🇵🇱 EKOTECHLAB MAREK KLEIN S.K.A. PL
EnvironmentElectronics & EMC
EKOTECHLAB MAREK KLEIN S.K.A. is a laboratory accredited by PCA under number AB 1755 (Straszyn, Poland). Its accreditation scope covers 4 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Płyny do uzupełniania papierosów elektronicznych E, Saszetki nikotynowe, Surowce zawierające kannabinoidy E; Produkty konopne z dodatkiem ka…, Workplace environment – air samples collected on sorbent tubes. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Gas chromatography coupled with mass spectrometry (GC-MS), High-performance liquid chromatography with diode array detection (….
At a glance
- Accreditation number: PCA AB 1755
- Methods in scope: 4
- Types of test objects: 4
- Techniques used: 3
- City: Straszyn, Poland
- Accreditation number
- AB 1755
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAWCZO-ROZWOJOWE EKOTECHLAB, ul. Jasia i Małgosi 1, 83-010 Straszyn
- City
- Straszyn, Poland
What this laboratory tests (4)
- Płyny do uzupełniania papierosów elektronicznych E — 1 method
- Saszetki nikotynowe — 1 method
- Surowce zawierające kannabinoidy E; Produkty konopne z dodatkiem kannabinoidów E; Produkty z dodatkiem konopi i/lub izolatów/ekstraktów konopnych E — 1 method
- Workplace environment – air samples collected on sorbent tubes — 1 method
Analytical techniques used (3)
- Gas chromatography with flame ionization detection (GC-FID) — 2 methods
- Gas chromatography coupled with mass spectrometry (GC-MS) — 1 method
- High-performance liquid chromatography with diode array detection (HPLC-DAD); High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis) — 1 method
Laboratory locations
- Laboratorium Badawczo-Rozwojowe EkotechLAB — ul. Jasia i Małgosi 1
Accreditation scope — test methods (4)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratorium Badawczo-Rozwojowe EkotechLAB | |||||
| 1 | Workplace environment – air samples collected on sorbent tubes | Content of organic compounds ethyl acetate (1,0 - 2000) μg w próbce 1,2-dichloroethane (1,0 - 2000) μg w próbce chlorobenzene (1,0 - 100) μg w próbce |
Gas chromatography coupled with mass spectrometry (GC-MS) | PB-EL-1:2022 wydanie 5 z dnia 31.01.2025 r. | |
| 2 | Saszetki nikotynowe | Nicotine content Nicotine content (3,00 – 20,0) mg/g |
Gas chromatography with flame ionization detection (GC-FID) | ISO 20714:2019-08 | |
| 3 | Płyny do uzupełniania papierosów elektronicznych E | Zawartość nikotyny; Zawartość glikolu propylenowego; Zawartość gliceryny Nicotine content Propylene glycol content Glycerine content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
Gas chromatography with flame ionization detection (GC-FID) | ISO 20714 | |
| 4 | Surowce zawierające kannabinoidy E; Produkty konopne z dodatkiem kannabinoidów E; Produkty z dodatkiem konopi i/lub izolatów/ekstraktów konopnych E | Cannabinoid content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
High-performance liquid chromatography with diode array detection (HPLC-DAD); High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis) | PB-CL-1 | |
Reference standards (4)
ISO 20714
ISO 20714:2019-08
PB-CL-1