🇵🇱 UNIWERSYTET GDAŃSKI PL
MicrobiologyWater & wastewater
UNIWERSYTET GDAŃSKI is a laboratory accredited by PCA under number AB 1760 (Gdańsk, Poland). Its accreditation scope covers 8 test methods in the following areas: Microbiology, Water & wastewater. Test objects include: Water, Water intended for human consumption, Plants E. Most frequently used techniques: Membrane filtration method, Plate method (pour plate), Culture method.
At a glance
- Accreditation number: PCA AB 1760
- Methods in scope: 8
- Types of test objects: 2
- Techniques used: 5
- City: Gdańsk, Poland
- Accreditation number
- AB 1760
- Accreditation body
- PCA
- Address
- ul. prof. Marii Janion 7, 80-309 Gdańsk, Międzyuczelniany Wydział Biotechnologii UG i GUMed, Laboratorium Badawczo-Wdrożeniowe, ul. Podwale Przedmiejskie 20, 80-824 Gdańsk
- City
- Gdańsk, Poland
What this laboratory tests (2)
- Water, Water intended for human consumption — 5 methods
- Plants E — 3 methods
Analytical techniques used (5)
- Membrane filtration method — 3 methods
- Plate method (pour plate) — 2 methods
- Culture method — 1 method
- Multiplex PCR method — 1 method
- PCR method — 1 method
Accreditation scope — test methods (8)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water, Water intended for human consumption | Total viable count at 22oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 2 | Water, Water intended for human consumption | Total viable count at 36oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 3 | Water, Water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 4 | Water, Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04 | |
| 5 | Water, Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04 | |
| 6 | Plants E | Presence of bacteria | Culture method | Procedury opracowane przez laboratorium | |
| 7 | Plants E | Presence of bacteria-specific DNA | Multiplex PCR method | Procedury opracowane przez laboratorium | |
| 8 | Plants E | Presence of bacteria-specific DNA | PCR method | Procedury opracowane przez laboratorium | |
Reference standards (5)
PN-EN ISO 6222:2004
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12/ A1:2017-04
Procedury opracowane przez laboratorium