MA-001.00, rev. 02 z dn. 16.10.2024 | |
| 23 | Cosmetics, household chemicals, raw materials, semi-finished products | Dynamic viscosity Range (100 – 50000) mPa s |
Method using a rotational viscometer | MA-003.00, rev. 02 z dn. 16.10.2024 | |
| 24 | Cosmetics, household chemicals, food, raw materials, semi-finished products | Water activity Range 0,100 – 0,950 |
Method for measuring vapour pressure | PN-ISO 21807:2005 z wył. pkt. 6.2, 6.9, 6.10, 6.11 | |
Reference standards (17)
MA-001.00, rev. 02 z dn. 16.10.2024
MA-003.00, rev. 02 z dn. 16.10.2024
MB-002.00, rev. 03 z dn. 17.10.2024
MB-003.00, rev. 04 z dn. 17.10.2024
MB-004.00, rev. 03 z dn. 17.10.2024
MB-005.00, rev. 03 z dn. 17.10.2024
PN-EN ISO 11930:2019-03 + A1:2023-02
PN-EN ISO 16212:2017-08 + A1:2023-01
PN-EN ISO 18416:2016-01 + A1:2023-03
PN-EN ISO 18593:2018-08
PN-EN ISO 21149:2017-07 + A1:2023-01
PN-EN ISO 21150:2016-01 + A1:2023-03
PN-EN ISO 22717:2016-01 + A1:2023-03
PN-EN ISO 22718:2016-01 + A1:2023-01
PN-EN ISO 6222:2004
PN-ISO 21807:2005 z wył. pkt. 6.2, 6.9, 6.10, 6.11
Ph. Eur.: 04/2024:0008 Ph. Eur.: 04/2024:0169 Ph. Eur.: 04/2012:2249